AUTHORSSu-Jin Park, Jaehyuk Kim, Jong Chul Han, Jung-Ha Kim, Jung-Min Kim, Jong-Pil Kim, Minkook Cho, Jung Woo Kim
ABSTRACTPediatric dosimetry requires extra attention as young children are three times more sensitive to radiation than the average population. Soft tissues of patients absorb low-energy photons without affecting useful diagnostic information. X-ray filters can decrease the exposure dose of radiation by removing low-energy photons from the X-ray beam. Several studies have dealt with the advantages of a conventional filter, copper (Cu), in pediatric digital X-ray radiography. Only a few studies, however, have examined the use of molybdenum (Mo) filters and their impact on the radiation dose and image quality in pediatric digital X-ray imaging. In this study, we investigated the impact of a Mo filter on the image quality and the entrance surface exposure (ESE) in pediatric X-ray imaging and assessed the potential of additional dose reduction compared to a conventional Cu filter. The performance of the Mo filter was investigated and compared with that of Cu filter. Two types of phantoms were used: a customized quantitative phantom (Phantom A) for quantitative comparison and a computational anthropomorphic extended cardiac-torso (XCAT) phantom for qualitative comparison. A clinical radiography system was modeled, and the clinical setting for pediatric chest X-ray imaging was considered. Geant4 simulations using Monte Carlo toolkits were performed to obtain the images for pediatric chest X-ray examinations. Quantitative and qualitative comparisons using the quantitative phantom (Phantom A) and the XCAT phantom, respectively, were performed for both filters. From the customized quantitative phantom study, the ESE for the Mo filter was compared with that for the Cu filter when contrast-to-noise ratio (CNR) was equal. In addition, to validate our Monte Carlo model, we compared simulated and experimentally acquired images. From the results, the ESE for the Cu filter was 22.62 μGy while the ESE for the Mo filter was 18.18 μGy for 5-mm soft tissue. The use of a Mo filter results in a reduction in the dose by 19.60%. From the XCAT phantom study, the image for the Mo filter was superior to that for Cu filter in terms of noise and recognition of blood vessels. The performance characteristics of the Mo filter were evaluated in terms of image quality and radiation dose by comparing those characteristics to the ones for a conventional Cu filter. Our results demonstrated that the use of the Mo filter can significantly reduce the radiation dose. Based on this result, Mo filters are recommended for use in pediatric digital X-ray imaging. More... »
PAGES1253-1259
http://scigraph.springernature.com/pub.10.3938/jkps.77.1253
DOIhttp://dx.doi.org/10.3938/jkps.77.1253
DIMENSIONShttps://app.dimensions.ai/details/publication/pub.1132774760
JSON-LD is the canonical representation for SciGraph data.
TIP: You can open this SciGraph record using an external JSON-LD service: JSON-LD Playground Google SDTT
[
{
"@context": "https://springernature.github.io/scigraph/jsonld/sgcontext.json",
"about": [
{
"id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/02",
"inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/",
"name": "Physical Sciences",
"type": "DefinedTerm"
},
{
"id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/0299",
"inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/",
"name": "Other Physical Sciences",
"type": "DefinedTerm"
}
],
"author": [
{
"affiliation": {
"alternateName": "H/W Solution Team, PCD R&D Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 16677, Suwon, Korea",
"id": "http://www.grid.ac/institutes/grid.419666.a",
"name": [
"H/W Solution Team, PCD R&D Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 16677, Suwon, Korea"
],
"type": "Organization"
},
"familyName": "Park",
"givenName": "Su-Jin",
"type": "Person"
},
{
"affiliation": {
"alternateName": "H/W Solution Team, CAE Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 13530, Seongnam, Korea",
"id": "http://www.grid.ac/institutes/grid.419666.a",
"name": [
"H/W Solution Team, CAE Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 13530, Seongnam, Korea"
],
"type": "Organization"
},
"familyName": "Kim",
"givenName": "Jaehyuk",
"id": "sg:person.012035044352.56",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.012035044352.56"
],
"type": "Person"
},
{
"affiliation": {
"alternateName": "DR Business Team, DR R&D Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 16677, Suwon, Korea",
"id": "http://www.grid.ac/institutes/grid.419666.a",
"name": [
"DR Business Team, DR R&D Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 16677, Suwon, Korea"
],
"type": "Organization"
},
"familyName": "Han",
"givenName": "Jong Chul",
"id": "sg:person.010462010223.35",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.010462010223.35"
],
"type": "Person"
},
{
"affiliation": {
"alternateName": "H/W Solution Team, CAE Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 13530, Seongnam, Korea",
"id": "http://www.grid.ac/institutes/grid.419666.a",
"name": [
"H/W Solution Team, CAE Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 13530, Seongnam, Korea"
],
"type": "Organization"
},
"familyName": "Kim",
"givenName": "Jung-Ha",
"type": "Person"
},
{
"affiliation": {
"alternateName": "H/W Solution Team, CAE Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 13530, Seongnam, Korea",
"id": "http://www.grid.ac/institutes/grid.419666.a",
"name": [
"H/W Solution Team, CAE Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 13530, Seongnam, Korea"
],
"type": "Organization"
},
"familyName": "Kim",
"givenName": "Jung-Min",
"type": "Person"
},
{
"affiliation": {
"alternateName": "DR Business Team, DR R&D Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 16677, Suwon, Korea",
"id": "http://www.grid.ac/institutes/grid.419666.a",
"name": [
"DR Business Team, DR R&D Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 16677, Suwon, Korea"
],
"type": "Organization"
},
"familyName": "Kim",
"givenName": "Jong-Pil",
"type": "Person"
},
{
"affiliation": {
"alternateName": "H/W Solution Team, PCD R&D Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 16677, Suwon, Korea",
"id": "http://www.grid.ac/institutes/grid.419666.a",
"name": [
"H/W Solution Team, PCD R&D Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 16677, Suwon, Korea"
],
"type": "Organization"
},
"familyName": "Cho",
"givenName": "Minkook",
"id": "sg:person.07460435466.55",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.07460435466.55"
],
"type": "Person"
},
{
"affiliation": {
"alternateName": "H/W Solution Team, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 13530, Seongnam, Korea",
"id": "http://www.grid.ac/institutes/grid.419666.a",
"name": [
"H/W Solution Team, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 13530, Seongnam, Korea"
],
"type": "Organization"
},
"familyName": "Kim",
"givenName": "Jung Woo",
"type": "Person"
}
],
"citation": [
{
"id": "sg:pub.10.1007/s00247-004-1271-z",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1052373401",
"https://doi.org/10.1007/s00247-004-1271-z"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/s12194-011-0115-4",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1031190353",
"https://doi.org/10.1007/s12194-011-0115-4"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/s00247-004-1268-7",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1035649403",
"https://doi.org/10.1007/s00247-004-1268-7"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1186/s12998-019-0241-3",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1113843614",
"https://doi.org/10.1186/s12998-019-0241-3"
],
"type": "CreativeWork"
}
],
"datePublished": "2020-11-19",
"datePublishedReg": "2020-11-19",
"description": "Pediatric dosimetry requires extra attention as young children are three times more sensitive to radiation than the average population. Soft tissues of patients absorb low-energy photons without affecting useful diagnostic information. X-ray filters can decrease the exposure dose of radiation by removing low-energy photons from the X-ray beam. Several studies have dealt with the advantages of a conventional filter, copper (Cu), in pediatric digital X-ray radiography. Only a few studies, however, have examined the use of molybdenum (Mo) filters and their impact on the radiation dose and image quality in pediatric digital X-ray imaging. In this study, we investigated the impact of a Mo filter on the image quality and the entrance surface exposure (ESE) in pediatric X-ray imaging and assessed the potential of additional dose reduction compared to a conventional Cu filter. The performance of the Mo filter was investigated and compared with that of Cu filter. Two types of phantoms were used: a customized quantitative phantom (Phantom A) for quantitative comparison and a computational anthropomorphic extended cardiac-torso (XCAT) phantom for qualitative comparison. A clinical radiography system was modeled, and the clinical setting for pediatric chest X-ray imaging was considered. Geant4 simulations using Monte Carlo toolkits were performed to obtain the images for pediatric chest X-ray examinations. Quantitative and qualitative comparisons using the quantitative phantom (Phantom A) and the XCAT phantom, respectively, were performed for both filters. From the customized quantitative phantom study, the ESE for the Mo filter was compared with that for the Cu filter when contrast-to-noise ratio (CNR) was equal. In addition, to validate our Monte Carlo model, we compared simulated and experimentally acquired images. From the results, the ESE for the Cu filter was 22.62 \u03bcGy while the ESE for the Mo filter was 18.18 \u03bcGy for 5-mm soft tissue. The use of a Mo filter results in a reduction in the dose by 19.60%. From the XCAT phantom study, the image for the Mo filter was superior to that for Cu filter in terms of noise and recognition of blood vessels. The performance characteristics of the Mo filter were evaluated in terms of image quality and radiation dose by comparing those characteristics to the ones for a conventional Cu filter. Our results demonstrated that the use of the Mo filter can significantly reduce the radiation dose. Based on this result, Mo filters are recommended for use in pediatric digital X-ray imaging.",
"genre": "article",
"id": "sg:pub.10.3938/jkps.77.1253",
"inLanguage": "en",
"isAccessibleForFree": false,
"isPartOf": [
{
"id": "sg:journal.1042000",
"issn": [
"0374-4884",
"1976-8524"
],
"name": "Journal of the Korean Physical Society",
"publisher": "Korean Physical Society",
"type": "Periodical"
},
{
"issueNumber": "12",
"type": "PublicationIssue"
},
{
"type": "PublicationVolume",
"volumeNumber": "77"
}
],
"keywords": [
"digital X-ray imaging",
"X-ray imaging",
"low-energy photons",
"Mo filter",
"Cu filter",
"quantitative phantoms",
"X-ray filters",
"Monte Carlo toolkit",
"X-ray beam",
"entrance surface exposure",
"digital X-ray radiography",
"Monte Carlo model",
"radiation dose",
"X-ray radiography",
"Geant4 simulations",
"molybdenum filter",
"image quality",
"Carlo model",
"phantom study",
"photons",
"pediatric chest X-ray examinations",
"radiography system",
"additional dose reduction",
"dose reduction",
"phantom",
"terms of noise",
"radiation",
"chest X-ray examination",
"cardiac-torso (NCAT) phantom",
"types of phantoms",
"soft tissue",
"noise ratio",
"exposure dose",
"X-ray examination",
"beam",
"imaging",
"qualitative comparison",
"chest X-ray imaging",
"useful diagnostic information",
"quantitative comparison",
"clinical setting",
"XCAT phantom",
"dose",
"blood vessels",
"dosimetry",
"\u03bcGy",
"young children",
"filter",
"diagnostic information",
"images",
"tissue",
"average population",
"patients",
"extra attention",
"simulations",
"filter results",
"study",
"noise",
"radiography",
"children",
"molybdenum",
"reduction",
"examination",
"exposure",
"use of molybdenum",
"use",
"conventional filters",
"performance characteristics",
"vessels",
"results",
"comparison",
"population",
"copper",
"terms",
"setting",
"quality",
"potential",
"ratio",
"surface exposure",
"evaluation",
"characteristics",
"system",
"impact",
"contrast",
"one",
"advantages",
"model",
"time",
"addition",
"toolkit",
"types",
"Simulated",
"anthropomorphic",
"recognition",
"performance",
"information",
"attention"
],
"name": "Evaluation of the Use of a Molybdenum Filter for Dose Reduction in Pediatric Digital X-ray Imaging",
"pagination": "1253-1259",
"productId": [
{
"name": "dimensions_id",
"type": "PropertyValue",
"value": [
"pub.1132774760"
]
},
{
"name": "doi",
"type": "PropertyValue",
"value": [
"10.3938/jkps.77.1253"
]
}
],
"sameAs": [
"https://doi.org/10.3938/jkps.77.1253",
"https://app.dimensions.ai/details/publication/pub.1132774760"
],
"sdDataset": "articles",
"sdDatePublished": "2022-06-01T22:21",
"sdLicense": "https://scigraph.springernature.com/explorer/license/",
"sdPublisher": {
"name": "Springer Nature - SN SciGraph project",
"type": "Organization"
},
"sdSource": "s3://com-springernature-scigraph/baseset/20220601/entities/gbq_results/article/article_871.jsonl",
"type": "ScholarlyArticle",
"url": "https://doi.org/10.3938/jkps.77.1253"
}
]
Download the RDF metadata as: json-ld nt turtle xml License info
JSON-LD is a popular format for linked data which is fully compatible with JSON.
curl -H 'Accept: application/ld+json' 'https://scigraph.springernature.com/pub.10.3938/jkps.77.1253'
N-Triples is a line-based linked data format ideal for batch operations.
curl -H 'Accept: application/n-triples' 'https://scigraph.springernature.com/pub.10.3938/jkps.77.1253'
Turtle is a human-readable linked data format.
curl -H 'Accept: text/turtle' 'https://scigraph.springernature.com/pub.10.3938/jkps.77.1253'
RDF/XML is a standard XML format for linked data.
curl -H 'Accept: application/rdf+xml' 'https://scigraph.springernature.com/pub.10.3938/jkps.77.1253'
This table displays all metadata directly associated to this object as RDF triples.
221 TRIPLES
22 PREDICATES
126 URIs
114 LITERALS
6 BLANK NODES
Subject | Predicate | Object | |
---|---|---|---|
1 | sg:pub.10.3938/jkps.77.1253 | schema:about | anzsrc-for:02 |
2 | ″ | ″ | anzsrc-for:0299 |
3 | ″ | schema:author | N7d752257e8ca439c8402f3cf895f6560 |
4 | ″ | schema:citation | sg:pub.10.1007/s00247-004-1268-7 |
5 | ″ | ″ | sg:pub.10.1007/s00247-004-1271-z |
6 | ″ | ″ | sg:pub.10.1007/s12194-011-0115-4 |
7 | ″ | ″ | sg:pub.10.1186/s12998-019-0241-3 |
8 | ″ | schema:datePublished | 2020-11-19 |
9 | ″ | schema:datePublishedReg | 2020-11-19 |
10 | ″ | schema:description | Pediatric dosimetry requires extra attention as young children are three times more sensitive to radiation than the average population. Soft tissues of patients absorb low-energy photons without affecting useful diagnostic information. X-ray filters can decrease the exposure dose of radiation by removing low-energy photons from the X-ray beam. Several studies have dealt with the advantages of a conventional filter, copper (Cu), in pediatric digital X-ray radiography. Only a few studies, however, have examined the use of molybdenum (Mo) filters and their impact on the radiation dose and image quality in pediatric digital X-ray imaging. In this study, we investigated the impact of a Mo filter on the image quality and the entrance surface exposure (ESE) in pediatric X-ray imaging and assessed the potential of additional dose reduction compared to a conventional Cu filter. The performance of the Mo filter was investigated and compared with that of Cu filter. Two types of phantoms were used: a customized quantitative phantom (Phantom A) for quantitative comparison and a computational anthropomorphic extended cardiac-torso (XCAT) phantom for qualitative comparison. A clinical radiography system was modeled, and the clinical setting for pediatric chest X-ray imaging was considered. Geant4 simulations using Monte Carlo toolkits were performed to obtain the images for pediatric chest X-ray examinations. Quantitative and qualitative comparisons using the quantitative phantom (Phantom A) and the XCAT phantom, respectively, were performed for both filters. From the customized quantitative phantom study, the ESE for the Mo filter was compared with that for the Cu filter when contrast-to-noise ratio (CNR) was equal. In addition, to validate our Monte Carlo model, we compared simulated and experimentally acquired images. From the results, the ESE for the Cu filter was 22.62 μGy while the ESE for the Mo filter was 18.18 μGy for 5-mm soft tissue. The use of a Mo filter results in a reduction in the dose by 19.60%. From the XCAT phantom study, the image for the Mo filter was superior to that for Cu filter in terms of noise and recognition of blood vessels. The performance characteristics of the Mo filter were evaluated in terms of image quality and radiation dose by comparing those characteristics to the ones for a conventional Cu filter. Our results demonstrated that the use of the Mo filter can significantly reduce the radiation dose. Based on this result, Mo filters are recommended for use in pediatric digital X-ray imaging. |
11 | ″ | schema:genre | article |
12 | ″ | schema:inLanguage | en |
13 | ″ | schema:isAccessibleForFree | false |
14 | ″ | schema:isPartOf | N0a55fefe4fd145e58037aca4d64dd1a4 |
15 | ″ | ″ | N537d1e063155467bbb9ec0e1d63fa114 |
16 | ″ | ″ | sg:journal.1042000 |
17 | ″ | schema:keywords | Carlo model |
18 | ″ | ″ | Cu filter |
19 | ″ | ″ | Geant4 simulations |
20 | ″ | ″ | Mo filter |
21 | ″ | ″ | Monte Carlo model |
22 | ″ | ″ | Monte Carlo toolkit |
23 | ″ | ″ | Simulated |
24 | ″ | ″ | X-ray beam |
25 | ″ | ″ | X-ray examination |
26 | ″ | ″ | X-ray filters |
27 | ″ | ″ | X-ray imaging |
28 | ″ | ″ | X-ray radiography |
29 | ″ | ″ | XCAT phantom |
30 | ″ | ″ | addition |
31 | ″ | ″ | additional dose reduction |
32 | ″ | ″ | advantages |
33 | ″ | ″ | anthropomorphic |
34 | ″ | ″ | attention |
35 | ″ | ″ | average population |
36 | ″ | ″ | beam |
37 | ″ | ″ | blood vessels |
38 | ″ | ″ | cardiac-torso (NCAT) phantom |
39 | ″ | ″ | characteristics |
40 | ″ | ″ | chest X-ray examination |
41 | ″ | ″ | chest X-ray imaging |
42 | ″ | ″ | children |
43 | ″ | ″ | clinical setting |
44 | ″ | ″ | comparison |
45 | ″ | ″ | contrast |
46 | ″ | ″ | conventional filters |
47 | ″ | ″ | copper |
48 | ″ | ″ | diagnostic information |
49 | ″ | ″ | digital X-ray imaging |
50 | ″ | ″ | digital X-ray radiography |
51 | ″ | ″ | dose |
52 | ″ | ″ | dose reduction |
53 | ″ | ″ | dosimetry |
54 | ″ | ″ | entrance surface exposure |
55 | ″ | ″ | evaluation |
56 | ″ | ″ | examination |
57 | ″ | ″ | exposure |
58 | ″ | ″ | exposure dose |
59 | ″ | ″ | extra attention |
60 | ″ | ″ | filter |
61 | ″ | ″ | filter results |
62 | ″ | ″ | image quality |
63 | ″ | ″ | images |
64 | ″ | ″ | imaging |
65 | ″ | ″ | impact |
66 | ″ | ″ | information |
67 | ″ | ″ | low-energy photons |
68 | ″ | ″ | model |
69 | ″ | ″ | molybdenum |
70 | ″ | ″ | molybdenum filter |
71 | ″ | ″ | noise |
72 | ″ | ″ | noise ratio |
73 | ″ | ″ | one |
74 | ″ | ″ | patients |
75 | ″ | ″ | pediatric chest X-ray examinations |
76 | ″ | ″ | performance |
77 | ″ | ″ | performance characteristics |
78 | ″ | ″ | phantom |
79 | ″ | ″ | phantom study |
80 | ″ | ″ | photons |
81 | ″ | ″ | population |
82 | ″ | ″ | potential |
83 | ″ | ″ | qualitative comparison |
84 | ″ | ″ | quality |
85 | ″ | ″ | quantitative comparison |
86 | ″ | ″ | quantitative phantoms |
87 | ″ | ″ | radiation |
88 | ″ | ″ | radiation dose |
89 | ″ | ″ | radiography |
90 | ″ | ″ | radiography system |
91 | ″ | ″ | ratio |
92 | ″ | ″ | recognition |
93 | ″ | ″ | reduction |
94 | ″ | ″ | results |
95 | ″ | ″ | setting |
96 | ″ | ″ | simulations |
97 | ″ | ″ | soft tissue |
98 | ″ | ″ | study |
99 | ″ | ″ | surface exposure |
100 | ″ | ″ | system |
101 | ″ | ″ | terms |
102 | ″ | ″ | terms of noise |
103 | ″ | ″ | time |
104 | ″ | ″ | tissue |
105 | ″ | ″ | toolkit |
106 | ″ | ″ | types |
107 | ″ | ″ | types of phantoms |
108 | ″ | ″ | use |
109 | ″ | ″ | use of molybdenum |
110 | ″ | ″ | useful diagnostic information |
111 | ″ | ″ | vessels |
112 | ″ | ″ | young children |
113 | ″ | ″ | μGy |
114 | ″ | schema:name | Evaluation of the Use of a Molybdenum Filter for Dose Reduction in Pediatric Digital X-ray Imaging |
115 | ″ | schema:pagination | 1253-1259 |
116 | ″ | schema:productId | N05b601bb000e46f2a029ec4d14cea041 |
117 | ″ | ″ | Nf319329d2fcc4a4db63c9cb87c40ad38 |
118 | ″ | schema:sameAs | https://app.dimensions.ai/details/publication/pub.1132774760 |
119 | ″ | ″ | https://doi.org/10.3938/jkps.77.1253 |
120 | ″ | schema:sdDatePublished | 2022-06-01T22:21 |
121 | ″ | schema:sdLicense | https://scigraph.springernature.com/explorer/license/ |
122 | ″ | schema:sdPublisher | N3ee4017dcf9c4a3c8db31731170b7ec6 |
123 | ″ | schema:url | https://doi.org/10.3938/jkps.77.1253 |
124 | ″ | sgo:license | sg:explorer/license/ |
125 | ″ | sgo:sdDataset | articles |
126 | ″ | rdf:type | schema:ScholarlyArticle |
127 | N05b601bb000e46f2a029ec4d14cea041 | schema:name | dimensions_id |
128 | ″ | schema:value | pub.1132774760 |
129 | ″ | rdf:type | schema:PropertyValue |
130 | N0a1a7fe0a31f4675bf28aa1cdedb5a5a | rdf:first | Nc341b511e5574a6ea34704b33f08e71e |
131 | ″ | rdf:rest | Nbf7ff8f2cc1b4fae983cbde681594409 |
132 | N0a55fefe4fd145e58037aca4d64dd1a4 | schema:volumeNumber | 77 |
133 | ″ | rdf:type | schema:PublicationVolume |
134 | N0cf4bd1415714341ba5ec0dfdf526be4 | rdf:first | N620e7275efa74e58b86ebdef13d457d9 |
135 | ″ | rdf:rest | Nfb658cf586714d2db25cc4c1d3ffaff2 |
136 | N2ccecfd90c914d73b43283535e8040fc | schema:affiliation | grid-institutes:grid.419666.a |
137 | ″ | schema:familyName | Park |
138 | ″ | schema:givenName | Su-Jin |
139 | ″ | rdf:type | schema:Person |
140 | N395fb115c2df493cb88f21c0cf042074 | rdf:first | sg:person.012035044352.56 |
141 | ″ | rdf:rest | Nbd68237fa5a04d6aa810bd6ae3547db3 |
142 | N3ee4017dcf9c4a3c8db31731170b7ec6 | schema:name | Springer Nature - SN SciGraph project |
143 | ″ | rdf:type | schema:Organization |
144 | N446f6c38805744338bdde847930783a2 | rdf:first | N462143cc6a204a13a9d2baf51e56ce74 |
145 | ″ | rdf:rest | rdf:nil |
146 | N462143cc6a204a13a9d2baf51e56ce74 | schema:affiliation | grid-institutes:grid.419666.a |
147 | ″ | schema:familyName | Kim |
148 | ″ | schema:givenName | Jung Woo |
149 | ″ | rdf:type | schema:Person |
150 | N537d1e063155467bbb9ec0e1d63fa114 | schema:issueNumber | 12 |
151 | ″ | rdf:type | schema:PublicationIssue |
152 | N620e7275efa74e58b86ebdef13d457d9 | schema:affiliation | grid-institutes:grid.419666.a |
153 | ″ | schema:familyName | Kim |
154 | ″ | schema:givenName | Jong-Pil |
155 | ″ | rdf:type | schema:Person |
156 | N65158a38b10146758f0396398ca480cd | schema:affiliation | grid-institutes:grid.419666.a |
157 | ″ | schema:familyName | Kim |
158 | ″ | schema:givenName | Jung-Min |
159 | ″ | rdf:type | schema:Person |
160 | N7d752257e8ca439c8402f3cf895f6560 | rdf:first | N2ccecfd90c914d73b43283535e8040fc |
161 | ″ | rdf:rest | N395fb115c2df493cb88f21c0cf042074 |
162 | Nbd68237fa5a04d6aa810bd6ae3547db3 | rdf:first | sg:person.010462010223.35 |
163 | ″ | rdf:rest | N0a1a7fe0a31f4675bf28aa1cdedb5a5a |
164 | Nbf7ff8f2cc1b4fae983cbde681594409 | rdf:first | N65158a38b10146758f0396398ca480cd |
165 | ″ | rdf:rest | N0cf4bd1415714341ba5ec0dfdf526be4 |
166 | Nc341b511e5574a6ea34704b33f08e71e | schema:affiliation | grid-institutes:grid.419666.a |
167 | ″ | schema:familyName | Kim |
168 | ″ | schema:givenName | Jung-Ha |
169 | ″ | rdf:type | schema:Person |
170 | Nf319329d2fcc4a4db63c9cb87c40ad38 | schema:name | doi |
171 | ″ | schema:value | 10.3938/jkps.77.1253 |
172 | ″ | rdf:type | schema:PropertyValue |
173 | Nfb658cf586714d2db25cc4c1d3ffaff2 | rdf:first | sg:person.07460435466.55 |
174 | ″ | rdf:rest | N446f6c38805744338bdde847930783a2 |
175 | anzsrc-for:02 | schema:inDefinedTermSet | anzsrc-for: |
176 | ″ | schema:name | Physical Sciences |
177 | ″ | rdf:type | schema:DefinedTerm |
178 | anzsrc-for:0299 | schema:inDefinedTermSet | anzsrc-for: |
179 | ″ | schema:name | Other Physical Sciences |
180 | ″ | rdf:type | schema:DefinedTerm |
181 | sg:journal.1042000 | schema:issn | 0374-4884 |
182 | ″ | ″ | 1976-8524 |
183 | ″ | schema:name | Journal of the Korean Physical Society |
184 | ″ | schema:publisher | Korean Physical Society |
185 | ″ | rdf:type | schema:Periodical |
186 | sg:person.010462010223.35 | schema:affiliation | grid-institutes:grid.419666.a |
187 | ″ | schema:familyName | Han |
188 | ″ | schema:givenName | Jong Chul |
189 | ″ | schema:sameAs | https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.010462010223.35 |
190 | ″ | rdf:type | schema:Person |
191 | sg:person.012035044352.56 | schema:affiliation | grid-institutes:grid.419666.a |
192 | ″ | schema:familyName | Kim |
193 | ″ | schema:givenName | Jaehyuk |
194 | ″ | schema:sameAs | https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.012035044352.56 |
195 | ″ | rdf:type | schema:Person |
196 | sg:person.07460435466.55 | schema:affiliation | grid-institutes:grid.419666.a |
197 | ″ | schema:familyName | Cho |
198 | ″ | schema:givenName | Minkook |
199 | ″ | schema:sameAs | https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.07460435466.55 |
200 | ″ | rdf:type | schema:Person |
201 | sg:pub.10.1007/s00247-004-1268-7 | schema:sameAs | https://app.dimensions.ai/details/publication/pub.1035649403 |
202 | ″ | ″ | https://doi.org/10.1007/s00247-004-1268-7 |
203 | ″ | rdf:type | schema:CreativeWork |
204 | sg:pub.10.1007/s00247-004-1271-z | schema:sameAs | https://app.dimensions.ai/details/publication/pub.1052373401 |
205 | ″ | ″ | https://doi.org/10.1007/s00247-004-1271-z |
206 | ″ | rdf:type | schema:CreativeWork |
207 | sg:pub.10.1007/s12194-011-0115-4 | schema:sameAs | https://app.dimensions.ai/details/publication/pub.1031190353 |
208 | ″ | ″ | https://doi.org/10.1007/s12194-011-0115-4 |
209 | ″ | rdf:type | schema:CreativeWork |
210 | sg:pub.10.1186/s12998-019-0241-3 | schema:sameAs | https://app.dimensions.ai/details/publication/pub.1113843614 |
211 | ″ | ″ | https://doi.org/10.1186/s12998-019-0241-3 |
212 | ″ | rdf:type | schema:CreativeWork |
213 | grid-institutes:grid.419666.a | schema:alternateName | DR Business Team, DR R&D Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 16677, Suwon, Korea |
214 | ″ | ″ | H/W Solution Team, CAE Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 13530, Seongnam, Korea |
215 | ″ | ″ | H/W Solution Team, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 13530, Seongnam, Korea |
216 | ″ | ″ | H/W Solution Team, PCD R&D Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 16677, Suwon, Korea |
217 | ″ | schema:name | DR Business Team, DR R&D Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 16677, Suwon, Korea |
218 | ″ | ″ | H/W Solution Team, CAE Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 13530, Seongnam, Korea |
219 | ″ | ″ | H/W Solution Team, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 13530, Seongnam, Korea |
220 | ″ | ″ | H/W Solution Team, PCD R&D Group, Health and Medical Equipment Business, Samsung Electronics Co., Ltd., 16677, Suwon, Korea |
221 | ″ | rdf:type | schema:Organization |