Cardiovascular cine imaging and flow evaluation using Fast Interrupted Steady-State (FISS) magnetic resonance View Full Text


Ontology type: schema:ScholarlyArticle      Open Access: True


Article Info

DATE

2018-02-19

AUTHORS

Robert R. Edelman, Ali Serhal, Amit Pursnani, Jianing Pang, Ioannis Koktzoglou

ABSTRACT

BACKGROUND: Existing cine imaging techniques rely on balanced steady-state free precession (bSSFP) or spoiled gradient-echo readouts, each of which has limitations. For instance, with bSSFP, artifacts occur from rapid through-plane flow and off-resonance effects. We hypothesized that a prototype cine technique, radial fast interrupted steady-state (FISS), could overcome these limitations. The technique was compared with standard cine bSSFP for cardiac function, coronary artery conspicuity, and aortic valve morphology. Given its advantageous properties, we further hypothesized that the cine FISS technique, in combination with arterial spin labeling (ASL), could provide an alternative to phase contrast for visualizing in-plane flow patterns within the aorta and branch vessels. MAIN BODY: The study was IRB-approved and subjects provided consent. Breath-hold cine FISS and bSSFP were acquired using similar imaging parameters. There was no significant difference in biplane left ventricular ejection fraction or cardiac image quality between the two techniques. Compared with cine bSSFP, cine FISS demonstrated a marked decrease in fat signal which improved conspicuity of the coronary arteries, while suppression of through-plane flow artifact on thin-slice cine FISS images improved visualization of the aortic valve. Banding artifacts in the subcutaneous tissues were reduced. In healthy subjects, dynamic flow patterns were well visualized in the aorta, coronary and renal arteries using cine FISS ASL, even when the slice was substantially thicker than the vessel diameter. CONCLUSION: Cine FISS demonstrates several benefits for cardiovascular imaging compared with cine bSSFP, including better suppression of fat signal and reduced artifacts from through-plane flow and off-resonance effects. The main drawback is a slight (~ 20%) decrease in temporal resolution. In addition, preliminary results suggest that cine FISS ASL provides a potential alternative to phase contrast techniques for in-plane flow quantification, while enabling an efficient, visually-appealing, semi-projective display of blood flow patterns throughout the course of an artery and its branches. More... »

PAGES

12

Identifiers

URI

http://scigraph.springernature.com/pub.10.1186/s12968-018-0433-3

DOI

http://dx.doi.org/10.1186/s12968-018-0433-3

DIMENSIONS

https://app.dimensions.ai/details/publication/pub.1101116870

PUBMED

https://www.ncbi.nlm.nih.gov/pubmed/29458384


Indexing Status Check whether this publication has been indexed by Scopus and Web Of Science using the SN Indexing Status Tool
Incoming Citations Browse incoming citations for this publication using opencitations.net

JSON-LD is the canonical representation for SciGraph data.

TIP: You can open this SciGraph record using an external JSON-LD service: JSON-LD Playground Google SDTT

[
  {
    "@context": "https://springernature.github.io/scigraph/jsonld/sgcontext.json", 
    "about": [
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/11", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "name": "Medical and Health Sciences", 
        "type": "DefinedTerm"
      }, 
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/1102", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "name": "Cardiorespiratory Medicine and Haematology", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Adult", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Aorta", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Blood Flow Velocity", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Breath Holding", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Case-Control Studies", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Coronary Circulation", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Coronary Vessels", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Female", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Heart", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Humans", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Image Interpretation, Computer-Assisted", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Magnetic Resonance Imaging, Cine", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Male", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Middle Aged", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Myocardial Perfusion Imaging", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Predictive Value of Tests", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Regional Blood Flow", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Renal Artery", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Renal Circulation", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Young Adult", 
        "type": "DefinedTerm"
      }
    ], 
    "author": [
      {
        "affiliation": {
          "alternateName": "Evanston, IL USA", 
          "id": "http://www.grid.ac/institutes/None", 
          "name": [
            "Radiology, Northshore University HealthSystem, Evanston, IL USA", 
            "Radiology, Northwestern Memorial Hospital, Chicago, IL USA", 
            "Evanston, IL USA"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Edelman", 
        "givenName": "Robert R.", 
        "id": "sg:person.014627754717.92", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.014627754717.92"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Radiology, Northwestern Memorial Hospital, Chicago, IL USA", 
          "id": "http://www.grid.ac/institutes/grid.416565.5", 
          "name": [
            "Radiology, Northshore University HealthSystem, Evanston, IL USA", 
            "Radiology, Northwestern Memorial Hospital, Chicago, IL USA"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Serhal", 
        "givenName": "Ali", 
        "id": "sg:person.016603525655.62", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.016603525655.62"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Medicine, University of Chicago Pritzker School of Medicine, Chicago, IL USA", 
          "id": "http://www.grid.ac/institutes/grid.170205.1", 
          "name": [
            "Medicine, Northshore University HealthSystem, Evanston, IL USA", 
            "Medicine, University of Chicago Pritzker School of Medicine, Chicago, IL USA"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Pursnani", 
        "givenName": "Amit", 
        "id": "sg:person.0637335436.29", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0637335436.29"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Siemens Medical Solutions USA Inc., Chicago, IL USA", 
          "id": "http://www.grid.ac/institutes/None", 
          "name": [
            "Siemens Medical Solutions USA Inc., Chicago, IL USA"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Pang", 
        "givenName": "Jianing", 
        "id": "sg:person.01067525465.28", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01067525465.28"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Radiology, University of Chicago Pritzker School of Medicine, Chicago, IL USA", 
          "id": "http://www.grid.ac/institutes/grid.170205.1", 
          "name": [
            "Radiology, Northshore University HealthSystem, Evanston, IL USA", 
            "Radiology, University of Chicago Pritzker School of Medicine, Chicago, IL USA"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Koktzoglou", 
        "givenName": "Ioannis", 
        "id": "sg:person.01356351436.29", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01356351436.29"
        ], 
        "type": "Person"
      }
    ], 
    "citation": [
      {
        "id": "sg:pub.10.1186/s12968-015-0172-7", 
        "sameAs": [
          "https://app.dimensions.ai/details/publication/pub.1037010519", 
          "https://doi.org/10.1186/s12968-015-0172-7"
        ], 
        "type": "CreativeWork"
      }, 
      {
        "id": "sg:pub.10.1007/s13244-013-0301-5", 
        "sameAs": [
          "https://app.dimensions.ai/details/publication/pub.1053386812", 
          "https://doi.org/10.1007/s13244-013-0301-5"
        ], 
        "type": "CreativeWork"
      }, 
      {
        "id": "sg:pub.10.1186/s12968-015-0205-2", 
        "sameAs": [
          "https://app.dimensions.ai/details/publication/pub.1015676681", 
          "https://doi.org/10.1186/s12968-015-0205-2"
        ], 
        "type": "CreativeWork"
      }
    ], 
    "datePublished": "2018-02-19", 
    "datePublishedReg": "2018-02-19", 
    "description": "BACKGROUND: Existing cine imaging techniques rely on balanced steady-state free precession (bSSFP) or spoiled gradient-echo readouts, each of which has limitations. For instance, with bSSFP, artifacts occur from rapid through-plane flow and off-resonance effects. We hypothesized that a prototype cine technique, radial fast interrupted steady-state (FISS), could overcome these limitations. The technique was compared with standard cine bSSFP for cardiac function, coronary artery conspicuity, and aortic valve morphology. Given its advantageous properties, we further hypothesized that the cine FISS technique, in combination with arterial spin labeling (ASL), could provide an alternative to phase contrast for visualizing in-plane flow patterns within the aorta and branch vessels.\nMAIN BODY: The study was IRB-approved and subjects provided consent. Breath-hold cine FISS and bSSFP were acquired using similar imaging parameters. There was no significant difference in biplane left ventricular ejection fraction or cardiac image quality between the two techniques. Compared with cine bSSFP, cine FISS demonstrated a marked decrease in fat signal which improved conspicuity of the coronary arteries, while suppression of through-plane flow artifact on thin-slice cine FISS images improved visualization of the aortic valve. Banding artifacts in the subcutaneous tissues were reduced. In healthy subjects, dynamic flow patterns were well visualized in the aorta, coronary and renal arteries using cine FISS ASL, even when the slice was substantially thicker than the vessel diameter.\nCONCLUSION: Cine FISS demonstrates several benefits for cardiovascular imaging compared with cine bSSFP, including better suppression of fat signal and reduced artifacts from through-plane flow and off-resonance effects. The main drawback is a slight (~\u200920%) decrease in temporal resolution. In addition, preliminary results suggest that cine FISS ASL provides a potential alternative to phase contrast techniques for in-plane flow quantification, while enabling an efficient, visually-appealing, semi-projective display of blood flow patterns throughout the course of an artery and its branches.", 
    "genre": "article", 
    "id": "sg:pub.10.1186/s12968-018-0433-3", 
    "inLanguage": "en", 
    "isAccessibleForFree": true, 
    "isFundedItemOf": [
      {
        "id": "sg:grant.4729519", 
        "type": "MonetaryGrant"
      }, 
      {
        "id": "sg:grant.4177425", 
        "type": "MonetaryGrant"
      }, 
      {
        "id": "sg:grant.7171761", 
        "type": "MonetaryGrant"
      }
    ], 
    "isPartOf": [
      {
        "id": "sg:journal.1030439", 
        "issn": [
          "1548-7679", 
          "1879-2855"
        ], 
        "name": "Journal of Cardiovascular Magnetic Resonance", 
        "publisher": "Springer Nature", 
        "type": "Periodical"
      }, 
      {
        "issueNumber": "1", 
        "type": "PublicationIssue"
      }, 
      {
        "type": "PublicationVolume", 
        "volumeNumber": "20"
      }
    ], 
    "keywords": [
      "arterial spin labeling", 
      "cine balanced steady-state free precession", 
      "ventricular ejection fraction", 
      "aortic valve morphology", 
      "blood flow patterns", 
      "ejection fraction", 
      "renal artery", 
      "coronary artery", 
      "cardiac function", 
      "aortic valve", 
      "healthy subjects", 
      "branch vessels", 
      "steady-state magnetic resonance", 
      "subcutaneous tissue", 
      "cardiovascular imaging", 
      "artery", 
      "valve morphology", 
      "balanced steady-state free precession", 
      "vessel diameter", 
      "marked decrease", 
      "standard cine", 
      "significant differences", 
      "similar imaging parameters", 
      "aorta", 
      "cardiac image quality", 
      "cine technique", 
      "imaging parameters", 
      "fat signal", 
      "flow quantification", 
      "steady-state free precession", 
      "imaging techniques", 
      "magnetic resonance", 
      "spin labeling", 
      "subjects", 
      "flow artifacts", 
      "imaging", 
      "conspicuity", 
      "suppression", 
      "slight decrease", 
      "IRB", 
      "contrast technique", 
      "decrease", 
      "consent", 
      "tissue", 
      "free precession", 
      "potential alternative", 
      "vessels", 
      "effect", 
      "preliminary results", 
      "slices", 
      "patterns", 
      "biplane", 
      "valve", 
      "cine", 
      "course", 
      "image quality", 
      "differences", 
      "labeling", 
      "evaluation", 
      "study", 
      "benefits", 
      "alternative", 
      "contrast", 
      "better suppression", 
      "FISS", 
      "gradient echo readout", 
      "dynamic flow patterns", 
      "reduced artifacts", 
      "limitations", 
      "technique", 
      "combination", 
      "function", 
      "addition", 
      "quality", 
      "fraction", 
      "quantification", 
      "diameter", 
      "flow patterns", 
      "visualization", 
      "results", 
      "temporal resolution", 
      "branches", 
      "banding artifacts", 
      "flow", 
      "signals", 
      "artifacts", 
      "resonance", 
      "morphology", 
      "instances", 
      "parameters", 
      "resolution", 
      "readout", 
      "images", 
      "display", 
      "off-resonance effects", 
      "drawbacks", 
      "advantageous properties", 
      "main drawback", 
      "properties", 
      "plane flow", 
      "precession", 
      "cine imaging techniques", 
      "prototype cine technique", 
      "coronary artery conspicuity", 
      "artery conspicuity", 
      "cine FISS technique", 
      "FISS technique", 
      "plane flow patterns", 
      "Breath-hold cine FISS", 
      "cine FISS", 
      "plane flow artifact", 
      "thin-slice cine FISS images", 
      "cine FISS images", 
      "FISS images", 
      "cine FISS ASL", 
      "FISS ASL", 
      "plane flow quantification", 
      "semi-projective display", 
      "Fast Interrupted Steady-State (FISS) magnetic resonance", 
      "Interrupted Steady-State (FISS) magnetic resonance"
    ], 
    "name": "Cardiovascular cine imaging and flow evaluation using Fast Interrupted Steady-State (FISS) magnetic resonance", 
    "pagination": "12", 
    "productId": [
      {
        "name": "dimensions_id", 
        "type": "PropertyValue", 
        "value": [
          "pub.1101116870"
        ]
      }, 
      {
        "name": "doi", 
        "type": "PropertyValue", 
        "value": [
          "10.1186/s12968-018-0433-3"
        ]
      }, 
      {
        "name": "pubmed_id", 
        "type": "PropertyValue", 
        "value": [
          "29458384"
        ]
      }
    ], 
    "sameAs": [
      "https://doi.org/10.1186/s12968-018-0433-3", 
      "https://app.dimensions.ai/details/publication/pub.1101116870"
    ], 
    "sdDataset": "articles", 
    "sdDatePublished": "2021-11-01T18:33", 
    "sdLicense": "https://scigraph.springernature.com/explorer/license/", 
    "sdPublisher": {
      "name": "Springer Nature - SN SciGraph project", 
      "type": "Organization"
    }, 
    "sdSource": "s3://com-springernature-scigraph/baseset/20211101/entities/gbq_results/article/article_785.jsonl", 
    "type": "ScholarlyArticle", 
    "url": "https://doi.org/10.1186/s12968-018-0433-3"
  }
]
 

Download the RDF metadata as:  json-ld nt turtle xml License info

HOW TO GET THIS DATA PROGRAMMATICALLY:

JSON-LD is a popular format for linked data which is fully compatible with JSON.

curl -H 'Accept: application/ld+json' 'https://scigraph.springernature.com/pub.10.1186/s12968-018-0433-3'

N-Triples is a line-based linked data format ideal for batch operations.

curl -H 'Accept: application/n-triples' 'https://scigraph.springernature.com/pub.10.1186/s12968-018-0433-3'

Turtle is a human-readable linked data format.

curl -H 'Accept: text/turtle' 'https://scigraph.springernature.com/pub.10.1186/s12968-018-0433-3'

RDF/XML is a standard XML format for linked data.

curl -H 'Accept: application/rdf+xml' 'https://scigraph.springernature.com/pub.10.1186/s12968-018-0433-3'


 

This table displays all metadata directly associated to this object as RDF triples.

323 TRIPLES      22 PREDICATES      169 URIs      158 LITERALS      27 BLANK NODES

Subject Predicate Object
1 sg:pub.10.1186/s12968-018-0433-3 schema:about N17afd6a211b74b32b5bcc9de66dbb3b7
2 N1b8e265bda52402dbbca79c092b0fdf9
3 N1f6caab09839495c8f0af2a60cb3fd16
4 N23d026d066b4429f88d6c4a661259b34
5 N298923c84bd54315a831aff81465a887
6 N3e38864cd2be4abfbd408671d01af638
7 N479acbd5199c4585b0488dad2c839283
8 N4d2d8346041f49b18636a49d8c7d84a5
9 N64d82725567f4de2959ee3f4906c8cb6
10 N8b884461e1ae4bbdacfefa12329517c4
11 N94b7639c38c043a3bb7c288f41c8f713
12 N9cec5a384ab04bf9a2d43a084b504086
13 N9e4edae0b7af4be5821ede10a7a90a14
14 Na54d5212c8c7447d9b28a326cfc75b0e
15 Nae7519f84e114083b7e02a4350b67576
16 Nc2f509ea35574f3899955001a1769429
17 Nc42d2a0735d84e308316e474422e864b
18 Ne2b1949073884c4898bc05449724fd27
19 Nf8c753f468ae4d7fb72f886633e7fb5b
20 Nfc43225692964541920c38ed2f4fcca4
21 anzsrc-for:11
22 anzsrc-for:1102
23 schema:author Neccff03e1c734e20b558dab947add2b1
24 schema:citation sg:pub.10.1007/s13244-013-0301-5
25 sg:pub.10.1186/s12968-015-0172-7
26 sg:pub.10.1186/s12968-015-0205-2
27 schema:datePublished 2018-02-19
28 schema:datePublishedReg 2018-02-19
29 schema:description BACKGROUND: Existing cine imaging techniques rely on balanced steady-state free precession (bSSFP) or spoiled gradient-echo readouts, each of which has limitations. For instance, with bSSFP, artifacts occur from rapid through-plane flow and off-resonance effects. We hypothesized that a prototype cine technique, radial fast interrupted steady-state (FISS), could overcome these limitations. The technique was compared with standard cine bSSFP for cardiac function, coronary artery conspicuity, and aortic valve morphology. Given its advantageous properties, we further hypothesized that the cine FISS technique, in combination with arterial spin labeling (ASL), could provide an alternative to phase contrast for visualizing in-plane flow patterns within the aorta and branch vessels. MAIN BODY: The study was IRB-approved and subjects provided consent. Breath-hold cine FISS and bSSFP were acquired using similar imaging parameters. There was no significant difference in biplane left ventricular ejection fraction or cardiac image quality between the two techniques. Compared with cine bSSFP, cine FISS demonstrated a marked decrease in fat signal which improved conspicuity of the coronary arteries, while suppression of through-plane flow artifact on thin-slice cine FISS images improved visualization of the aortic valve. Banding artifacts in the subcutaneous tissues were reduced. In healthy subjects, dynamic flow patterns were well visualized in the aorta, coronary and renal arteries using cine FISS ASL, even when the slice was substantially thicker than the vessel diameter. CONCLUSION: Cine FISS demonstrates several benefits for cardiovascular imaging compared with cine bSSFP, including better suppression of fat signal and reduced artifacts from through-plane flow and off-resonance effects. The main drawback is a slight (~ 20%) decrease in temporal resolution. In addition, preliminary results suggest that cine FISS ASL provides a potential alternative to phase contrast techniques for in-plane flow quantification, while enabling an efficient, visually-appealing, semi-projective display of blood flow patterns throughout the course of an artery and its branches.
30 schema:genre article
31 schema:inLanguage en
32 schema:isAccessibleForFree true
33 schema:isPartOf N24c96d70f27144a1b0de69945132209c
34 N8153730a61f74fe9866c8e93e351b43f
35 sg:journal.1030439
36 schema:keywords Breath-hold cine FISS
37 FISS
38 FISS ASL
39 FISS images
40 FISS technique
41 Fast Interrupted Steady-State (FISS) magnetic resonance
42 IRB
43 Interrupted Steady-State (FISS) magnetic resonance
44 addition
45 advantageous properties
46 alternative
47 aorta
48 aortic valve
49 aortic valve morphology
50 arterial spin labeling
51 artery
52 artery conspicuity
53 artifacts
54 balanced steady-state free precession
55 banding artifacts
56 benefits
57 better suppression
58 biplane
59 blood flow patterns
60 branch vessels
61 branches
62 cardiac function
63 cardiac image quality
64 cardiovascular imaging
65 cine
66 cine FISS
67 cine FISS ASL
68 cine FISS images
69 cine FISS technique
70 cine balanced steady-state free precession
71 cine imaging techniques
72 cine technique
73 combination
74 consent
75 conspicuity
76 contrast
77 contrast technique
78 coronary artery
79 coronary artery conspicuity
80 course
81 decrease
82 diameter
83 differences
84 display
85 drawbacks
86 dynamic flow patterns
87 effect
88 ejection fraction
89 evaluation
90 fat signal
91 flow
92 flow artifacts
93 flow patterns
94 flow quantification
95 fraction
96 free precession
97 function
98 gradient echo readout
99 healthy subjects
100 image quality
101 images
102 imaging
103 imaging parameters
104 imaging techniques
105 instances
106 labeling
107 limitations
108 magnetic resonance
109 main drawback
110 marked decrease
111 morphology
112 off-resonance effects
113 parameters
114 patterns
115 plane flow
116 plane flow artifact
117 plane flow patterns
118 plane flow quantification
119 potential alternative
120 precession
121 preliminary results
122 properties
123 prototype cine technique
124 quality
125 quantification
126 readout
127 reduced artifacts
128 renal artery
129 resolution
130 resonance
131 results
132 semi-projective display
133 signals
134 significant differences
135 similar imaging parameters
136 slices
137 slight decrease
138 spin labeling
139 standard cine
140 steady-state free precession
141 steady-state magnetic resonance
142 study
143 subcutaneous tissue
144 subjects
145 suppression
146 technique
147 temporal resolution
148 thin-slice cine FISS images
149 tissue
150 valve
151 valve morphology
152 ventricular ejection fraction
153 vessel diameter
154 vessels
155 visualization
156 schema:name Cardiovascular cine imaging and flow evaluation using Fast Interrupted Steady-State (FISS) magnetic resonance
157 schema:pagination 12
158 schema:productId N08ca8e0d2fdc498198cf9bd88cfd119c
159 N655b9e5cd92f47c59903e2613da846bd
160 Nccab3cf7eed343d688e06e57394725cd
161 schema:sameAs https://app.dimensions.ai/details/publication/pub.1101116870
162 https://doi.org/10.1186/s12968-018-0433-3
163 schema:sdDatePublished 2021-11-01T18:33
164 schema:sdLicense https://scigraph.springernature.com/explorer/license/
165 schema:sdPublisher N8ec57aff46a047a58b7e92b8a1938214
166 schema:url https://doi.org/10.1186/s12968-018-0433-3
167 sgo:license sg:explorer/license/
168 sgo:sdDataset articles
169 rdf:type schema:ScholarlyArticle
170 N08ca8e0d2fdc498198cf9bd88cfd119c schema:name pubmed_id
171 schema:value 29458384
172 rdf:type schema:PropertyValue
173 N17afd6a211b74b32b5bcc9de66dbb3b7 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
174 schema:name Male
175 rdf:type schema:DefinedTerm
176 N1b8e265bda52402dbbca79c092b0fdf9 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
177 schema:name Case-Control Studies
178 rdf:type schema:DefinedTerm
179 N1f6caab09839495c8f0af2a60cb3fd16 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
180 schema:name Blood Flow Velocity
181 rdf:type schema:DefinedTerm
182 N23d026d066b4429f88d6c4a661259b34 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
183 schema:name Myocardial Perfusion Imaging
184 rdf:type schema:DefinedTerm
185 N24c96d70f27144a1b0de69945132209c schema:volumeNumber 20
186 rdf:type schema:PublicationVolume
187 N298923c84bd54315a831aff81465a887 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
188 schema:name Predictive Value of Tests
189 rdf:type schema:DefinedTerm
190 N3e38864cd2be4abfbd408671d01af638 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
191 schema:name Adult
192 rdf:type schema:DefinedTerm
193 N479acbd5199c4585b0488dad2c839283 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
194 schema:name Middle Aged
195 rdf:type schema:DefinedTerm
196 N4d2d8346041f49b18636a49d8c7d84a5 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
197 schema:name Magnetic Resonance Imaging, Cine
198 rdf:type schema:DefinedTerm
199 N59abe4840ca340aba7ebdc6e25f4e204 rdf:first sg:person.016603525655.62
200 rdf:rest Nf5664a1637424f65b30bf6643f6a2a05
201 N64d82725567f4de2959ee3f4906c8cb6 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
202 schema:name Image Interpretation, Computer-Assisted
203 rdf:type schema:DefinedTerm
204 N655b9e5cd92f47c59903e2613da846bd schema:name doi
205 schema:value 10.1186/s12968-018-0433-3
206 rdf:type schema:PropertyValue
207 N697cf4aadd5a46ecbf70cb79dfab4d17 rdf:first sg:person.01356351436.29
208 rdf:rest rdf:nil
209 N8153730a61f74fe9866c8e93e351b43f schema:issueNumber 1
210 rdf:type schema:PublicationIssue
211 N8b884461e1ae4bbdacfefa12329517c4 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
212 schema:name Humans
213 rdf:type schema:DefinedTerm
214 N8ec57aff46a047a58b7e92b8a1938214 schema:name Springer Nature - SN SciGraph project
215 rdf:type schema:Organization
216 N94b7639c38c043a3bb7c288f41c8f713 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
217 schema:name Female
218 rdf:type schema:DefinedTerm
219 N9cec5a384ab04bf9a2d43a084b504086 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
220 schema:name Aorta
221 rdf:type schema:DefinedTerm
222 N9e4edae0b7af4be5821ede10a7a90a14 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
223 schema:name Young Adult
224 rdf:type schema:DefinedTerm
225 Na54d5212c8c7447d9b28a326cfc75b0e schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
226 schema:name Breath Holding
227 rdf:type schema:DefinedTerm
228 Nae7519f84e114083b7e02a4350b67576 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
229 schema:name Renal Artery
230 rdf:type schema:DefinedTerm
231 Nc2f509ea35574f3899955001a1769429 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
232 schema:name Heart
233 rdf:type schema:DefinedTerm
234 Nc42d2a0735d84e308316e474422e864b schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
235 schema:name Renal Circulation
236 rdf:type schema:DefinedTerm
237 Nccab3cf7eed343d688e06e57394725cd schema:name dimensions_id
238 schema:value pub.1101116870
239 rdf:type schema:PropertyValue
240 Ne2b1949073884c4898bc05449724fd27 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
241 schema:name Regional Blood Flow
242 rdf:type schema:DefinedTerm
243 Ne767cb8ed3da4700b12444a2ee58858d rdf:first sg:person.01067525465.28
244 rdf:rest N697cf4aadd5a46ecbf70cb79dfab4d17
245 Neccff03e1c734e20b558dab947add2b1 rdf:first sg:person.014627754717.92
246 rdf:rest N59abe4840ca340aba7ebdc6e25f4e204
247 Nf5664a1637424f65b30bf6643f6a2a05 rdf:first sg:person.0637335436.29
248 rdf:rest Ne767cb8ed3da4700b12444a2ee58858d
249 Nf8c753f468ae4d7fb72f886633e7fb5b schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
250 schema:name Coronary Circulation
251 rdf:type schema:DefinedTerm
252 Nfc43225692964541920c38ed2f4fcca4 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
253 schema:name Coronary Vessels
254 rdf:type schema:DefinedTerm
255 anzsrc-for:11 schema:inDefinedTermSet anzsrc-for:
256 schema:name Medical and Health Sciences
257 rdf:type schema:DefinedTerm
258 anzsrc-for:1102 schema:inDefinedTermSet anzsrc-for:
259 schema:name Cardiorespiratory Medicine and Haematology
260 rdf:type schema:DefinedTerm
261 sg:grant.4177425 http://pending.schema.org/fundedItem sg:pub.10.1186/s12968-018-0433-3
262 rdf:type schema:MonetaryGrant
263 sg:grant.4729519 http://pending.schema.org/fundedItem sg:pub.10.1186/s12968-018-0433-3
264 rdf:type schema:MonetaryGrant
265 sg:grant.7171761 http://pending.schema.org/fundedItem sg:pub.10.1186/s12968-018-0433-3
266 rdf:type schema:MonetaryGrant
267 sg:journal.1030439 schema:issn 1548-7679
268 1879-2855
269 schema:name Journal of Cardiovascular Magnetic Resonance
270 schema:publisher Springer Nature
271 rdf:type schema:Periodical
272 sg:person.01067525465.28 schema:affiliation grid-institutes:None
273 schema:familyName Pang
274 schema:givenName Jianing
275 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01067525465.28
276 rdf:type schema:Person
277 sg:person.01356351436.29 schema:affiliation grid-institutes:grid.170205.1
278 schema:familyName Koktzoglou
279 schema:givenName Ioannis
280 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01356351436.29
281 rdf:type schema:Person
282 sg:person.014627754717.92 schema:affiliation grid-institutes:None
283 schema:familyName Edelman
284 schema:givenName Robert R.
285 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.014627754717.92
286 rdf:type schema:Person
287 sg:person.016603525655.62 schema:affiliation grid-institutes:grid.416565.5
288 schema:familyName Serhal
289 schema:givenName Ali
290 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.016603525655.62
291 rdf:type schema:Person
292 sg:person.0637335436.29 schema:affiliation grid-institutes:grid.170205.1
293 schema:familyName Pursnani
294 schema:givenName Amit
295 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0637335436.29
296 rdf:type schema:Person
297 sg:pub.10.1007/s13244-013-0301-5 schema:sameAs https://app.dimensions.ai/details/publication/pub.1053386812
298 https://doi.org/10.1007/s13244-013-0301-5
299 rdf:type schema:CreativeWork
300 sg:pub.10.1186/s12968-015-0172-7 schema:sameAs https://app.dimensions.ai/details/publication/pub.1037010519
301 https://doi.org/10.1186/s12968-015-0172-7
302 rdf:type schema:CreativeWork
303 sg:pub.10.1186/s12968-015-0205-2 schema:sameAs https://app.dimensions.ai/details/publication/pub.1015676681
304 https://doi.org/10.1186/s12968-015-0205-2
305 rdf:type schema:CreativeWork
306 grid-institutes:None schema:alternateName Evanston, IL USA
307 Siemens Medical Solutions USA Inc., Chicago, IL USA
308 schema:name Evanston, IL USA
309 Radiology, Northshore University HealthSystem, Evanston, IL USA
310 Radiology, Northwestern Memorial Hospital, Chicago, IL USA
311 Siemens Medical Solutions USA Inc., Chicago, IL USA
312 rdf:type schema:Organization
313 grid-institutes:grid.170205.1 schema:alternateName Medicine, University of Chicago Pritzker School of Medicine, Chicago, IL USA
314 Radiology, University of Chicago Pritzker School of Medicine, Chicago, IL USA
315 schema:name Medicine, Northshore University HealthSystem, Evanston, IL USA
316 Medicine, University of Chicago Pritzker School of Medicine, Chicago, IL USA
317 Radiology, Northshore University HealthSystem, Evanston, IL USA
318 Radiology, University of Chicago Pritzker School of Medicine, Chicago, IL USA
319 rdf:type schema:Organization
320 grid-institutes:grid.416565.5 schema:alternateName Radiology, Northwestern Memorial Hospital, Chicago, IL USA
321 schema:name Radiology, Northshore University HealthSystem, Evanston, IL USA
322 Radiology, Northwestern Memorial Hospital, Chicago, IL USA
323 rdf:type schema:Organization
 




Preview window. Press ESC to close (or click here)


...