Ontology type: schema:ScholarlyArticle Open Access: True
2019-12
AUTHORSMelissa M Meyer, Stefan Haneder, Simon Konstandin, Johannes Budjan, John N Morelli, Lothar R Schad, Hans U Kerl, Stefan O Schoenberg, Christoph Kabbasch
ABSTRACTBACKGROUND: Initial reports of 23Na magnetic resonance imaging (MRI) date back to the 1970s. However, methodological challenges of the technique hampered its widespread adoption for many years. Recent technical developments have overcome some of these limitations and have led to more optimal conditions for 23Na-MR imaging. In order to serve as a reliable tool for the assessment of clinical stroke or brain tumor patients, we investigated the repeatability and reproducibility of cerebral sodium (23Na) imaging in healthy subjects. METHODS: In this prospective, IRB approved study 12 consecutive healthy volunteers (8 female, age 31 ± 8.3) underwent three cerebral 23Na-MRI examinations at 3.0 T (TimTrio, Siemens Healthineers) distributed between two separate visits with an 8 day interval. For each scan a T1w MP-RAGE sequence for anatomical referencing and a 3D-density-adapted, radial GRE-sequence for 23Na-imaging were acquired using a dual-tuned (23Na/1H) head-coil. On 1 day, these scans were repeated consecutively; on the other day, the scans were performed once. 23Na-sequences were reconstructed according to the MP-RAGE sequence, allowing direct cross-referencing of ROIs. Circular ROIs were placed in predetermined anatomic regions: gray and white matter (GM, WM), head of the caudate nucleus (HCN), pons, and cerebellum. External 23Na-reference phantoms were used to calculate the tissue sodium content. RESULTS: Excellent correlation was found between repeated measurements on the same day (r2 = 0.94), as well as on a different day (r2 = 0.86). No significant differences were found based on laterality other than in the HCN (63.1 vs. 58.7 mmol/kg WW on the right (p = 0.01)). Pronounced inter-individual differences were identified in all anatomic regions. Moderate to good correlation (0.310 to 0.701) was found between the readers. CONCLUSION: Our study has shown that intra-individual 23Na-concentrations in healthy subjects do not significantly differ after repeated scans on the same day and a pre-set time interval. This confirms the repeatability and reproducibility of cerebral 23Na-imaging. However, with manual ROI placement in predetermined anatomic landmarks, fluctuations in 23Na-concentrations can be observed. More... »
PAGES26
http://scigraph.springernature.com/pub.10.1186/s12880-019-0324-6
DOIhttp://dx.doi.org/10.1186/s12880-019-0324-6
DIMENSIONShttps://app.dimensions.ai/details/publication/pub.1113181755
PUBMEDhttps://www.ncbi.nlm.nih.gov/pubmed/30943911
JSON-LD is the canonical representation for SciGraph data.
TIP: You can open this SciGraph record using an external JSON-LD service: JSON-LD Playground Google SDTT
[
{
"@context": "https://springernature.github.io/scigraph/jsonld/sgcontext.json",
"about": [
{
"id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/1103",
"inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/",
"name": "Clinical Sciences",
"type": "DefinedTerm"
},
{
"id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/11",
"inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/",
"name": "Medical and Health Sciences",
"type": "DefinedTerm"
}
],
"author": [
{
"affiliation": {
"alternateName": "Heidelberg University",
"id": "https://www.grid.ac/institutes/grid.7700.0",
"name": [
"Institute of Clinical Radiology and Nuclear Medicine, Medical Faculty Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany. melissa.ong@gmx.de."
],
"type": "Organization"
},
"familyName": "Meyer",
"givenName": "Melissa M",
"type": "Person"
},
{
"affiliation": {
"alternateName": "Heidelberg University",
"id": "https://www.grid.ac/institutes/grid.7700.0",
"name": [
"Institute of Clinical Radiology and Nuclear Medicine, Medical Faculty Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.",
"Institute of Diagnostic and Interventional Radiology, University Hospital Cologne, University of Cologne, Cologne, Germany."
],
"type": "Organization"
},
"familyName": "Haneder",
"givenName": "Stefan",
"type": "Person"
},
{
"affiliation": {
"alternateName": "Fraunhofer MEVIS",
"id": "https://www.grid.ac/institutes/grid.428590.2",
"name": [
"MR Physics, Fraunhofer MEVIS, Bremen, Germany."
],
"type": "Organization"
},
"familyName": "Konstandin",
"givenName": "Simon",
"type": "Person"
},
{
"affiliation": {
"alternateName": "Heidelberg University",
"id": "https://www.grid.ac/institutes/grid.7700.0",
"name": [
"Institute of Clinical Radiology and Nuclear Medicine, Medical Faculty Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany."
],
"type": "Organization"
},
"familyName": "Budjan",
"givenName": "Johannes",
"type": "Person"
},
{
"affiliation": {
"name": [
"St. John's Medical Center, 1923 South Utica Ave, Tulsa, OK, 74104, USA."
],
"type": "Organization"
},
"familyName": "Morelli",
"givenName": "John N",
"type": "Person"
},
{
"affiliation": {
"alternateName": "Heidelberg University",
"id": "https://www.grid.ac/institutes/grid.7700.0",
"name": [
"Department of Computer Assisted Clinical Medicine, Heidelberg University, Mannheim, Germany."
],
"type": "Organization"
},
"familyName": "Schad",
"givenName": "Lothar R",
"type": "Person"
},
{
"affiliation": {
"alternateName": "University Medical Centre Mannheim",
"id": "https://www.grid.ac/institutes/grid.411778.c",
"name": [
"Department of Neuroradiology, University Medical Center Mannheim, Heidelberg University, Mannheim, Germany."
],
"type": "Organization"
},
"familyName": "Kerl",
"givenName": "Hans U",
"type": "Person"
},
{
"affiliation": {
"alternateName": "Heidelberg University",
"id": "https://www.grid.ac/institutes/grid.7700.0",
"name": [
"Institute of Clinical Radiology and Nuclear Medicine, Medical Faculty Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany."
],
"type": "Organization"
},
"familyName": "Schoenberg",
"givenName": "Stefan O",
"type": "Person"
},
{
"affiliation": {
"name": [
"Institute of Diagnostic and Interventional Radiology, University Hospital Cologne, University of Cologne, Cologne, Germany."
],
"type": "Organization"
},
"familyName": "Kabbasch",
"givenName": "Christoph",
"type": "Person"
}
],
"citation": [
{
"id": "https://doi.org/10.1111/j.1749-6632.1973.tb30799.x",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1001988745"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1002/mrm.22157",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1002972648"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1002/mrm.22157",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1002972648"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1148/radiol.11102263",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1004572101"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1002/mrm.21031",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1005368863"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/s10334-004-0038-8",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1006657500",
"https://doi.org/10.1007/s10334-004-0038-8"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1016/j.pnmrs.2014.02.001",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1007657157"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1148/radiology.213.1.r99se15156",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1009759087"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1148/radiol.12112680",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1011332729"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/bf02668153",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1021463177",
"https://doi.org/10.1007/bf02668153"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/bf02668153",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1021463177",
"https://doi.org/10.1007/bf02668153"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1016/s1076-6332(03)80023-5",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1022725147"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1016/j.nic.2005.08.003",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1023748118"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/s10334-013-0394-3",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1029300963",
"https://doi.org/10.1007/s10334-013-0394-3"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1186/1743-8454-7-3",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1034619978",
"https://doi.org/10.1186/1743-8454-7-3"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1148/radiology.216.2.r00jl46559",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1035253736"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1148/radiol.2242011039",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1038741443"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1148/radiol.2272020483",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1039401214"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/s00330-012-2508-0",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1043574463",
"https://doi.org/10.1007/s00330-012-2508-0"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/s00330-012-2508-0",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1043574463",
"https://doi.org/10.1007/s00330-012-2508-0"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1016/j.mri.2012.05.011",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1049084548"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1097/rli.0b013e31821ae918",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1049977963"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1097/rli.0b013e31821ae918",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1049977963"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1002/jmri.24168",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1050315940"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1016/j.nic.2009.09.001",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1052317643"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1002/jmri.20237",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1052843447"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1063/1.1674167",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1057750626"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1148/radiology.163.1.3029803",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1079514936"
],
"type": "CreativeWork"
},
{
"id": "https://app.dimensions.ai/details/publication/pub.1081729873",
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1093/oxfordjournals.bmb.a071964",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1081934595"
],
"type": "CreativeWork"
}
],
"datePublished": "2019-12",
"datePublishedReg": "2019-12-01",
"description": "BACKGROUND: Initial reports of 23Na magnetic resonance imaging (MRI) date back to the 1970s. However, methodological challenges of the technique hampered its widespread adoption for many years. Recent technical developments have overcome some of these limitations and have led to more optimal conditions for 23Na-MR imaging. In order to serve as a reliable tool for the assessment of clinical stroke or brain tumor patients, we investigated the repeatability and reproducibility of cerebral sodium (23Na) imaging in healthy subjects.\nMETHODS: In this prospective, IRB approved study 12 consecutive healthy volunteers (8 female, age 31\u2009\u00b1\u20098.3) underwent three cerebral 23Na-MRI examinations at 3.0\u2009T (TimTrio, Siemens Healthineers) distributed between two separate visits with an 8\u2009day interval. For each scan a T1w MP-RAGE sequence for anatomical referencing and a 3D-density-adapted, radial GRE-sequence for 23Na-imaging were acquired using a dual-tuned (23Na/1H) head-coil. On 1\u2009day, these scans were repeated consecutively; on the other day, the scans were performed once. 23Na-sequences were reconstructed according to the MP-RAGE sequence, allowing direct cross-referencing of ROIs. Circular ROIs were placed in predetermined anatomic regions: gray and white matter (GM, WM), head of the caudate nucleus (HCN), pons, and cerebellum. External 23Na-reference phantoms were used to calculate the tissue sodium content.\nRESULTS: Excellent correlation was found between repeated measurements on the same day (r2\u00a0=\u20090.94), as well as on a different day (r2\u00a0=\u20090.86). No significant differences were found based on laterality other than in the HCN (63.1 vs. 58.7\u2009mmol/kg WW on the right (p\u00a0=\u20090.01)). Pronounced inter-individual differences were identified in all anatomic regions. Moderate to good correlation (0.310 to 0.701) was found between the readers.\nCONCLUSION: Our study has shown that intra-individual 23Na-concentrations in healthy subjects do not significantly differ after repeated scans on the same day and a pre-set time interval. This confirms the repeatability and reproducibility of cerebral 23Na-imaging. However, with manual ROI placement in predetermined anatomic landmarks, fluctuations in 23Na-concentrations can be observed.",
"genre": "research_article",
"id": "sg:pub.10.1186/s12880-019-0324-6",
"inLanguage": [
"en"
],
"isAccessibleForFree": true,
"isPartOf": [
{
"id": "sg:journal.1024948",
"issn": [
"1471-2342"
],
"name": "BMC Medical Imaging",
"type": "Periodical"
},
{
"issueNumber": "1",
"type": "PublicationIssue"
},
{
"type": "PublicationVolume",
"volumeNumber": "19"
}
],
"name": "Repeatability and reproducibility of cerebral 23Na imaging in healthy subjects.",
"pagination": "26",
"productId": [
{
"name": "doi",
"type": "PropertyValue",
"value": [
"10.1186/s12880-019-0324-6"
]
},
{
"name": "dimensions_id",
"type": "PropertyValue",
"value": [
"pub.1113181755"
]
},
{
"name": "nlm_unique_id",
"type": "PropertyValue",
"value": [
"100968553"
]
},
{
"name": "pubmed_id",
"type": "PropertyValue",
"value": [
"30943911"
]
}
],
"sameAs": [
"https://doi.org/10.1186/s12880-019-0324-6",
"https://app.dimensions.ai/details/publication/pub.1113181755"
],
"sdDataset": "articles",
"sdDatePublished": "2019-04-16T06:22",
"sdLicense": "https://scigraph.springernature.com/explorer/license/",
"sdPublisher": {
"name": "Springer Nature - SN SciGraph project",
"type": "Organization"
},
"sdSource": "s3://com-uberresearch-data-dimensions-target-20181106-alternative/cleanup/v134/2549eaecd7973599484d7c17b260dba0a4ecb94b/merge/v9/a6c9fde33151104705d4d7ff012ea9563521a3ce/jats-lookup/v90/0000000377_0000000377/records_106816_00000002.jsonl",
"type": "ScholarlyArticle",
"url": "https://bmcmedimaging.biomedcentral.com/articles/10.1186/s12880-019-0324-6"
}
]
Download the RDF metadata as: json-ld nt turtle xml License info
JSON-LD is a popular format for linked data which is fully compatible with JSON.
curl -H 'Accept: application/ld+json' 'https://scigraph.springernature.com/pub.10.1186/s12880-019-0324-6'
N-Triples is a line-based linked data format ideal for batch operations.
curl -H 'Accept: application/n-triples' 'https://scigraph.springernature.com/pub.10.1186/s12880-019-0324-6'
Turtle is a human-readable linked data format.
curl -H 'Accept: text/turtle' 'https://scigraph.springernature.com/pub.10.1186/s12880-019-0324-6'
RDF/XML is a standard XML format for linked data.
curl -H 'Accept: application/rdf+xml' 'https://scigraph.springernature.com/pub.10.1186/s12880-019-0324-6'
This table displays all metadata directly associated to this object as RDF triples.
206 TRIPLES
21 PREDICATES
54 URIs
20 LITERALS
8 BLANK NODES