The lateral displacement of Reinforced Concrete (RC) frame building during an earthquake has an important impact on the structural stability and integrity. However, seismic analysis and design of RC building needs more concern due to its complex behavior as the performance of the structure links to the features of the system having many influencing parameters and other inherent uncertainties. The reliability approach takes into account the factors and uncertainty in design influencing the performance or response of the structure in which the safety level or the probability of failure could be ascertained. This present study, aims to assess the reliability of seismic performance of a four storey residential RC building seismically located in Zone-V as per the code provisions given in the Indian Standards IS: 1893-2002. The reliability assessment performed by deriving an explicit expression for maximum roof-lateral displacement as a failure function by regression method. A total of 319, four storey RC buildings were analyzed by linear static method using SAP2000. However, the change in the lateral-roof displacement with the variation of the parameters (column dimension, beam dimension, grade of concrete, floor height and total weight of the structure) was observed. A generalized relation established by regression method which could be used to estimate the expected lateral displacement owing to those selected parameters. A comparison made between the displacements obtained from analysis with that of the equation so formed. However, it shows that the proposed relation could be used directly to determine the expected maximum lateral displacement. The data obtained from the statistical computations was then used to obtain the probability of failure and the reliability. More... »

PAGES

245-256

Identifiers

URI

http://scigraph.springernature.com/pub.10.1007/s40030-017-0216-0

DOI

http://dx.doi.org/10.1007/s40030-017-0216-0

DIMENSIONS

https://app.dimensions.ai/details/publication/pub.1090898721


Indexing Status Check whether this publication has been indexed by Scopus and Web Of Science using the SN Indexing Status Tool
Incoming Citations Browse incoming citations for this publication using opencitations.net

JSON-LD is the canonical representation for SciGraph data.

TIP: You can open this SciGraph record using an external JSON-LD service: JSON-LD Playground Google SDTT

[
  {
    "@context": "https://springernature.github.io/scigraph/jsonld/sgcontext.json", 
    "about": [
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/09", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "name": "Engineering", 
        "type": "DefinedTerm"
      }, 
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/0905", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "name": "Civil Engineering", 
        "type": "DefinedTerm"
      }
    ], 
    "author": [
      {
        "affiliation": {
          "alternateName": "Department of Civil Engineering, National Institute of Technology Silchar, Silchar, Assam, India", 
          "id": "http://www.grid.ac/institutes/grid.444720.1", 
          "name": [
            "Department of Civil Engineering, National Institute of Technology Silchar, Silchar, Assam, India"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Sil", 
        "givenName": "Arjun", 
        "id": "sg:person.012767414161.53", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.012767414161.53"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Department of Civil Engineering, National Institute of Technology Silchar, Silchar, Assam, India", 
          "id": "http://www.grid.ac/institutes/grid.444720.1", 
          "name": [
            "Department of Civil Engineering, National Institute of Technology Silchar, Silchar, Assam, India"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Longmailai", 
        "givenName": "Thaihamdau", 
        "type": "Person"
      }
    ], 
    "datePublished": "2017-07-26", 
    "datePublishedReg": "2017-07-26", 
    "description": "The lateral displacement of Reinforced Concrete (RC) frame building during an earthquake has an important impact on the structural stability and integrity. However, seismic analysis and design of RC building needs more concern due to its complex behavior as the performance of the structure links to the features of the system having many influencing parameters and other inherent uncertainties. The reliability approach takes into account the factors and uncertainty in design influencing the performance or response of the structure in which the safety level or the probability of failure could be ascertained. This present study, aims to assess the reliability of seismic performance of a four storey residential RC building seismically located in Zone-V as per the code provisions given in the Indian Standards IS: 1893-2002. The reliability assessment performed by deriving an explicit expression for maximum roof-lateral displacement as a failure function by regression method. A total of 319, four storey RC buildings were analyzed by linear static method using SAP2000. However, the change in the lateral-roof displacement with the variation of the parameters (column dimension, beam dimension, grade of concrete, floor height and total weight of the structure) was observed. A generalized relation established by regression method which could be used to estimate the expected lateral displacement owing to those selected parameters. A comparison made between the displacements obtained from analysis with that of the equation so formed. However, it shows that the proposed relation could be used directly to determine the expected maximum lateral displacement. The data obtained from the statistical computations was then used to obtain the probability of failure and the reliability.", 
    "genre": "article", 
    "id": "sg:pub.10.1007/s40030-017-0216-0", 
    "inLanguage": "en", 
    "isAccessibleForFree": false, 
    "isPartOf": [
      {
        "id": "sg:journal.1135971", 
        "issn": [
          "2250-2149", 
          "2250-2157"
        ], 
        "name": "Journal of The Institution of Engineers (India): Series A", 
        "publisher": "Springer Nature", 
        "type": "Periodical"
      }, 
      {
        "issueNumber": "3", 
        "type": "PublicationIssue"
      }, 
      {
        "type": "PublicationVolume", 
        "volumeNumber": "98"
      }
    ], 
    "keywords": [
      "RC buildings", 
      "Reinforced Concrete", 
      "probability of failure", 
      "linear static method", 
      "maximum lateral displacement", 
      "story RC building", 
      "lateral displacement", 
      "reliability assessment", 
      "residential RC buildings", 
      "seismic performance", 
      "displacement owing", 
      "seismic loading", 
      "seismic analysis", 
      "code provisions", 
      "residential buildings", 
      "reliability approach", 
      "safety level", 
      "structural stability", 
      "failure function", 
      "Indian Standards", 
      "displacement", 
      "buildings", 
      "static method", 
      "concrete", 
      "SAP2000", 
      "performance", 
      "inherent uncertainty", 
      "loading", 
      "design", 
      "parameters", 
      "generalized relation", 
      "reliability", 
      "complex behavior", 
      "structure", 
      "method", 
      "uncertainty", 
      "regression method", 
      "explicit expressions", 
      "earthquakes", 
      "stability", 
      "equations", 
      "important impact", 
      "zone", 
      "behavior", 
      "owing", 
      "failure", 
      "system", 
      "analysis", 
      "more concern", 
      "integrity", 
      "account", 
      "computation", 
      "variation", 
      "comparison", 
      "approach", 
      "assessment", 
      "features", 
      "impact", 
      "standards", 
      "factors", 
      "present study", 
      "relation", 
      "data", 
      "statistical computations", 
      "changes", 
      "study", 
      "function", 
      "probability", 
      "concern", 
      "response", 
      "levels", 
      "multiple factors", 
      "provision", 
      "expression", 
      "total", 
      "storey residential RC building", 
      "maximum roof-lateral displacement", 
      "roof-lateral displacement", 
      "lateral-roof displacement", 
      "lateral displacement owing", 
      "expected maximum lateral displacement", 
      "Drift Reliability Assessment", 
      "Four Storey Frame Residential Building", 
      "Storey Frame Residential Building", 
      "Frame Residential Building"
    ], 
    "name": "Drift Reliability Assessment of a Four Storey Frame Residential Building Under Seismic Loading Considering Multiple Factors", 
    "pagination": "245-256", 
    "productId": [
      {
        "name": "dimensions_id", 
        "type": "PropertyValue", 
        "value": [
          "pub.1090898721"
        ]
      }, 
      {
        "name": "doi", 
        "type": "PropertyValue", 
        "value": [
          "10.1007/s40030-017-0216-0"
        ]
      }
    ], 
    "sameAs": [
      "https://doi.org/10.1007/s40030-017-0216-0", 
      "https://app.dimensions.ai/details/publication/pub.1090898721"
    ], 
    "sdDataset": "articles", 
    "sdDatePublished": "2021-11-01T18:31", 
    "sdLicense": "https://scigraph.springernature.com/explorer/license/", 
    "sdPublisher": {
      "name": "Springer Nature - SN SciGraph project", 
      "type": "Organization"
    }, 
    "sdSource": "s3://com-springernature-scigraph/baseset/20211101/entities/gbq_results/article/article_740.jsonl", 
    "type": "ScholarlyArticle", 
    "url": "https://doi.org/10.1007/s40030-017-0216-0"
  }
]
 

Download the RDF metadata as:  json-ld nt turtle xml License info

HOW TO GET THIS DATA PROGRAMMATICALLY:

JSON-LD is a popular format for linked data which is fully compatible with JSON.

curl -H 'Accept: application/ld+json' 'https://scigraph.springernature.com/pub.10.1007/s40030-017-0216-0'

N-Triples is a line-based linked data format ideal for batch operations.

curl -H 'Accept: application/n-triples' 'https://scigraph.springernature.com/pub.10.1007/s40030-017-0216-0'

Turtle is a human-readable linked data format.

curl -H 'Accept: text/turtle' 'https://scigraph.springernature.com/pub.10.1007/s40030-017-0216-0'

RDF/XML is a standard XML format for linked data.

curl -H 'Accept: application/rdf+xml' 'https://scigraph.springernature.com/pub.10.1007/s40030-017-0216-0'


 

This table displays all metadata directly associated to this object as RDF triples.

149 TRIPLES      21 PREDICATES      110 URIs      102 LITERALS      6 BLANK NODES

Subject Predicate Object
1 sg:pub.10.1007/s40030-017-0216-0 schema:about anzsrc-for:09
2 anzsrc-for:0905
3 schema:author Na97cb46f33994c7ca646c330e7776d2f
4 schema:datePublished 2017-07-26
5 schema:datePublishedReg 2017-07-26
6 schema:description The lateral displacement of Reinforced Concrete (RC) frame building during an earthquake has an important impact on the structural stability and integrity. However, seismic analysis and design of RC building needs more concern due to its complex behavior as the performance of the structure links to the features of the system having many influencing parameters and other inherent uncertainties. The reliability approach takes into account the factors and uncertainty in design influencing the performance or response of the structure in which the safety level or the probability of failure could be ascertained. This present study, aims to assess the reliability of seismic performance of a four storey residential RC building seismically located in Zone-V as per the code provisions given in the Indian Standards IS: 1893-2002. The reliability assessment performed by deriving an explicit expression for maximum roof-lateral displacement as a failure function by regression method. A total of 319, four storey RC buildings were analyzed by linear static method using SAP2000. However, the change in the lateral-roof displacement with the variation of the parameters (column dimension, beam dimension, grade of concrete, floor height and total weight of the structure) was observed. A generalized relation established by regression method which could be used to estimate the expected lateral displacement owing to those selected parameters. A comparison made between the displacements obtained from analysis with that of the equation so formed. However, it shows that the proposed relation could be used directly to determine the expected maximum lateral displacement. The data obtained from the statistical computations was then used to obtain the probability of failure and the reliability.
7 schema:genre article
8 schema:inLanguage en
9 schema:isAccessibleForFree false
10 schema:isPartOf N300d1fbc37b24dd7b74d8d457315a0bc
11 N8247257457d645d1a78a6d6e27a4ccc1
12 sg:journal.1135971
13 schema:keywords Drift Reliability Assessment
14 Four Storey Frame Residential Building
15 Frame Residential Building
16 Indian Standards
17 RC buildings
18 Reinforced Concrete
19 SAP2000
20 Storey Frame Residential Building
21 account
22 analysis
23 approach
24 assessment
25 behavior
26 buildings
27 changes
28 code provisions
29 comparison
30 complex behavior
31 computation
32 concern
33 concrete
34 data
35 design
36 displacement
37 displacement owing
38 earthquakes
39 equations
40 expected maximum lateral displacement
41 explicit expressions
42 expression
43 factors
44 failure
45 failure function
46 features
47 function
48 generalized relation
49 impact
50 important impact
51 inherent uncertainty
52 integrity
53 lateral displacement
54 lateral displacement owing
55 lateral-roof displacement
56 levels
57 linear static method
58 loading
59 maximum lateral displacement
60 maximum roof-lateral displacement
61 method
62 more concern
63 multiple factors
64 owing
65 parameters
66 performance
67 present study
68 probability
69 probability of failure
70 provision
71 regression method
72 relation
73 reliability
74 reliability approach
75 reliability assessment
76 residential RC buildings
77 residential buildings
78 response
79 roof-lateral displacement
80 safety level
81 seismic analysis
82 seismic loading
83 seismic performance
84 stability
85 standards
86 static method
87 statistical computations
88 storey residential RC building
89 story RC building
90 structural stability
91 structure
92 study
93 system
94 total
95 uncertainty
96 variation
97 zone
98 schema:name Drift Reliability Assessment of a Four Storey Frame Residential Building Under Seismic Loading Considering Multiple Factors
99 schema:pagination 245-256
100 schema:productId N45b0da2daaa04452972f5a52ee3a6ad0
101 Ndfa79393ddb64b52a70ea18475472c2a
102 schema:sameAs https://app.dimensions.ai/details/publication/pub.1090898721
103 https://doi.org/10.1007/s40030-017-0216-0
104 schema:sdDatePublished 2021-11-01T18:31
105 schema:sdLicense https://scigraph.springernature.com/explorer/license/
106 schema:sdPublisher N65ca0120f5bc4f6daab713f265e40fcf
107 schema:url https://doi.org/10.1007/s40030-017-0216-0
108 sgo:license sg:explorer/license/
109 sgo:sdDataset articles
110 rdf:type schema:ScholarlyArticle
111 N1b0e1eb047ca4af09728f0a662a517ac schema:affiliation grid-institutes:grid.444720.1
112 schema:familyName Longmailai
113 schema:givenName Thaihamdau
114 rdf:type schema:Person
115 N300d1fbc37b24dd7b74d8d457315a0bc schema:volumeNumber 98
116 rdf:type schema:PublicationVolume
117 N45b0da2daaa04452972f5a52ee3a6ad0 schema:name doi
118 schema:value 10.1007/s40030-017-0216-0
119 rdf:type schema:PropertyValue
120 N65ca0120f5bc4f6daab713f265e40fcf schema:name Springer Nature - SN SciGraph project
121 rdf:type schema:Organization
122 N8247257457d645d1a78a6d6e27a4ccc1 schema:issueNumber 3
123 rdf:type schema:PublicationIssue
124 Na97cb46f33994c7ca646c330e7776d2f rdf:first sg:person.012767414161.53
125 rdf:rest Nd847902346344a1383e11d12f6b7253a
126 Nd847902346344a1383e11d12f6b7253a rdf:first N1b0e1eb047ca4af09728f0a662a517ac
127 rdf:rest rdf:nil
128 Ndfa79393ddb64b52a70ea18475472c2a schema:name dimensions_id
129 schema:value pub.1090898721
130 rdf:type schema:PropertyValue
131 anzsrc-for:09 schema:inDefinedTermSet anzsrc-for:
132 schema:name Engineering
133 rdf:type schema:DefinedTerm
134 anzsrc-for:0905 schema:inDefinedTermSet anzsrc-for:
135 schema:name Civil Engineering
136 rdf:type schema:DefinedTerm
137 sg:journal.1135971 schema:issn 2250-2149
138 2250-2157
139 schema:name Journal of The Institution of Engineers (India): Series A
140 schema:publisher Springer Nature
141 rdf:type schema:Periodical
142 sg:person.012767414161.53 schema:affiliation grid-institutes:grid.444720.1
143 schema:familyName Sil
144 schema:givenName Arjun
145 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.012767414161.53
146 rdf:type schema:Person
147 grid-institutes:grid.444720.1 schema:alternateName Department of Civil Engineering, National Institute of Technology Silchar, Silchar, Assam, India
148 schema:name Department of Civil Engineering, National Institute of Technology Silchar, Silchar, Assam, India
149 rdf:type schema:Organization
 




Preview window. Press ESC to close (or click here)


...