Impact of catheter down-sizing and power injector use on the amount of contrast medium delivered View Full Text


Ontology type: schema:ScholarlyArticle     


Article Info

DATE

2009-10-08

AUTHORS

Tsuyoshi Nozue, Ichiro Michishita, Ichiro Mizuguchi

ABSTRACT

The purpose of this study is to evaluate the effect of catheter down-sizing and power injector use on the amount of contrast medium delivered during diagnostic coronary angiography (CAG). We retrospectively studied 735 patients undergoing diagnostic CAG. Patients were divided into four groups according to catheter size [4 French (Fr) or 5 Fr] and the method of contrast injection (manual or power injection). Total contrast volume, procedure time, number of catheters used and angiogram quality were analyzed. Down-sizing catheters from 5 Fr to 4 Fr reduced the amount of contrast medium in both manual injection (from 153 ± 22 to 137 ± 17 ml, −10%, p < 0.0001) and power injection (from 135 ± 12 to 125 ± 16 ml, −7%, p < 0.0001). Introduction of power injection reduced the amount of contrast medium in both 4-Fr catheters (from 137 ± 17 to 125 ± 16 ml, −9%, p < 0.0001) and 5-Fr catheters (from 153 ± 22 to 135 ± 12 ml, −12%, p < 0.0001). A 28-ml (18%) reduction in contrast medium volume occurred when catheter down-sizing was combined with power injector use. Angiogram quality was not different among the four groups. Down-sizing the catheters from 5 Fr to 4 Fr and the use of a power injector reduced the amount of contrast medium delivered in CAG without reducing angiographic image quality. More... »

PAGES

24-28

Identifiers

URI

http://scigraph.springernature.com/pub.10.1007/s12928-009-0003-6

DOI

http://dx.doi.org/10.1007/s12928-009-0003-6

DIMENSIONS

https://app.dimensions.ai/details/publication/pub.1041165840

PUBMED

https://www.ncbi.nlm.nih.gov/pubmed/24122429


Indexing Status Check whether this publication has been indexed by Scopus and Web Of Science using the SN Indexing Status Tool
Incoming Citations Browse incoming citations for this publication using opencitations.net

JSON-LD is the canonical representation for SciGraph data.

TIP: You can open this SciGraph record using an external JSON-LD service: JSON-LD Playground Google SDTT

[
  {
    "@context": "https://springernature.github.io/scigraph/jsonld/sgcontext.json", 
    "about": [
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/11", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "name": "Medical and Health Sciences", 
        "type": "DefinedTerm"
      }, 
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/1103", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "name": "Clinical Sciences", 
        "type": "DefinedTerm"
      }
    ], 
    "author": [
      {
        "affiliation": {
          "alternateName": "Division of Cardiology, Department of Internal Medicine, Yokohama Sakae Kyosai Hospital, Federation of National Public Service Personnel Mutual Associations, 132 Katsura-cho, Sakae-ku, 247-8581, Yokohama, Japan", 
          "id": "http://www.grid.ac/institutes/grid.417368.f", 
          "name": [
            "Division of Cardiology, Department of Internal Medicine, Yokohama Sakae Kyosai Hospital, Federation of National Public Service Personnel Mutual Associations, 132 Katsura-cho, Sakae-ku, 247-8581, Yokohama, Japan"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Nozue", 
        "givenName": "Tsuyoshi", 
        "id": "sg:person.01033145125.12", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01033145125.12"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Division of Cardiology, Department of Internal Medicine, Yokohama Sakae Kyosai Hospital, Federation of National Public Service Personnel Mutual Associations, 132 Katsura-cho, Sakae-ku, 247-8581, Yokohama, Japan", 
          "id": "http://www.grid.ac/institutes/grid.417368.f", 
          "name": [
            "Division of Cardiology, Department of Internal Medicine, Yokohama Sakae Kyosai Hospital, Federation of National Public Service Personnel Mutual Associations, 132 Katsura-cho, Sakae-ku, 247-8581, Yokohama, Japan"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Michishita", 
        "givenName": "Ichiro", 
        "id": "sg:person.0732262025.70", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0732262025.70"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Division of Cardiology, Department of Internal Medicine, Yokohama Sakae Kyosai Hospital, Federation of National Public Service Personnel Mutual Associations, 132 Katsura-cho, Sakae-ku, 247-8581, Yokohama, Japan", 
          "id": "http://www.grid.ac/institutes/grid.417368.f", 
          "name": [
            "Division of Cardiology, Department of Internal Medicine, Yokohama Sakae Kyosai Hospital, Federation of National Public Service Personnel Mutual Associations, 132 Katsura-cho, Sakae-ku, 247-8581, Yokohama, Japan"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Mizuguchi", 
        "givenName": "Ichiro", 
        "id": "sg:person.0704042263.51", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0704042263.51"
        ], 
        "type": "Person"
      }
    ], 
    "datePublished": "2009-10-08", 
    "datePublishedReg": "2009-10-08", 
    "description": "The purpose of this study is to evaluate the effect of catheter down-sizing and power injector use on the amount of contrast medium delivered during diagnostic coronary angiography (CAG). We retrospectively studied 735 patients undergoing diagnostic CAG. Patients were divided into four groups according to catheter size [4 French (Fr) or 5 Fr] and the method of contrast injection (manual or power injection). Total contrast volume, procedure time, number of catheters used and angiogram quality were analyzed. Down-sizing catheters from 5 Fr to 4 Fr reduced the amount of contrast medium in both manual injection (from 153\u00a0\u00b1\u00a022 to 137\u00a0\u00b1\u00a017\u00a0ml, \u221210%, p\u00a0<\u00a00.0001) and power injection (from 135\u00a0\u00b1\u00a012 to 125\u00a0\u00b1\u00a016\u00a0ml, \u22127%, p\u00a0<\u00a00.0001). Introduction of power injection reduced the amount of contrast medium in both 4-Fr catheters (from 137\u00a0\u00b1\u00a017 to 125\u00a0\u00b1\u00a016\u00a0ml, \u22129%, p\u00a0<\u00a00.0001) and 5-Fr catheters (from 153\u00a0\u00b1\u00a022 to 135\u00a0\u00b1\u00a012\u00a0ml, \u221212%, p\u00a0<\u00a00.0001). A 28-ml (18%) reduction in contrast medium volume occurred when catheter down-sizing was combined with power injector use. Angiogram quality was not different among the four groups. Down-sizing the catheters from 5 Fr to 4 Fr and the use of a power injector reduced the amount of contrast medium delivered in CAG without reducing angiographic image quality.", 
    "genre": "article", 
    "id": "sg:pub.10.1007/s12928-009-0003-6", 
    "inLanguage": "en", 
    "isAccessibleForFree": false, 
    "isPartOf": [
      {
        "id": "sg:journal.1042779", 
        "issn": [
          "1868-4300", 
          "1868-4297"
        ], 
        "name": "Cardiovascular Intervention and Therapeutics", 
        "publisher": "Springer Nature", 
        "type": "Periodical"
      }, 
      {
        "issueNumber": "1", 
        "type": "PublicationIssue"
      }, 
      {
        "type": "PublicationVolume", 
        "volumeNumber": "25"
      }
    ], 
    "keywords": [
      "diagnostic coronary angiography", 
      "coronary angiography", 
      "contrast medium", 
      "impact of catheters", 
      "total contrast volume", 
      "number of catheters", 
      "contrast medium volume", 
      "Effect of Catheter", 
      "contrast volume", 
      "angiographic image quality", 
      "contrast injection", 
      "procedure time", 
      "catheter", 
      "catheter size", 
      "power injector", 
      "patients", 
      "injection", 
      "manual injection", 
      "angiogram quality", 
      "angiography", 
      "group", 
      "medium volume", 
      "use", 
      "volume", 
      "FR", 
      "quality", 
      "image quality", 
      "study", 
      "reduction", 
      "effect", 
      "amount", 
      "purpose", 
      "medium", 
      "number", 
      "time", 
      "impact", 
      "introduction", 
      "size", 
      "method", 
      "injector", 
      "power injection", 
      "sizing"
    ], 
    "name": "Impact of catheter down-sizing and power injector use on the amount of contrast medium delivered", 
    "pagination": "24-28", 
    "productId": [
      {
        "name": "dimensions_id", 
        "type": "PropertyValue", 
        "value": [
          "pub.1041165840"
        ]
      }, 
      {
        "name": "doi", 
        "type": "PropertyValue", 
        "value": [
          "10.1007/s12928-009-0003-6"
        ]
      }, 
      {
        "name": "pubmed_id", 
        "type": "PropertyValue", 
        "value": [
          "24122429"
        ]
      }
    ], 
    "sameAs": [
      "https://doi.org/10.1007/s12928-009-0003-6", 
      "https://app.dimensions.ai/details/publication/pub.1041165840"
    ], 
    "sdDataset": "articles", 
    "sdDatePublished": "2022-06-01T22:06", 
    "sdLicense": "https://scigraph.springernature.com/explorer/license/", 
    "sdPublisher": {
      "name": "Springer Nature - SN SciGraph project", 
      "type": "Organization"
    }, 
    "sdSource": "s3://com-springernature-scigraph/baseset/20220601/entities/gbq_results/article/article_480.jsonl", 
    "type": "ScholarlyArticle", 
    "url": "https://doi.org/10.1007/s12928-009-0003-6"
  }
]
 

Download the RDF metadata as:  json-ld nt turtle xml License info

HOW TO GET THIS DATA PROGRAMMATICALLY:

JSON-LD is a popular format for linked data which is fully compatible with JSON.

curl -H 'Accept: application/ld+json' 'https://scigraph.springernature.com/pub.10.1007/s12928-009-0003-6'

N-Triples is a line-based linked data format ideal for batch operations.

curl -H 'Accept: application/n-triples' 'https://scigraph.springernature.com/pub.10.1007/s12928-009-0003-6'

Turtle is a human-readable linked data format.

curl -H 'Accept: text/turtle' 'https://scigraph.springernature.com/pub.10.1007/s12928-009-0003-6'

RDF/XML is a standard XML format for linked data.

curl -H 'Accept: application/rdf+xml' 'https://scigraph.springernature.com/pub.10.1007/s12928-009-0003-6'


 

This table displays all metadata directly associated to this object as RDF triples.

118 TRIPLES      21 PREDICATES      68 URIs      60 LITERALS      7 BLANK NODES

Subject Predicate Object
1 sg:pub.10.1007/s12928-009-0003-6 schema:about anzsrc-for:11
2 anzsrc-for:1103
3 schema:author N09eba524366d415ba5357dcc0369d900
4 schema:datePublished 2009-10-08
5 schema:datePublishedReg 2009-10-08
6 schema:description The purpose of this study is to evaluate the effect of catheter down-sizing and power injector use on the amount of contrast medium delivered during diagnostic coronary angiography (CAG). We retrospectively studied 735 patients undergoing diagnostic CAG. Patients were divided into four groups according to catheter size [4 French (Fr) or 5 Fr] and the method of contrast injection (manual or power injection). Total contrast volume, procedure time, number of catheters used and angiogram quality were analyzed. Down-sizing catheters from 5 Fr to 4 Fr reduced the amount of contrast medium in both manual injection (from 153 ± 22 to 137 ± 17 ml, −10%, p < 0.0001) and power injection (from 135 ± 12 to 125 ± 16 ml, −7%, p < 0.0001). Introduction of power injection reduced the amount of contrast medium in both 4-Fr catheters (from 137 ± 17 to 125 ± 16 ml, −9%, p < 0.0001) and 5-Fr catheters (from 153 ± 22 to 135 ± 12 ml, −12%, p < 0.0001). A 28-ml (18%) reduction in contrast medium volume occurred when catheter down-sizing was combined with power injector use. Angiogram quality was not different among the four groups. Down-sizing the catheters from 5 Fr to 4 Fr and the use of a power injector reduced the amount of contrast medium delivered in CAG without reducing angiographic image quality.
7 schema:genre article
8 schema:inLanguage en
9 schema:isAccessibleForFree false
10 schema:isPartOf N36e2fe8eadb94f5a8444b8117a6f3300
11 N46f77426573b407892b6536630e17d3a
12 sg:journal.1042779
13 schema:keywords Effect of Catheter
14 FR
15 amount
16 angiogram quality
17 angiographic image quality
18 angiography
19 catheter
20 catheter size
21 contrast injection
22 contrast medium
23 contrast medium volume
24 contrast volume
25 coronary angiography
26 diagnostic coronary angiography
27 effect
28 group
29 image quality
30 impact
31 impact of catheters
32 injection
33 injector
34 introduction
35 manual injection
36 medium
37 medium volume
38 method
39 number
40 number of catheters
41 patients
42 power injection
43 power injector
44 procedure time
45 purpose
46 quality
47 reduction
48 size
49 sizing
50 study
51 time
52 total contrast volume
53 use
54 volume
55 schema:name Impact of catheter down-sizing and power injector use on the amount of contrast medium delivered
56 schema:pagination 24-28
57 schema:productId N0355a365da404a88ac7dd22728e3e00d
58 N6220fba2cc0e4ea385ef0a80df8abcb0
59 N997bb97cc5d04aa081b55c12fde4a685
60 schema:sameAs https://app.dimensions.ai/details/publication/pub.1041165840
61 https://doi.org/10.1007/s12928-009-0003-6
62 schema:sdDatePublished 2022-06-01T22:06
63 schema:sdLicense https://scigraph.springernature.com/explorer/license/
64 schema:sdPublisher N96ce402432d646e3a52b488f6f30a85b
65 schema:url https://doi.org/10.1007/s12928-009-0003-6
66 sgo:license sg:explorer/license/
67 sgo:sdDataset articles
68 rdf:type schema:ScholarlyArticle
69 N0355a365da404a88ac7dd22728e3e00d schema:name doi
70 schema:value 10.1007/s12928-009-0003-6
71 rdf:type schema:PropertyValue
72 N09eba524366d415ba5357dcc0369d900 rdf:first sg:person.01033145125.12
73 rdf:rest N2d61b1367f914e17af1fc3ff80e7d315
74 N2d61b1367f914e17af1fc3ff80e7d315 rdf:first sg:person.0732262025.70
75 rdf:rest N555706e264964c5ab67fdccf8036e59f
76 N36e2fe8eadb94f5a8444b8117a6f3300 schema:issueNumber 1
77 rdf:type schema:PublicationIssue
78 N46f77426573b407892b6536630e17d3a schema:volumeNumber 25
79 rdf:type schema:PublicationVolume
80 N555706e264964c5ab67fdccf8036e59f rdf:first sg:person.0704042263.51
81 rdf:rest rdf:nil
82 N6220fba2cc0e4ea385ef0a80df8abcb0 schema:name pubmed_id
83 schema:value 24122429
84 rdf:type schema:PropertyValue
85 N96ce402432d646e3a52b488f6f30a85b schema:name Springer Nature - SN SciGraph project
86 rdf:type schema:Organization
87 N997bb97cc5d04aa081b55c12fde4a685 schema:name dimensions_id
88 schema:value pub.1041165840
89 rdf:type schema:PropertyValue
90 anzsrc-for:11 schema:inDefinedTermSet anzsrc-for:
91 schema:name Medical and Health Sciences
92 rdf:type schema:DefinedTerm
93 anzsrc-for:1103 schema:inDefinedTermSet anzsrc-for:
94 schema:name Clinical Sciences
95 rdf:type schema:DefinedTerm
96 sg:journal.1042779 schema:issn 1868-4297
97 1868-4300
98 schema:name Cardiovascular Intervention and Therapeutics
99 schema:publisher Springer Nature
100 rdf:type schema:Periodical
101 sg:person.01033145125.12 schema:affiliation grid-institutes:grid.417368.f
102 schema:familyName Nozue
103 schema:givenName Tsuyoshi
104 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01033145125.12
105 rdf:type schema:Person
106 sg:person.0704042263.51 schema:affiliation grid-institutes:grid.417368.f
107 schema:familyName Mizuguchi
108 schema:givenName Ichiro
109 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0704042263.51
110 rdf:type schema:Person
111 sg:person.0732262025.70 schema:affiliation grid-institutes:grid.417368.f
112 schema:familyName Michishita
113 schema:givenName Ichiro
114 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0732262025.70
115 rdf:type schema:Person
116 grid-institutes:grid.417368.f schema:alternateName Division of Cardiology, Department of Internal Medicine, Yokohama Sakae Kyosai Hospital, Federation of National Public Service Personnel Mutual Associations, 132 Katsura-cho, Sakae-ku, 247-8581, Yokohama, Japan
117 schema:name Division of Cardiology, Department of Internal Medicine, Yokohama Sakae Kyosai Hospital, Federation of National Public Service Personnel Mutual Associations, 132 Katsura-cho, Sakae-ku, 247-8581, Yokohama, Japan
118 rdf:type schema:Organization
 




Preview window. Press ESC to close (or click here)


...