Ontology type: schema:ScholarlyArticle
2021-11-26
AUTHORSYasushi Wakabayashi, Masanori Kobayashi, Tomohide Ichikawa, Takashi Koyama, Hidetoshi Abe
ABSTRACTPurposeCardiac implantable electronic devices (CIEDs) offer diagnostic information such as device-measured physical activity (PA). Peak oxygen consumption (VO2) measured by cardiopulmonary exercise testing (CPET) is the most objective variable showing exercise capacity. The purpose of this study was to investigate the relationship between these 2 variables.MethodsWe retrospectively studied consecutive patients with CIEDs undergoing CPET between April 1, 2018, and January 31, 2021. These patients were divided into 2 groups: patients with peak VO2 ≤ 14 ml/kg/min (low peak VO2 group) and those showing peak VO2 > 14 ml/kg/min (high peak VO2 group). The peak device-measured PA was compared between the 2 groups. The relationship between the peak device-measured PA and peak VO2 was also investigated.ResultsThere were 50 and 51 patients in the low and high peak VO2 groups, respectively. The peak device-measured PA, which was expressed in units of hours/day, was significantly lower in the low peak VO2 group than in the high peak VO2 group (3.06, interquartile range [2.43–4.00] vs. 5.50, interquartile range [4.04–6.70] p < 0.01). The peak device-measured PA and peak VO2 showed a significant positive correlation (Spearman’s ρ = 0.53; p < 0.01). Furthermore, receiver operating characteristic curve analysis showed that a peak device-measured PA > 3.87 h/day could predict high peak VO2 (80.4%, sensitivity; 72.0%, specificity). In multivariate linear regression analysis, peak device-measured PA was an independent predictor of peak VO2 (regression coefficient, 0.61; 95% confidence interval, 0.33–0.89; p < 0.01).ConclusionsPeak device-measured PA was significantly associated with peak VO2. More... »
PAGES1-9
http://scigraph.springernature.com/pub.10.1007/s10840-021-01095-8
DOIhttp://dx.doi.org/10.1007/s10840-021-01095-8
DIMENSIONShttps://app.dimensions.ai/details/publication/pub.1143206940
PUBMEDhttps://www.ncbi.nlm.nih.gov/pubmed/34826015
JSON-LD is the canonical representation for SciGraph data.
TIP: You can open this SciGraph record using an external JSON-LD service: JSON-LD Playground Google SDTT
[
{
"@context": "https://springernature.github.io/scigraph/jsonld/sgcontext.json",
"about": [
{
"id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/11",
"inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/",
"name": "Medical and Health Sciences",
"type": "DefinedTerm"
},
{
"id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/1102",
"inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/",
"name": "Cardiorespiratory Medicine and Haematology",
"type": "DefinedTerm"
}
],
"author": [
{
"affiliation": {
"alternateName": "Department of Cardiovascular Medicine, Matsumoto Kyoritsu Hospital, 9-26 Habaue, 390-8505, Matsumoto City, Nagano, Japan",
"id": "http://www.grid.ac/institutes/None",
"name": [
"Department of Cardiovascular Medicine, Matsumoto Kyoritsu Hospital, 9-26 Habaue, 390-8505, Matsumoto City, Nagano, Japan"
],
"type": "Organization"
},
"familyName": "Wakabayashi",
"givenName": "Yasushi",
"id": "sg:person.0711503377.33",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0711503377.33"
],
"type": "Person"
},
{
"affiliation": {
"alternateName": "Department of Cardiovascular Medicine, Matsumoto Kyoritsu Hospital, 9-26 Habaue, 390-8505, Matsumoto City, Nagano, Japan",
"id": "http://www.grid.ac/institutes/None",
"name": [
"Department of Cardiovascular Medicine, Matsumoto Kyoritsu Hospital, 9-26 Habaue, 390-8505, Matsumoto City, Nagano, Japan"
],
"type": "Organization"
},
"familyName": "Kobayashi",
"givenName": "Masanori",
"id": "sg:person.015401557557.48",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.015401557557.48"
],
"type": "Person"
},
{
"affiliation": {
"alternateName": "Department of Cardiovascular Medicine, Matsumoto Kyoritsu Hospital, 9-26 Habaue, 390-8505, Matsumoto City, Nagano, Japan",
"id": "http://www.grid.ac/institutes/None",
"name": [
"Department of Cardiovascular Medicine, Matsumoto Kyoritsu Hospital, 9-26 Habaue, 390-8505, Matsumoto City, Nagano, Japan"
],
"type": "Organization"
},
"familyName": "Ichikawa",
"givenName": "Tomohide",
"id": "sg:person.016177140157.92",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.016177140157.92"
],
"type": "Person"
},
{
"affiliation": {
"alternateName": "Department of Cardiovascular Medicine, Matsumoto Kyoritsu Hospital, 9-26 Habaue, 390-8505, Matsumoto City, Nagano, Japan",
"id": "http://www.grid.ac/institutes/None",
"name": [
"Department of Cardiovascular Medicine, Matsumoto Kyoritsu Hospital, 9-26 Habaue, 390-8505, Matsumoto City, Nagano, Japan"
],
"type": "Organization"
},
"familyName": "Koyama",
"givenName": "Takashi",
"id": "sg:person.014006616557.62",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.014006616557.62"
],
"type": "Person"
},
{
"affiliation": {
"alternateName": "Department of Cardiovascular Medicine, Matsumoto Kyoritsu Hospital, 9-26 Habaue, 390-8505, Matsumoto City, Nagano, Japan",
"id": "http://www.grid.ac/institutes/None",
"name": [
"Department of Cardiovascular Medicine, Matsumoto Kyoritsu Hospital, 9-26 Habaue, 390-8505, Matsumoto City, Nagano, Japan"
],
"type": "Organization"
},
"familyName": "Abe",
"givenName": "Hidetoshi",
"id": "sg:person.07474066757.87",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.07474066757.87"
],
"type": "Person"
}
],
"citation": [
{
"id": "sg:pub.10.1007/s00380-021-01790-6",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1136447203",
"https://doi.org/10.1007/s00380-021-01790-6"
],
"type": "CreativeWork"
}
],
"datePublished": "2021-11-26",
"datePublishedReg": "2021-11-26",
"description": "PurposeCardiac implantable electronic devices (CIEDs) offer diagnostic information such as device-measured physical activity (PA). Peak oxygen consumption (VO2) measured by cardiopulmonary exercise testing (CPET) is the most objective variable showing exercise capacity. The purpose of this study was to investigate the relationship between these 2 variables.MethodsWe retrospectively studied consecutive patients with CIEDs undergoing CPET between April 1, 2018, and January 31, 2021. These patients were divided into 2 groups: patients with peak VO2\u2009\u2264\u200914\u00a0ml/kg/min (low peak VO2 group) and those showing peak VO2\u2009>\u200914\u00a0ml/kg/min (high peak VO2 group). The peak device-measured PA was compared between the 2 groups. The relationship between the peak device-measured PA and peak VO2 was also investigated.ResultsThere were 50 and 51 patients in the low and high peak VO2 groups, respectively. The peak device-measured PA, which was expressed in units of hours/day, was significantly lower in the low peak VO2 group than in the high peak VO2 group (3.06, interquartile range [2.43\u20134.00] vs. 5.50, interquartile range [4.04\u20136.70] p\u2009<\u20090.01). The peak device-measured PA and peak VO2 showed a significant positive correlation (Spearman\u2019s \u03c1\u2009=\u20090.53; p\u2009<\u20090.01). Furthermore, receiver operating characteristic curve analysis showed that a peak device-measured PA\u2009>\u20093.87\u00a0h/day could predict high peak VO2 (80.4%, sensitivity; 72.0%, specificity). In multivariate linear regression analysis, peak device-measured PA was an independent predictor of peak VO2 (regression coefficient, 0.61; 95% confidence interval, 0.33\u20130.89; p\u2009<\u20090.01).ConclusionsPeak device-measured PA was significantly associated with peak VO2.",
"genre": "article",
"id": "sg:pub.10.1007/s10840-021-01095-8",
"inLanguage": "en",
"isAccessibleForFree": false,
"isPartOf": [
{
"id": "sg:journal.1116996",
"issn": [
"1383-875X",
"1573-725X"
],
"name": "Journal of Interventional Cardiac Electrophysiology",
"publisher": "Springer Nature",
"type": "Periodical"
}
],
"keywords": [
"device-measured physical activity",
"cardiopulmonary exercise testing",
"peak oxygen consumption",
"peak VO2",
"physical activity",
"implantable electronic devices",
"exercise testing",
"multivariate linear regression analysis",
"higher peak VO2",
"cardiac implantable electronic devices",
"characteristic curve analysis",
"oxygen consumption",
"hours/day",
"exercise capacity",
"consecutive patients",
"independent predictors",
"patients",
"linear regression analysis",
"significant positive correlation",
"curve analysis",
"regression analysis",
"diagnostic information",
"positive correlation",
"group",
"VO2",
"days",
"objective variables",
"ResultsThere",
"CIED",
"MethodsWe",
"min",
"testing",
"predictors",
"activity",
"association",
"variables",
"study",
"relationship",
"consumption",
"correlation",
"analysis",
"purpose",
"units",
"receiver",
"capacity",
"information",
"devices",
"electronic devices"
],
"name": "Association of device-measured physical activity with peak oxygen consumption measured by cardiopulmonary exercise testing in patients with cardiac implantable electronic devices",
"pagination": "1-9",
"productId": [
{
"name": "dimensions_id",
"type": "PropertyValue",
"value": [
"pub.1143206940"
]
},
{
"name": "doi",
"type": "PropertyValue",
"value": [
"10.1007/s10840-021-01095-8"
]
},
{
"name": "pubmed_id",
"type": "PropertyValue",
"value": [
"34826015"
]
}
],
"sameAs": [
"https://doi.org/10.1007/s10840-021-01095-8",
"https://app.dimensions.ai/details/publication/pub.1143206940"
],
"sdDataset": "articles",
"sdDatePublished": "2022-05-10T10:29",
"sdLicense": "https://scigraph.springernature.com/explorer/license/",
"sdPublisher": {
"name": "Springer Nature - SN SciGraph project",
"type": "Organization"
},
"sdSource": "s3://com-springernature-scigraph/baseset/20220509/entities/gbq_results/article/article_908.jsonl",
"type": "ScholarlyArticle",
"url": "https://doi.org/10.1007/s10840-021-01095-8"
}
]
Download the RDF metadata as: json-ld nt turtle xml License info
JSON-LD is a popular format for linked data which is fully compatible with JSON.
curl -H 'Accept: application/ld+json' 'https://scigraph.springernature.com/pub.10.1007/s10840-021-01095-8'
N-Triples is a line-based linked data format ideal for batch operations.
curl -H 'Accept: application/n-triples' 'https://scigraph.springernature.com/pub.10.1007/s10840-021-01095-8'
Turtle is a human-readable linked data format.
curl -H 'Accept: text/turtle' 'https://scigraph.springernature.com/pub.10.1007/s10840-021-01095-8'
RDF/XML is a standard XML format for linked data.
curl -H 'Accept: application/rdf+xml' 'https://scigraph.springernature.com/pub.10.1007/s10840-021-01095-8'
This table displays all metadata directly associated to this object as RDF triples.
136 TRIPLES
22 PREDICATES
73 URIs
64 LITERALS
5 BLANK NODES
Subject | Predicate | Object | |
---|---|---|---|
1 | sg:pub.10.1007/s10840-021-01095-8 | schema:about | anzsrc-for:11 |
2 | ″ | ″ | anzsrc-for:1102 |
3 | ″ | schema:author | N8420c5ca678744a494528cd1833bd4f6 |
4 | ″ | schema:citation | sg:pub.10.1007/s00380-021-01790-6 |
5 | ″ | schema:datePublished | 2021-11-26 |
6 | ″ | schema:datePublishedReg | 2021-11-26 |
7 | ″ | schema:description | PurposeCardiac implantable electronic devices (CIEDs) offer diagnostic information such as device-measured physical activity (PA). Peak oxygen consumption (VO2) measured by cardiopulmonary exercise testing (CPET) is the most objective variable showing exercise capacity. The purpose of this study was to investigate the relationship between these 2 variables.MethodsWe retrospectively studied consecutive patients with CIEDs undergoing CPET between April 1, 2018, and January 31, 2021. These patients were divided into 2 groups: patients with peak VO2 ≤ 14 ml/kg/min (low peak VO2 group) and those showing peak VO2 > 14 ml/kg/min (high peak VO2 group). The peak device-measured PA was compared between the 2 groups. The relationship between the peak device-measured PA and peak VO2 was also investigated.ResultsThere were 50 and 51 patients in the low and high peak VO2 groups, respectively. The peak device-measured PA, which was expressed in units of hours/day, was significantly lower in the low peak VO2 group than in the high peak VO2 group (3.06, interquartile range [2.43–4.00] vs. 5.50, interquartile range [4.04–6.70] p < 0.01). The peak device-measured PA and peak VO2 showed a significant positive correlation (Spearman’s ρ = 0.53; p < 0.01). Furthermore, receiver operating characteristic curve analysis showed that a peak device-measured PA > 3.87 h/day could predict high peak VO2 (80.4%, sensitivity; 72.0%, specificity). In multivariate linear regression analysis, peak device-measured PA was an independent predictor of peak VO2 (regression coefficient, 0.61; 95% confidence interval, 0.33–0.89; p < 0.01).ConclusionsPeak device-measured PA was significantly associated with peak VO2. |
8 | ″ | schema:genre | article |
9 | ″ | schema:inLanguage | en |
10 | ″ | schema:isAccessibleForFree | false |
11 | ″ | schema:isPartOf | sg:journal.1116996 |
12 | ″ | schema:keywords | CIED |
13 | ″ | ″ | MethodsWe |
14 | ″ | ″ | ResultsThere |
15 | ″ | ″ | VO2 |
16 | ″ | ″ | activity |
17 | ″ | ″ | analysis |
18 | ″ | ″ | association |
19 | ″ | ″ | capacity |
20 | ″ | ″ | cardiac implantable electronic devices |
21 | ″ | ″ | cardiopulmonary exercise testing |
22 | ″ | ″ | characteristic curve analysis |
23 | ″ | ″ | consecutive patients |
24 | ″ | ″ | consumption |
25 | ″ | ″ | correlation |
26 | ″ | ″ | curve analysis |
27 | ″ | ″ | days |
28 | ″ | ″ | device-measured physical activity |
29 | ″ | ″ | devices |
30 | ″ | ″ | diagnostic information |
31 | ″ | ″ | electronic devices |
32 | ″ | ″ | exercise capacity |
33 | ″ | ″ | exercise testing |
34 | ″ | ″ | group |
35 | ″ | ″ | higher peak VO2 |
36 | ″ | ″ | hours/day |
37 | ″ | ″ | implantable electronic devices |
38 | ″ | ″ | independent predictors |
39 | ″ | ″ | information |
40 | ″ | ″ | linear regression analysis |
41 | ″ | ″ | min |
42 | ″ | ″ | multivariate linear regression analysis |
43 | ″ | ″ | objective variables |
44 | ″ | ″ | oxygen consumption |
45 | ″ | ″ | patients |
46 | ″ | ″ | peak VO2 |
47 | ″ | ″ | peak oxygen consumption |
48 | ″ | ″ | physical activity |
49 | ″ | ″ | positive correlation |
50 | ″ | ″ | predictors |
51 | ″ | ″ | purpose |
52 | ″ | ″ | receiver |
53 | ″ | ″ | regression analysis |
54 | ″ | ″ | relationship |
55 | ″ | ″ | significant positive correlation |
56 | ″ | ″ | study |
57 | ″ | ″ | testing |
58 | ″ | ″ | units |
59 | ″ | ″ | variables |
60 | ″ | schema:name | Association of device-measured physical activity with peak oxygen consumption measured by cardiopulmonary exercise testing in patients with cardiac implantable electronic devices |
61 | ″ | schema:pagination | 1-9 |
62 | ″ | schema:productId | N391f37d32e304156af35f98f41c2240d |
63 | ″ | ″ | N8d5647fb2ace4af89a4e455ae5ae5196 |
64 | ″ | ″ | Nc7bf7f5cd1574d738e07ba3056ab043e |
65 | ″ | schema:sameAs | https://app.dimensions.ai/details/publication/pub.1143206940 |
66 | ″ | ″ | https://doi.org/10.1007/s10840-021-01095-8 |
67 | ″ | schema:sdDatePublished | 2022-05-10T10:29 |
68 | ″ | schema:sdLicense | https://scigraph.springernature.com/explorer/license/ |
69 | ″ | schema:sdPublisher | N3abe8b3a3e404527b21384b5a51491d9 |
70 | ″ | schema:url | https://doi.org/10.1007/s10840-021-01095-8 |
71 | ″ | sgo:license | sg:explorer/license/ |
72 | ″ | sgo:sdDataset | articles |
73 | ″ | rdf:type | schema:ScholarlyArticle |
74 | N391f37d32e304156af35f98f41c2240d | schema:name | dimensions_id |
75 | ″ | schema:value | pub.1143206940 |
76 | ″ | rdf:type | schema:PropertyValue |
77 | N3abe8b3a3e404527b21384b5a51491d9 | schema:name | Springer Nature - SN SciGraph project |
78 | ″ | rdf:type | schema:Organization |
79 | N3deba2c30d7c43f7ac695a6ec589dcf0 | rdf:first | sg:person.015401557557.48 |
80 | ″ | rdf:rest | N443efd89ccf64783800f57e72bdd6a1b |
81 | N443efd89ccf64783800f57e72bdd6a1b | rdf:first | sg:person.016177140157.92 |
82 | ″ | rdf:rest | N4b4c698de3e642269d09c568864f182b |
83 | N4b4c698de3e642269d09c568864f182b | rdf:first | sg:person.014006616557.62 |
84 | ″ | rdf:rest | Nbd0e4ceb204b4fd4affa615f0611d9e6 |
85 | N8420c5ca678744a494528cd1833bd4f6 | rdf:first | sg:person.0711503377.33 |
86 | ″ | rdf:rest | N3deba2c30d7c43f7ac695a6ec589dcf0 |
87 | N8d5647fb2ace4af89a4e455ae5ae5196 | schema:name | doi |
88 | ″ | schema:value | 10.1007/s10840-021-01095-8 |
89 | ″ | rdf:type | schema:PropertyValue |
90 | Nbd0e4ceb204b4fd4affa615f0611d9e6 | rdf:first | sg:person.07474066757.87 |
91 | ″ | rdf:rest | rdf:nil |
92 | Nc7bf7f5cd1574d738e07ba3056ab043e | schema:name | pubmed_id |
93 | ″ | schema:value | 34826015 |
94 | ″ | rdf:type | schema:PropertyValue |
95 | anzsrc-for:11 | schema:inDefinedTermSet | anzsrc-for: |
96 | ″ | schema:name | Medical and Health Sciences |
97 | ″ | rdf:type | schema:DefinedTerm |
98 | anzsrc-for:1102 | schema:inDefinedTermSet | anzsrc-for: |
99 | ″ | schema:name | Cardiorespiratory Medicine and Haematology |
100 | ″ | rdf:type | schema:DefinedTerm |
101 | sg:journal.1116996 | schema:issn | 1383-875X |
102 | ″ | ″ | 1573-725X |
103 | ″ | schema:name | Journal of Interventional Cardiac Electrophysiology |
104 | ″ | schema:publisher | Springer Nature |
105 | ″ | rdf:type | schema:Periodical |
106 | sg:person.014006616557.62 | schema:affiliation | grid-institutes:None |
107 | ″ | schema:familyName | Koyama |
108 | ″ | schema:givenName | Takashi |
109 | ″ | schema:sameAs | https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.014006616557.62 |
110 | ″ | rdf:type | schema:Person |
111 | sg:person.015401557557.48 | schema:affiliation | grid-institutes:None |
112 | ″ | schema:familyName | Kobayashi |
113 | ″ | schema:givenName | Masanori |
114 | ″ | schema:sameAs | https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.015401557557.48 |
115 | ″ | rdf:type | schema:Person |
116 | sg:person.016177140157.92 | schema:affiliation | grid-institutes:None |
117 | ″ | schema:familyName | Ichikawa |
118 | ″ | schema:givenName | Tomohide |
119 | ″ | schema:sameAs | https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.016177140157.92 |
120 | ″ | rdf:type | schema:Person |
121 | sg:person.0711503377.33 | schema:affiliation | grid-institutes:None |
122 | ″ | schema:familyName | Wakabayashi |
123 | ″ | schema:givenName | Yasushi |
124 | ″ | schema:sameAs | https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0711503377.33 |
125 | ″ | rdf:type | schema:Person |
126 | sg:person.07474066757.87 | schema:affiliation | grid-institutes:None |
127 | ″ | schema:familyName | Abe |
128 | ″ | schema:givenName | Hidetoshi |
129 | ″ | schema:sameAs | https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.07474066757.87 |
130 | ″ | rdf:type | schema:Person |
131 | sg:pub.10.1007/s00380-021-01790-6 | schema:sameAs | https://app.dimensions.ai/details/publication/pub.1136447203 |
132 | ″ | ″ | https://doi.org/10.1007/s00380-021-01790-6 |
133 | ″ | rdf:type | schema:CreativeWork |
134 | grid-institutes:None | schema:alternateName | Department of Cardiovascular Medicine, Matsumoto Kyoritsu Hospital, 9-26 Habaue, 390-8505, Matsumoto City, Nagano, Japan |
135 | ″ | schema:name | Department of Cardiovascular Medicine, Matsumoto Kyoritsu Hospital, 9-26 Habaue, 390-8505, Matsumoto City, Nagano, Japan |
136 | ″ | rdf:type | schema:Organization |