Development of the High-Temperature Dew-Point Generator Over the Past 15 Years View Full Text


Ontology type: schema:ScholarlyArticle     


Article Info

DATE

2017-10

AUTHORS

R. Bosma, J. Nielsen, A. Peruzzi

ABSTRACT

At VSL a humidity generator was designed and constructed in the early 1990s. This generator was of the re-circulating-single-pressure type. Over the years, the generator has been thoroughly revised and several critical components have been replaced. Among others the pre-saturator and the change from re-circulation to single-pass mode. Validating experiments showed that the range of the new setup could be extended from 70∘C to 95∘C dew-point temperature, and the last modification allows an uncertainty of 0.048∘C (k = 2) at the maximum temperature. In 2009 the setup was used in the Euramet-T-K8 humidity intercomparison at temperatures up to 95∘C. In the period from 2003 to 2015, four state-of-the-art chilled mirror hygrometers were regularly calibrated with the generator. One of these was also calibrated with the primary dew-point standards of several other European National Metrology Institutes, which made it possible to link the VSL generator to the generators used in these institutes. An analysis of the results of these calibrations shows an agreement in calibration capabilities within 0.01∘C with PTB and NPL. More... »

PAGES

161

References to SciGraph publications

Identifiers

URI

http://scigraph.springernature.com/pub.10.1007/s10765-017-2291-x

DOI

http://dx.doi.org/10.1007/s10765-017-2291-x

DIMENSIONS

https://app.dimensions.ai/details/publication/pub.1091496833


Indexing Status Check whether this publication has been indexed by Scopus and Web Of Science using the SN Indexing Status Tool
Incoming Citations Browse incoming citations for this publication using opencitations.net

JSON-LD is the canonical representation for SciGraph data.

TIP: You can open this SciGraph record using an external JSON-LD service: JSON-LD Playground Google SDTT

[
  {
    "@context": "https://springernature.github.io/scigraph/jsonld/sgcontext.json", 
    "about": [
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/1402", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "name": "Applied Economics", 
        "type": "DefinedTerm"
      }, 
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/14", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "name": "Economics", 
        "type": "DefinedTerm"
      }
    ], 
    "author": [
      {
        "affiliation": {
          "alternateName": "Van Swinden Laboratorium", 
          "id": "https://www.grid.ac/institutes/grid.438979.8", 
          "name": [
            "Dutch Metrology Institute, VSL, Delft, The Netherlands"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Bosma", 
        "givenName": "R.", 
        "id": "sg:person.012305416553.86", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.012305416553.86"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Danish Technological Institute", 
          "id": "https://www.grid.ac/institutes/grid.423962.8", 
          "name": [
            "Danish Technological Institute, DTI, Aarhus, Denmark"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Nielsen", 
        "givenName": "J.", 
        "id": "sg:person.07756210507.96", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.07756210507.96"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Van Swinden Laboratorium", 
          "id": "https://www.grid.ac/institutes/grid.438979.8", 
          "name": [
            "Dutch Metrology Institute, VSL, Delft, The Netherlands"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Peruzzi", 
        "givenName": "A.", 
        "id": "sg:person.07416056003.93", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.07416056003.93"
        ], 
        "type": "Person"
      }
    ], 
    "citation": [
      {
        "id": "sg:pub.10.1007/s10765-014-1596-2", 
        "sameAs": [
          "https://app.dimensions.ai/details/publication/pub.1003298501", 
          "https://doi.org/10.1007/s10765-014-1596-2"
        ], 
        "type": "CreativeWork"
      }, 
      {
        "id": "sg:pub.10.1007/s10765-012-1214-0", 
        "sameAs": [
          "https://app.dimensions.ai/details/publication/pub.1039081252", 
          "https://doi.org/10.1007/s10765-012-1214-0"
        ], 
        "type": "CreativeWork"
      }, 
      {
        "id": "https://doi.org/10.1088/0026-1394/41/3/009", 
        "sameAs": [
          "https://app.dimensions.ai/details/publication/pub.1058978849"
        ], 
        "type": "CreativeWork"
      }, 
      {
        "id": "https://doi.org/10.1088/0026-1394/52/1a/03005", 
        "sameAs": [
          "https://app.dimensions.ai/details/publication/pub.1058980839"
        ], 
        "type": "CreativeWork"
      }
    ], 
    "datePublished": "2017-10", 
    "datePublishedReg": "2017-10-01", 
    "description": "At VSL a humidity generator was designed and constructed in the early 1990s. This generator was of the re-circulating-single-pressure type. Over the years, the generator has been thoroughly revised and several critical components have been replaced. Among others the pre-saturator and the change from re-circulation to single-pass mode. Validating experiments showed that the range of the new setup could be extended from 70\u2218C to 95\u2218C dew-point temperature, and the last modification allows an uncertainty of 0.048\u2218C (k = 2) at the maximum temperature. In 2009 the setup was used in the Euramet-T-K8 humidity intercomparison at temperatures up to 95\u2218C. In the period from 2003 to 2015, four state-of-the-art chilled mirror hygrometers were regularly calibrated with the generator. One of these was also calibrated with the primary dew-point standards of several other European National Metrology Institutes, which made it possible to link the VSL generator to the generators used in these institutes. An analysis of the results of these calibrations shows an agreement in calibration capabilities within 0.01\u2218C with PTB and NPL.", 
    "genre": "non_research_article", 
    "id": "sg:pub.10.1007/s10765-017-2291-x", 
    "inLanguage": [
      "en"
    ], 
    "isAccessibleForFree": false, 
    "isPartOf": [
      {
        "id": "sg:journal.1043587", 
        "issn": [
          "0195-928X", 
          "1572-9567"
        ], 
        "name": "International Journal of Thermophysics", 
        "type": "Periodical"
      }, 
      {
        "issueNumber": "10", 
        "type": "PublicationIssue"
      }, 
      {
        "type": "PublicationVolume", 
        "volumeNumber": "38"
      }
    ], 
    "name": "Development of the High-Temperature Dew-Point Generator Over the Past 15 Years", 
    "pagination": "161", 
    "productId": [
      {
        "name": "readcube_id", 
        "type": "PropertyValue", 
        "value": [
          "4380f5cd3383a51ed4daf99af41e7dd4960e3ca732dae8c2eb6dc3b827b4da20"
        ]
      }, 
      {
        "name": "doi", 
        "type": "PropertyValue", 
        "value": [
          "10.1007/s10765-017-2291-x"
        ]
      }, 
      {
        "name": "dimensions_id", 
        "type": "PropertyValue", 
        "value": [
          "pub.1091496833"
        ]
      }
    ], 
    "sameAs": [
      "https://doi.org/10.1007/s10765-017-2291-x", 
      "https://app.dimensions.ai/details/publication/pub.1091496833"
    ], 
    "sdDataset": "articles", 
    "sdDatePublished": "2019-04-11T09:54", 
    "sdLicense": "https://scigraph.springernature.com/explorer/license/", 
    "sdPublisher": {
      "name": "Springer Nature - SN SciGraph project", 
      "type": "Organization"
    }, 
    "sdSource": "s3://com-uberresearch-data-dimensions-target-20181106-alternative/cleanup/v134/2549eaecd7973599484d7c17b260dba0a4ecb94b/merge/v9/a6c9fde33151104705d4d7ff012ea9563521a3ce/jats-lookup/v90/0000000347_0000000347/records_89798_00000003.jsonl", 
    "type": "ScholarlyArticle", 
    "url": "http://link.springer.com/10.1007%2Fs10765-017-2291-x"
  }
]
 

Download the RDF metadata as:  json-ld nt turtle xml License info

HOW TO GET THIS DATA PROGRAMMATICALLY:

JSON-LD is a popular format for linked data which is fully compatible with JSON.

curl -H 'Accept: application/ld+json' 'https://scigraph.springernature.com/pub.10.1007/s10765-017-2291-x'

N-Triples is a line-based linked data format ideal for batch operations.

curl -H 'Accept: application/n-triples' 'https://scigraph.springernature.com/pub.10.1007/s10765-017-2291-x'

Turtle is a human-readable linked data format.

curl -H 'Accept: text/turtle' 'https://scigraph.springernature.com/pub.10.1007/s10765-017-2291-x'

RDF/XML is a standard XML format for linked data.

curl -H 'Accept: application/rdf+xml' 'https://scigraph.springernature.com/pub.10.1007/s10765-017-2291-x'


 

This table displays all metadata directly associated to this object as RDF triples.

92 TRIPLES      21 PREDICATES      31 URIs      19 LITERALS      7 BLANK NODES

Subject Predicate Object
1 sg:pub.10.1007/s10765-017-2291-x schema:about anzsrc-for:14
2 anzsrc-for:1402
3 schema:author Ndb89bd46065d4600b0f28760871325d3
4 schema:citation sg:pub.10.1007/s10765-012-1214-0
5 sg:pub.10.1007/s10765-014-1596-2
6 https://doi.org/10.1088/0026-1394/41/3/009
7 https://doi.org/10.1088/0026-1394/52/1a/03005
8 schema:datePublished 2017-10
9 schema:datePublishedReg 2017-10-01
10 schema:description At VSL a humidity generator was designed and constructed in the early 1990s. This generator was of the re-circulating-single-pressure type. Over the years, the generator has been thoroughly revised and several critical components have been replaced. Among others the pre-saturator and the change from re-circulation to single-pass mode. Validating experiments showed that the range of the new setup could be extended from 70∘C to 95∘C dew-point temperature, and the last modification allows an uncertainty of 0.048∘C (k = 2) at the maximum temperature. In 2009 the setup was used in the Euramet-T-K8 humidity intercomparison at temperatures up to 95∘C. In the period from 2003 to 2015, four state-of-the-art chilled mirror hygrometers were regularly calibrated with the generator. One of these was also calibrated with the primary dew-point standards of several other European National Metrology Institutes, which made it possible to link the VSL generator to the generators used in these institutes. An analysis of the results of these calibrations shows an agreement in calibration capabilities within 0.01∘C with PTB and NPL.
11 schema:genre non_research_article
12 schema:inLanguage en
13 schema:isAccessibleForFree false
14 schema:isPartOf N38c04ec34346471cb4273c383335d075
15 N6a419fbc14524cd990a0106d86469fe3
16 sg:journal.1043587
17 schema:name Development of the High-Temperature Dew-Point Generator Over the Past 15 Years
18 schema:pagination 161
19 schema:productId N2b02818ffa154944a62a5137584dd79d
20 N7c1eaccae4bd4577a7a57abab67b5a16
21 Nc41dd2fa7ee54036b2bc73bffb9f5266
22 schema:sameAs https://app.dimensions.ai/details/publication/pub.1091496833
23 https://doi.org/10.1007/s10765-017-2291-x
24 schema:sdDatePublished 2019-04-11T09:54
25 schema:sdLicense https://scigraph.springernature.com/explorer/license/
26 schema:sdPublisher N6e7d53220fa54a158107b1fe76542409
27 schema:url http://link.springer.com/10.1007%2Fs10765-017-2291-x
28 sgo:license sg:explorer/license/
29 sgo:sdDataset articles
30 rdf:type schema:ScholarlyArticle
31 N29cc2665dcf9429a859248949e024809 rdf:first sg:person.07416056003.93
32 rdf:rest rdf:nil
33 N2b02818ffa154944a62a5137584dd79d schema:name readcube_id
34 schema:value 4380f5cd3383a51ed4daf99af41e7dd4960e3ca732dae8c2eb6dc3b827b4da20
35 rdf:type schema:PropertyValue
36 N38c04ec34346471cb4273c383335d075 schema:issueNumber 10
37 rdf:type schema:PublicationIssue
38 N6a419fbc14524cd990a0106d86469fe3 schema:volumeNumber 38
39 rdf:type schema:PublicationVolume
40 N6e7d53220fa54a158107b1fe76542409 schema:name Springer Nature - SN SciGraph project
41 rdf:type schema:Organization
42 N720d1ff3848d47b58034c21f237942bc rdf:first sg:person.07756210507.96
43 rdf:rest N29cc2665dcf9429a859248949e024809
44 N7c1eaccae4bd4577a7a57abab67b5a16 schema:name doi
45 schema:value 10.1007/s10765-017-2291-x
46 rdf:type schema:PropertyValue
47 Nc41dd2fa7ee54036b2bc73bffb9f5266 schema:name dimensions_id
48 schema:value pub.1091496833
49 rdf:type schema:PropertyValue
50 Ndb89bd46065d4600b0f28760871325d3 rdf:first sg:person.012305416553.86
51 rdf:rest N720d1ff3848d47b58034c21f237942bc
52 anzsrc-for:14 schema:inDefinedTermSet anzsrc-for:
53 schema:name Economics
54 rdf:type schema:DefinedTerm
55 anzsrc-for:1402 schema:inDefinedTermSet anzsrc-for:
56 schema:name Applied Economics
57 rdf:type schema:DefinedTerm
58 sg:journal.1043587 schema:issn 0195-928X
59 1572-9567
60 schema:name International Journal of Thermophysics
61 rdf:type schema:Periodical
62 sg:person.012305416553.86 schema:affiliation https://www.grid.ac/institutes/grid.438979.8
63 schema:familyName Bosma
64 schema:givenName R.
65 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.012305416553.86
66 rdf:type schema:Person
67 sg:person.07416056003.93 schema:affiliation https://www.grid.ac/institutes/grid.438979.8
68 schema:familyName Peruzzi
69 schema:givenName A.
70 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.07416056003.93
71 rdf:type schema:Person
72 sg:person.07756210507.96 schema:affiliation https://www.grid.ac/institutes/grid.423962.8
73 schema:familyName Nielsen
74 schema:givenName J.
75 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.07756210507.96
76 rdf:type schema:Person
77 sg:pub.10.1007/s10765-012-1214-0 schema:sameAs https://app.dimensions.ai/details/publication/pub.1039081252
78 https://doi.org/10.1007/s10765-012-1214-0
79 rdf:type schema:CreativeWork
80 sg:pub.10.1007/s10765-014-1596-2 schema:sameAs https://app.dimensions.ai/details/publication/pub.1003298501
81 https://doi.org/10.1007/s10765-014-1596-2
82 rdf:type schema:CreativeWork
83 https://doi.org/10.1088/0026-1394/41/3/009 schema:sameAs https://app.dimensions.ai/details/publication/pub.1058978849
84 rdf:type schema:CreativeWork
85 https://doi.org/10.1088/0026-1394/52/1a/03005 schema:sameAs https://app.dimensions.ai/details/publication/pub.1058980839
86 rdf:type schema:CreativeWork
87 https://www.grid.ac/institutes/grid.423962.8 schema:alternateName Danish Technological Institute
88 schema:name Danish Technological Institute, DTI, Aarhus, Denmark
89 rdf:type schema:Organization
90 https://www.grid.ac/institutes/grid.438979.8 schema:alternateName Van Swinden Laboratorium
91 schema:name Dutch Metrology Institute, VSL, Delft, The Netherlands
92 rdf:type schema:Organization
 




Preview window. Press ESC to close (or click here)


...