Cerebral Venous Thrombosis: Diagnostic Features of Phase-Contrast MR Angiography View Full Text


Ontology type: schema:ScholarlyArticle     


Article Info

DATE

2011-09-23

AUTHORS

A. A. Tulupov, L. A. Savelyeva, O. B. Bogomyakova, Yu. A. Prygova

ABSTRACT

The estimation of blood flow velocity in cerebral veins and sinuses by ultrasound is limited because of technical factors that make visualization of the vessels near the acoustic windows of the skull difficult. The common quality of cerebral venous thrombosis (CVT) is associated with the poorly characterized imaging finding of parenchymal abnormalities. Phase-contrast magnetic resonance angiography (PC MRA) has offered some insight into these manifestations. The purpose of our research is to determine the ability of PC MRA to aid in the assessment of large cerebral sinuses and internal jugular veins, as well as to provide reference data for flow velocity in patients with CVT. We describe here the main clinical features and the MRI characteristics of collateral drainage and flow velocity data in patients with CVT. More... »

PAGES

551-560

Identifiers

URI

http://scigraph.springernature.com/pub.10.1007/s00723-011-0261-1

DOI

http://dx.doi.org/10.1007/s00723-011-0261-1

DIMENSIONS

https://app.dimensions.ai/details/publication/pub.1048311755


Indexing Status Check whether this publication has been indexed by Scopus and Web Of Science using the SN Indexing Status Tool
Incoming Citations Browse incoming citations for this publication using opencitations.net

JSON-LD is the canonical representation for SciGraph data.

TIP: You can open this SciGraph record using an external JSON-LD service: JSON-LD Playground Google SDTT

[
  {
    "@context": "https://springernature.github.io/scigraph/jsonld/sgcontext.json", 
    "about": [
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/02", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "name": "Physical Sciences", 
        "type": "DefinedTerm"
      }, 
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/03", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "name": "Chemical Sciences", 
        "type": "DefinedTerm"
      }, 
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/0202", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "name": "Atomic, Molecular, Nuclear, Particle and Plasma Physics", 
        "type": "DefinedTerm"
      }, 
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/0301", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "name": "Analytical Chemistry", 
        "type": "DefinedTerm"
      }, 
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/0306", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "name": "Physical Chemistry (incl. Structural)", 
        "type": "DefinedTerm"
      }
    ], 
    "author": [
      {
        "affiliation": {
          "alternateName": "\u201cMRT Technologies\u201d Department, Laboratory of Medical Diagnostic, International Tomography Center, Siberian Branch of the Russian Academy of Sciences, Institutskaya st. 3a, 630090, Novosibirsk, Russian Federation", 
          "id": "http://www.grid.ac/institutes/grid.415877.8", 
          "name": [
            "\u201cMRT Technologies\u201d Department, Laboratory of Medical Diagnostic, International Tomography Center, Siberian Branch of the Russian Academy of Sciences, Institutskaya st. 3a, 630090, Novosibirsk, Russian Federation"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Tulupov", 
        "givenName": "A. A.", 
        "id": "sg:person.01142753177.59", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01142753177.59"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "\u201cMRT Technologies\u201d Department, Laboratory of Medical Diagnostic, International Tomography Center, Siberian Branch of the Russian Academy of Sciences, Institutskaya st. 3a, 630090, Novosibirsk, Russian Federation", 
          "id": "http://www.grid.ac/institutes/grid.415877.8", 
          "name": [
            "\u201cMRT Technologies\u201d Department, Laboratory of Medical Diagnostic, International Tomography Center, Siberian Branch of the Russian Academy of Sciences, Institutskaya st. 3a, 630090, Novosibirsk, Russian Federation"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Savelyeva", 
        "givenName": "L. A.", 
        "id": "sg:person.011154451231.04", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.011154451231.04"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "\u201cMRT Technologies\u201d Department, Laboratory of Medical Diagnostic, International Tomography Center, Siberian Branch of the Russian Academy of Sciences, Institutskaya st. 3a, 630090, Novosibirsk, Russian Federation", 
          "id": "http://www.grid.ac/institutes/grid.415877.8", 
          "name": [
            "\u201cMRT Technologies\u201d Department, Laboratory of Medical Diagnostic, International Tomography Center, Siberian Branch of the Russian Academy of Sciences, Institutskaya st. 3a, 630090, Novosibirsk, Russian Federation"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Bogomyakova", 
        "givenName": "O. B.", 
        "id": "sg:person.0714612513.30", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0714612513.30"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Medicine Department, Novosibirsk State University, Pirogova st. 2, 630090, Novosibirsk, Russian Federation", 
          "id": "http://www.grid.ac/institutes/grid.4605.7", 
          "name": [
            "Medicine Department, Novosibirsk State University, Pirogova st. 2, 630090, Novosibirsk, Russian Federation"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Prygova", 
        "givenName": "Yu. A.", 
        "id": "sg:person.015535314231.28", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.015535314231.28"
        ], 
        "type": "Person"
      }
    ], 
    "datePublished": "2011-09-23", 
    "datePublishedReg": "2011-09-23", 
    "description": "The estimation of blood flow velocity in cerebral veins and sinuses by ultrasound is limited because of technical factors that make visualization of the vessels near the acoustic windows of the skull difficult. The common quality of cerebral venous thrombosis (CVT) is associated with the poorly characterized imaging finding of parenchymal abnormalities. Phase-contrast magnetic resonance angiography (PC MRA) has offered some insight into these manifestations. The purpose of our research is to determine the ability of PC MRA to aid in the assessment of large cerebral sinuses and internal jugular veins, as well as to provide reference data for flow velocity in patients with CVT. We describe here the main clinical features and the MRI characteristics of collateral drainage and flow velocity data in patients with CVT.", 
    "genre": "article", 
    "id": "sg:pub.10.1007/s00723-011-0261-1", 
    "inLanguage": "en", 
    "isAccessibleForFree": false, 
    "isPartOf": [
      {
        "id": "sg:journal.1102112", 
        "issn": [
          "0937-9347", 
          "1613-7507"
        ], 
        "name": "Applied Magnetic Resonance", 
        "publisher": "Springer Nature", 
        "type": "Periodical"
      }, 
      {
        "issueNumber": "2-4", 
        "type": "PublicationIssue"
      }, 
      {
        "type": "PublicationVolume", 
        "volumeNumber": "41"
      }
    ], 
    "keywords": [
      "cerebral venous thrombosis", 
      "main clinical features", 
      "internal jugular vein", 
      "blood flow velocity", 
      "phase-contrast magnetic resonance angiography", 
      "magnetic resonance angiography", 
      "phase-contrast MR angiography", 
      "collateral drainage", 
      "cerebral sinuses", 
      "imaging findings", 
      "clinical features", 
      "venous thrombosis", 
      "parenchymal abnormalities", 
      "cerebral veins", 
      "MRI characteristics", 
      "jugular vein", 
      "resonance angiography", 
      "MR angiography", 
      "acoustic window", 
      "PC MRA", 
      "angiography", 
      "patients", 
      "sinus", 
      "vein", 
      "diagnostic features", 
      "flow velocity", 
      "technical factors", 
      "thrombosis", 
      "abnormalities", 
      "manifestations", 
      "ultrasound", 
      "MRA", 
      "vessels", 
      "drainage", 
      "findings", 
      "assessment", 
      "skull", 
      "factors", 
      "data", 
      "common quality", 
      "features", 
      "reference data", 
      "purpose", 
      "ability", 
      "quality", 
      "visualization", 
      "characteristics", 
      "research", 
      "insights", 
      "window", 
      "velocity", 
      "estimation", 
      "velocity data", 
      "large cerebral sinuses"
    ], 
    "name": "Cerebral Venous Thrombosis: Diagnostic Features of Phase-Contrast MR Angiography", 
    "pagination": "551-560", 
    "productId": [
      {
        "name": "dimensions_id", 
        "type": "PropertyValue", 
        "value": [
          "pub.1048311755"
        ]
      }, 
      {
        "name": "doi", 
        "type": "PropertyValue", 
        "value": [
          "10.1007/s00723-011-0261-1"
        ]
      }
    ], 
    "sameAs": [
      "https://doi.org/10.1007/s00723-011-0261-1", 
      "https://app.dimensions.ai/details/publication/pub.1048311755"
    ], 
    "sdDataset": "articles", 
    "sdDatePublished": "2021-12-01T19:25", 
    "sdLicense": "https://scigraph.springernature.com/explorer/license/", 
    "sdPublisher": {
      "name": "Springer Nature - SN SciGraph project", 
      "type": "Organization"
    }, 
    "sdSource": "s3://com-springernature-scigraph/baseset/20211201/entities/gbq_results/article/article_545.jsonl", 
    "type": "ScholarlyArticle", 
    "url": "https://doi.org/10.1007/s00723-011-0261-1"
  }
]
 

Download the RDF metadata as:  json-ld nt turtle xml License info

HOW TO GET THIS DATA PROGRAMMATICALLY:

JSON-LD is a popular format for linked data which is fully compatible with JSON.

curl -H 'Accept: application/ld+json' 'https://scigraph.springernature.com/pub.10.1007/s00723-011-0261-1'

N-Triples is a line-based linked data format ideal for batch operations.

curl -H 'Accept: application/n-triples' 'https://scigraph.springernature.com/pub.10.1007/s00723-011-0261-1'

Turtle is a human-readable linked data format.

curl -H 'Accept: text/turtle' 'https://scigraph.springernature.com/pub.10.1007/s00723-011-0261-1'

RDF/XML is a standard XML format for linked data.

curl -H 'Accept: application/rdf+xml' 'https://scigraph.springernature.com/pub.10.1007/s00723-011-0261-1'


 

This table displays all metadata directly associated to this object as RDF triples.

148 TRIPLES      21 PREDICATES      82 URIs      71 LITERALS      6 BLANK NODES

Subject Predicate Object
1 sg:pub.10.1007/s00723-011-0261-1 schema:about anzsrc-for:02
2 anzsrc-for:0202
3 anzsrc-for:03
4 anzsrc-for:0301
5 anzsrc-for:0306
6 schema:author N9309d70f408e4f00b98c1a047cead878
7 schema:datePublished 2011-09-23
8 schema:datePublishedReg 2011-09-23
9 schema:description The estimation of blood flow velocity in cerebral veins and sinuses by ultrasound is limited because of technical factors that make visualization of the vessels near the acoustic windows of the skull difficult. The common quality of cerebral venous thrombosis (CVT) is associated with the poorly characterized imaging finding of parenchymal abnormalities. Phase-contrast magnetic resonance angiography (PC MRA) has offered some insight into these manifestations. The purpose of our research is to determine the ability of PC MRA to aid in the assessment of large cerebral sinuses and internal jugular veins, as well as to provide reference data for flow velocity in patients with CVT. We describe here the main clinical features and the MRI characteristics of collateral drainage and flow velocity data in patients with CVT.
10 schema:genre article
11 schema:inLanguage en
12 schema:isAccessibleForFree false
13 schema:isPartOf N627d2cccfcee42839cc89d8d65b6fdb9
14 N7e76e3457dd4418a9964ab05cbfdede6
15 sg:journal.1102112
16 schema:keywords MR angiography
17 MRA
18 MRI characteristics
19 PC MRA
20 ability
21 abnormalities
22 acoustic window
23 angiography
24 assessment
25 blood flow velocity
26 cerebral sinuses
27 cerebral veins
28 cerebral venous thrombosis
29 characteristics
30 clinical features
31 collateral drainage
32 common quality
33 data
34 diagnostic features
35 drainage
36 estimation
37 factors
38 features
39 findings
40 flow velocity
41 imaging findings
42 insights
43 internal jugular vein
44 jugular vein
45 large cerebral sinuses
46 magnetic resonance angiography
47 main clinical features
48 manifestations
49 parenchymal abnormalities
50 patients
51 phase-contrast MR angiography
52 phase-contrast magnetic resonance angiography
53 purpose
54 quality
55 reference data
56 research
57 resonance angiography
58 sinus
59 skull
60 technical factors
61 thrombosis
62 ultrasound
63 vein
64 velocity
65 velocity data
66 venous thrombosis
67 vessels
68 visualization
69 window
70 schema:name Cerebral Venous Thrombosis: Diagnostic Features of Phase-Contrast MR Angiography
71 schema:pagination 551-560
72 schema:productId N177e8ccbeede4c20bf6d6bc7eda3bf1f
73 Naa83938f60854b9b950a285abf0375b8
74 schema:sameAs https://app.dimensions.ai/details/publication/pub.1048311755
75 https://doi.org/10.1007/s00723-011-0261-1
76 schema:sdDatePublished 2021-12-01T19:25
77 schema:sdLicense https://scigraph.springernature.com/explorer/license/
78 schema:sdPublisher Nbbd63cb93f50459cade8e1f5ddec261e
79 schema:url https://doi.org/10.1007/s00723-011-0261-1
80 sgo:license sg:explorer/license/
81 sgo:sdDataset articles
82 rdf:type schema:ScholarlyArticle
83 N177e8ccbeede4c20bf6d6bc7eda3bf1f schema:name dimensions_id
84 schema:value pub.1048311755
85 rdf:type schema:PropertyValue
86 N22c37086f31d4bc1a2a2df54b0b45869 rdf:first sg:person.011154451231.04
87 rdf:rest N6f3bf02782934751897efef9ca361987
88 N305a16f821884435a1dfe0de7d9c0a04 rdf:first sg:person.015535314231.28
89 rdf:rest rdf:nil
90 N627d2cccfcee42839cc89d8d65b6fdb9 schema:volumeNumber 41
91 rdf:type schema:PublicationVolume
92 N6f3bf02782934751897efef9ca361987 rdf:first sg:person.0714612513.30
93 rdf:rest N305a16f821884435a1dfe0de7d9c0a04
94 N7e76e3457dd4418a9964ab05cbfdede6 schema:issueNumber 2-4
95 rdf:type schema:PublicationIssue
96 N9309d70f408e4f00b98c1a047cead878 rdf:first sg:person.01142753177.59
97 rdf:rest N22c37086f31d4bc1a2a2df54b0b45869
98 Naa83938f60854b9b950a285abf0375b8 schema:name doi
99 schema:value 10.1007/s00723-011-0261-1
100 rdf:type schema:PropertyValue
101 Nbbd63cb93f50459cade8e1f5ddec261e schema:name Springer Nature - SN SciGraph project
102 rdf:type schema:Organization
103 anzsrc-for:02 schema:inDefinedTermSet anzsrc-for:
104 schema:name Physical Sciences
105 rdf:type schema:DefinedTerm
106 anzsrc-for:0202 schema:inDefinedTermSet anzsrc-for:
107 schema:name Atomic, Molecular, Nuclear, Particle and Plasma Physics
108 rdf:type schema:DefinedTerm
109 anzsrc-for:03 schema:inDefinedTermSet anzsrc-for:
110 schema:name Chemical Sciences
111 rdf:type schema:DefinedTerm
112 anzsrc-for:0301 schema:inDefinedTermSet anzsrc-for:
113 schema:name Analytical Chemistry
114 rdf:type schema:DefinedTerm
115 anzsrc-for:0306 schema:inDefinedTermSet anzsrc-for:
116 schema:name Physical Chemistry (incl. Structural)
117 rdf:type schema:DefinedTerm
118 sg:journal.1102112 schema:issn 0937-9347
119 1613-7507
120 schema:name Applied Magnetic Resonance
121 schema:publisher Springer Nature
122 rdf:type schema:Periodical
123 sg:person.011154451231.04 schema:affiliation grid-institutes:grid.415877.8
124 schema:familyName Savelyeva
125 schema:givenName L. A.
126 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.011154451231.04
127 rdf:type schema:Person
128 sg:person.01142753177.59 schema:affiliation grid-institutes:grid.415877.8
129 schema:familyName Tulupov
130 schema:givenName A. A.
131 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01142753177.59
132 rdf:type schema:Person
133 sg:person.015535314231.28 schema:affiliation grid-institutes:grid.4605.7
134 schema:familyName Prygova
135 schema:givenName Yu. A.
136 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.015535314231.28
137 rdf:type schema:Person
138 sg:person.0714612513.30 schema:affiliation grid-institutes:grid.415877.8
139 schema:familyName Bogomyakova
140 schema:givenName O. B.
141 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0714612513.30
142 rdf:type schema:Person
143 grid-institutes:grid.415877.8 schema:alternateName “MRT Technologies” Department, Laboratory of Medical Diagnostic, International Tomography Center, Siberian Branch of the Russian Academy of Sciences, Institutskaya st. 3a, 630090, Novosibirsk, Russian Federation
144 schema:name “MRT Technologies” Department, Laboratory of Medical Diagnostic, International Tomography Center, Siberian Branch of the Russian Academy of Sciences, Institutskaya st. 3a, 630090, Novosibirsk, Russian Federation
145 rdf:type schema:Organization
146 grid-institutes:grid.4605.7 schema:alternateName Medicine Department, Novosibirsk State University, Pirogova st. 2, 630090, Novosibirsk, Russian Federation
147 schema:name Medicine Department, Novosibirsk State University, Pirogova st. 2, 630090, Novosibirsk, Russian Federation
148 rdf:type schema:Organization
 




Preview window. Press ESC to close (or click here)


...