Ontology type: schema:ScholarlyArticle
2016-02-05
AUTHORSShigenori Ito, Kanako Kinoshita, Akiko Endo, Masato Nakamura, Toshiya Muramatsu
ABSTRACTTo evaluate the feasibility of catheter down sizing for QCA, the reliability of a 4Fr catheter as a calibration device was evaluated. Repeated coronary angiograms of 9 lesions were obtained using 4Fr and 6Fr catheters under otherwise identical conditions. The calibration factor was measured 10 times by 4Fr and 6Fr catheters. QCA measurements including minimal lumen diameter (MLD), interpolated normal reference (Int N), percent diameter stenosis (%DS), and lesion length (LL) were performed by two technicians twice with a 3-month interval. The intraobserver and interobserver variability of each parameter was evaluated using intraclass correlation coefficients (ICCs). Mean of mean SD of calibration factor was significantly larger in 4Fr than in 6Fr in 9 lesions. The mean of mean coefficient of variance was significantly larger in 4Fr catheters vs in 6Fr catheters. A 6Fr catheter showed excellent reliability for both intraobserver and interobserver variability in MLD, Int N, %DS, and LL. In contrast, 4Fr showed that reliability in intraobserver variability depended on the analyst. Although reliability of interobserver variability in Int N measured by the 4Fr catheter was >0.80, the value was less than that by the 6Fr catheter. Taking these results into consideration, 4Fr catheters are less reliable than 6Fr catheters when measuring QCA data especially for follow-up data that need most accurate measurements of MLD and %DS. It would be better to use a 6Fr catheter to evaluate QCA measurements such as acute gain, late loss, restenosis rate, and device size. More... »
PAGES1752-1757
http://scigraph.springernature.com/pub.10.1007/s00380-016-0800-7
DOIhttp://dx.doi.org/10.1007/s00380-016-0800-7
DIMENSIONShttps://app.dimensions.ai/details/publication/pub.1037771511
PUBMEDhttps://www.ncbi.nlm.nih.gov/pubmed/26849831
JSON-LD is the canonical representation for SciGraph data.
TIP: You can open this SciGraph record using an external JSON-LD service: JSON-LD Playground Google SDTT
[
{
"@context": "https://springernature.github.io/scigraph/jsonld/sgcontext.json",
"about": [
{
"id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/11",
"inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/",
"name": "Medical and Health Sciences",
"type": "DefinedTerm"
},
{
"id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/1117",
"inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/",
"name": "Public Health and Health Services",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Aged",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Aged, 80 and over",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Cardiac Catheterization",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Cardiac Catheters",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Coronary Angiography",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Coronary Artery Disease",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Coronary Vessels",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Equipment Design",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Feasibility Studies",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Female",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Humans",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Male",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Middle Aged",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Observer Variation",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Predictive Value of Tests",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Reproducibility of Results",
"type": "DefinedTerm"
}
],
"author": [
{
"affiliation": {
"alternateName": "Division of Cardiology, Sankuro Hospital, 7-80, Kosaka-cho, 471-0035, Toyota, Japan",
"id": "http://www.grid.ac/institutes/None",
"name": [
"Division of Cardiology, Nagoya City East Medical Center, Nagoya, Japan",
"Japan Cardiovascular Imaging Core Laboratory, Tokyo, Japan",
"Division of Cardiology, Sankuro Hospital, 7-80, Kosaka-cho, 471-0035, Toyota, Japan"
],
"type": "Organization"
},
"familyName": "Ito",
"givenName": "Shigenori",
"id": "sg:person.01035612324.54",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01035612324.54"
],
"type": "Person"
},
{
"affiliation": {
"alternateName": "Japan Cardiovascular Imaging Core Laboratory, Tokyo, Japan",
"id": "http://www.grid.ac/institutes/None",
"name": [
"Japan Cardiovascular Imaging Core Laboratory, Tokyo, Japan"
],
"type": "Organization"
},
"familyName": "Kinoshita",
"givenName": "Kanako",
"type": "Person"
},
{
"affiliation": {
"alternateName": "Japan Cardiovascular Imaging Core Laboratory, Tokyo, Japan",
"id": "http://www.grid.ac/institutes/None",
"name": [
"Japan Cardiovascular Imaging Core Laboratory, Tokyo, Japan"
],
"type": "Organization"
},
"familyName": "Endo",
"givenName": "Akiko",
"type": "Person"
},
{
"affiliation": {
"alternateName": "Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, Tokyo, Japan",
"id": "http://www.grid.ac/institutes/grid.470115.6",
"name": [
"Japan Cardiovascular Imaging Core Laboratory, Tokyo, Japan",
"Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, Tokyo, Japan"
],
"type": "Organization"
},
"familyName": "Nakamura",
"givenName": "Masato",
"id": "sg:person.01031752616.54",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01031752616.54"
],
"type": "Person"
},
{
"affiliation": {
"alternateName": "Division of Cardiology, Tokyo General Hospital, Tokyo, Japan",
"id": "http://www.grid.ac/institutes/None",
"name": [
"Japan Cardiovascular Imaging Core Laboratory, Tokyo, Japan",
"Division of Cardiology, Tokyo General Hospital, Tokyo, Japan"
],
"type": "Organization"
},
"familyName": "Muramatsu",
"givenName": "Toshiya",
"id": "sg:person.01225552506.20",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01225552506.20"
],
"type": "Person"
}
],
"citation": [
{
"id": "sg:pub.10.1007/s00380-015-0636-6",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1000727102",
"https://doi.org/10.1007/s00380-015-0636-6"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/s00380-015-0640-x",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1010525743",
"https://doi.org/10.1007/s00380-015-0640-x"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/s00380-013-0382-6",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1007366485",
"https://doi.org/10.1007/s00380-013-0382-6"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/s00380-014-0492-9",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1030420850",
"https://doi.org/10.1007/s00380-014-0492-9"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/s00380-013-0327-0",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1046011598",
"https://doi.org/10.1007/s00380-013-0327-0"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/bf01137536",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1049023745",
"https://doi.org/10.1007/bf01137536"
],
"type": "CreativeWork"
}
],
"datePublished": "2016-02-05",
"datePublishedReg": "2016-02-05",
"description": "To evaluate the feasibility of catheter down sizing for QCA, the reliability of a 4Fr catheter as a calibration device was evaluated. Repeated coronary angiograms of 9 lesions were obtained using 4Fr and 6Fr catheters under otherwise identical conditions. The calibration factor was measured 10 times by 4Fr and 6Fr catheters. QCA measurements including minimal lumen diameter (MLD), interpolated normal reference (Int N), percent diameter stenosis (%DS), and lesion length (LL) were performed by two technicians twice with a 3-month interval. The intraobserver and interobserver variability of each parameter was evaluated using intraclass correlation coefficients (ICCs). Mean of mean SD of calibration factor was significantly larger in 4Fr than in 6Fr in 9 lesions. The mean of mean coefficient of variance was significantly larger in 4Fr catheters vs in 6Fr catheters. A 6Fr catheter showed excellent reliability for both intraobserver and interobserver variability in MLD, Int N, %DS, and LL. In contrast, 4Fr showed that reliability in intraobserver variability depended on the analyst. Although reliability of interobserver variability in Int N measured by the 4Fr catheter was\u00a0>0.80, the value was less than that by the 6Fr catheter. Taking these results into consideration, 4Fr catheters are less reliable than 6Fr catheters when measuring QCA data especially for follow-up data that need most accurate measurements of MLD and %DS. It would be better to use a 6Fr catheter to evaluate QCA measurements such as acute gain, late loss, restenosis rate, and device size.",
"genre": "article",
"id": "sg:pub.10.1007/s00380-016-0800-7",
"inLanguage": "en",
"isAccessibleForFree": false,
"isPartOf": [
{
"id": "sg:journal.1095887",
"issn": [
"0910-8327",
"1615-2573"
],
"name": "Heart and Vessels",
"publisher": "Springer Nature",
"type": "Periodical"
},
{
"issueNumber": "11",
"type": "PublicationIssue"
},
{
"type": "PublicationVolume",
"volumeNumber": "31"
}
],
"keywords": [
"minimal lumen diameter",
"intraclass correlation coefficient",
"lesion length",
"interobserver variability",
"QCA measurements",
"quantitative coronary angiographic measurements",
"percent diameter stenosis",
"restenosis rate",
"acute gain",
"coronary angiogram",
"diameter stenosis",
"late loss",
"catheter",
"catheter size",
"lumen diameter",
"angiographic measurements",
"normal reference",
"QCA data",
"intraobserver variability",
"mean SD",
"lesions",
"excellent reliability",
"stenosis",
"angiograms",
"mean coefficient",
"intraobserver",
"correlation coefficient",
"factors",
"SD",
"DS",
"intervals",
"variability",
"data",
"technicians",
"contrast",
"rate",
"loss",
"identical conditions",
"reliability",
"measurements",
"feasibility",
"time",
"size",
"impact",
"accurate measurement",
"gain",
"diameter",
"length",
"results",
"variance",
"calibration factor",
"values",
"means",
"consideration",
"conditions",
"reference",
"device size",
"QCA",
"parameters",
"devices",
"coefficient",
"sizing",
"calibration device",
"analysts"
],
"name": "Impact of catheter size on reliability of quantitative coronary angiographic measurements (comparison of 4Fr and 6Fr catheters)",
"pagination": "1752-1757",
"productId": [
{
"name": "dimensions_id",
"type": "PropertyValue",
"value": [
"pub.1037771511"
]
},
{
"name": "doi",
"type": "PropertyValue",
"value": [
"10.1007/s00380-016-0800-7"
]
},
{
"name": "pubmed_id",
"type": "PropertyValue",
"value": [
"26849831"
]
}
],
"sameAs": [
"https://doi.org/10.1007/s00380-016-0800-7",
"https://app.dimensions.ai/details/publication/pub.1037771511"
],
"sdDataset": "articles",
"sdDatePublished": "2022-06-01T22:16",
"sdLicense": "https://scigraph.springernature.com/explorer/license/",
"sdPublisher": {
"name": "Springer Nature - SN SciGraph project",
"type": "Organization"
},
"sdSource": "s3://com-springernature-scigraph/baseset/20220601/entities/gbq_results/article/article_696.jsonl",
"type": "ScholarlyArticle",
"url": "https://doi.org/10.1007/s00380-016-0800-7"
}
]
Download the RDF metadata as:Â json-ld nt turtle xml License info
JSON-LD is a popular format for linked data which is fully compatible with JSON.
curl -H 'Accept: application/ld+json' 'https://scigraph.springernature.com/pub.10.1007/s00380-016-0800-7'
N-Triples is a line-based linked data format ideal for batch operations.
curl -H 'Accept: application/n-triples' 'https://scigraph.springernature.com/pub.10.1007/s00380-016-0800-7'
Turtle is a human-readable linked data format.
curl -H 'Accept: text/turtle' 'https://scigraph.springernature.com/pub.10.1007/s00380-016-0800-7'
RDF/XML is a standard XML format for linked data.
curl -H 'Accept: application/rdf+xml' 'https://scigraph.springernature.com/pub.10.1007/s00380-016-0800-7'
This table displays all metadata directly associated to this object as RDF triples.
249 TRIPLES
22 PREDICATES
112 URIs
98 LITERALS
23 BLANK NODES