Radiological profile of anemia on unenhanced MDCT of the thorax View Full Text


Ontology type: schema:ScholarlyArticle      Open Access: True


Article Info

DATE

2008-04-02

AUTHORS

Ehab M. Kamel, Elena Rizzo, Michel A. Duchosal, Rafael Duran, Vasco Goncalves-Matoso, Pierre Schnyder, Salah D. Qanadli

ABSTRACT

Our aim was to investigate the diagnostic value of unenhanced MDCT in anemic patients. Fifty consecutive patients with proven anemia and 50 nonanemic matched group for age, sex and body mass index were evaluated. In either group, hemoglobin levels were assessed no more than 24 h from an unenhanced CT of the thorax. For each patient, the presence of a hyperattenuating aortic wall (aortic ring sign) and/or dense interventricular septum (subjective parameters) were identified by two radiologists who were blinded to the laboratory findings. Furthermore, the aortic CT attenuation values (objective parameter) were also obtained and correlated with the hemoglobin levels. The sensitivity and specificity in detecting anemia were calculated for each variable, and ROC analysis was generated for subjective and objective parameters. Subjective image analysis revealed that the aortic ring sign was more sensitive than the interventricular septum sign for anemia detection (84% vs. 72%), whereas this latter sign was more specific (100% vs. 92%). A good correlation (r = 0.60) was observed between the aortic CT attenuation values and the hemoglobin levels in the whole study population. Using a threshold of ≤35 HU for anemia diagnosis, the sensitivity and specificity of aortic CT attenuation value were 84% and 94%, respectively, with the largest area under the curve (0.89) among all diagnostic criteria. However, the best trade-off between sensitivity (80%) and specificity (100%) was obtained from combining both subjective and objective analysis. Interpreting anemia upon unnenhanced MDCT of the thorax is quite feasible. A diagnostic approach that considers both subjective and objective analysis offers the best trade-off between sensitivity and specificity. More... »

PAGES

1863-1868

Identifiers

URI

http://scigraph.springernature.com/pub.10.1007/s00330-008-0950-9

DOI

http://dx.doi.org/10.1007/s00330-008-0950-9

DIMENSIONS

https://app.dimensions.ai/details/publication/pub.1010750041

PUBMED

https://www.ncbi.nlm.nih.gov/pubmed/18386013


Indexing Status Check whether this publication has been indexed by Scopus and Web Of Science using the SN Indexing Status Tool
Incoming Citations Browse incoming citations for this publication using opencitations.net

JSON-LD is the canonical representation for SciGraph data.

TIP: You can open this SciGraph record using an external JSON-LD service: JSON-LD Playground Google SDTT

[
  {
    "@context": "https://springernature.github.io/scigraph/jsonld/sgcontext.json", 
    "about": [
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/11", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "name": "Medical and Health Sciences", 
        "type": "DefinedTerm"
      }, 
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/1102", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "name": "Cardiorespiratory Medicine and Haematology", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Adult", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Aged", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Aged, 80 and over", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Anemia", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Aortography", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Contrast Media", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Female", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Heart Septum", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Humans", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Male", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Middle Aged", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Radiography, Thoracic", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Reproducibility of Results", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Sensitivity and Specificity", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Single-Blind Method", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Tomography, X-Ray Computed", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Young Adult", 
        "type": "DefinedTerm"
      }
    ], 
    "author": [
      {
        "affiliation": {
          "alternateName": "Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011, Lausanne, Switzerland", 
          "id": "http://www.grid.ac/institutes/grid.8515.9", 
          "name": [
            "Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011, Lausanne, Switzerland"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Kamel", 
        "givenName": "Ehab M.", 
        "id": "sg:person.01243757067.93", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01243757067.93"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011, Lausanne, Switzerland", 
          "id": "http://www.grid.ac/institutes/grid.8515.9", 
          "name": [
            "Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011, Lausanne, Switzerland"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Rizzo", 
        "givenName": "Elena", 
        "id": "sg:person.0607152020.54", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0607152020.54"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Service of Hematology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011, Lausanne, Switzerland", 
          "id": "http://www.grid.ac/institutes/grid.8515.9", 
          "name": [
            "Service of Hematology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011, Lausanne, Switzerland"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Duchosal", 
        "givenName": "Michel A.", 
        "id": "sg:person.01330423271.79", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01330423271.79"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011, Lausanne, Switzerland", 
          "id": "http://www.grid.ac/institutes/grid.8515.9", 
          "name": [
            "Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011, Lausanne, Switzerland"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Duran", 
        "givenName": "Rafael", 
        "id": "sg:person.0637123242.50", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0637123242.50"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011, Lausanne, Switzerland", 
          "id": "http://www.grid.ac/institutes/grid.8515.9", 
          "name": [
            "Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011, Lausanne, Switzerland"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Goncalves-Matoso", 
        "givenName": "Vasco", 
        "id": "sg:person.01300365437.22", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01300365437.22"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011, Lausanne, Switzerland", 
          "id": "http://www.grid.ac/institutes/grid.8515.9", 
          "name": [
            "Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011, Lausanne, Switzerland"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Schnyder", 
        "givenName": "Pierre", 
        "id": "sg:person.01305400010.47", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01305400010.47"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Diagnostic and Interventional Radiology, University of Lausanne-CHUV, 1011, Lausanne, Switzerland", 
          "id": "http://www.grid.ac/institutes/grid.9851.5", 
          "name": [
            "Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011, Lausanne, Switzerland", 
            "Diagnostic and Interventional Radiology, University of Lausanne-CHUV, 1011, Lausanne, Switzerland"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Qanadli", 
        "givenName": "Salah D.", 
        "id": "sg:person.0665540063.53", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0665540063.53"
        ], 
        "type": "Person"
      }
    ], 
    "citation": [
      {
        "id": "sg:pub.10.1007/s00330-006-0532-7", 
        "sameAs": [
          "https://app.dimensions.ai/details/publication/pub.1005308343", 
          "https://doi.org/10.1007/s00330-006-0532-7"
        ], 
        "type": "CreativeWork"
      }, 
      {
        "id": "sg:pub.10.1007/s00330-007-0677-z", 
        "sameAs": [
          "https://app.dimensions.ai/details/publication/pub.1050109028", 
          "https://doi.org/10.1007/s00330-007-0677-z"
        ], 
        "type": "CreativeWork"
      }, 
      {
        "id": "sg:pub.10.1007/s00330-006-0565-y", 
        "sameAs": [
          "https://app.dimensions.ai/details/publication/pub.1027412514", 
          "https://doi.org/10.1007/s00330-006-0565-y"
        ], 
        "type": "CreativeWork"
      }
    ], 
    "datePublished": "2008-04-02", 
    "datePublishedReg": "2008-04-02", 
    "description": "Our aim was to investigate the diagnostic value of unenhanced MDCT in anemic patients. Fifty consecutive patients with proven anemia and 50 nonanemic matched group for age, sex and body mass index were evaluated. In either group, hemoglobin levels were assessed no more than 24\u00a0h from an unenhanced CT of the thorax. For each patient, the presence of a hyperattenuating aortic wall (aortic ring sign) and/or dense interventricular septum (subjective parameters) were identified by two radiologists who were blinded to the laboratory findings. Furthermore, the aortic CT attenuation values (objective parameter) were also obtained and correlated with the hemoglobin levels. The sensitivity and specificity in detecting anemia were calculated for each variable, and ROC analysis was generated for subjective and objective parameters. Subjective image analysis revealed that the aortic ring sign was more sensitive than the interventricular septum sign for anemia detection (84% vs. 72%), whereas this latter sign was more specific (100% vs. 92%). A good correlation (r\u2009=\u20090.60) was observed between the aortic CT attenuation values and the hemoglobin levels in the whole study population. Using a threshold of \u226435\u00a0HU for anemia diagnosis, the sensitivity and specificity of aortic CT attenuation value were 84% and 94%, respectively, with the largest area under the curve (0.89) among all diagnostic criteria. However, the best trade-off between sensitivity (80%) and specificity (100%) was obtained from combining both subjective and objective analysis. Interpreting anemia upon unnenhanced MDCT of the thorax is quite feasible. A diagnostic approach that considers both subjective and objective analysis offers the best trade-off between sensitivity and specificity.", 
    "genre": "article", 
    "id": "sg:pub.10.1007/s00330-008-0950-9", 
    "isAccessibleForFree": true, 
    "isPartOf": [
      {
        "id": "sg:journal.1289120", 
        "issn": [
          "0938-7994", 
          "1432-1084"
        ], 
        "name": "European Radiology", 
        "publisher": "Springer Nature", 
        "type": "Periodical"
      }, 
      {
        "issueNumber": "9", 
        "type": "PublicationIssue"
      }, 
      {
        "type": "PublicationVolume", 
        "volumeNumber": "18"
      }
    ], 
    "keywords": [
      "CT attenuation values", 
      "hemoglobin levels", 
      "unenhanced MDCT", 
      "body mass index", 
      "whole study population", 
      "attenuation values", 
      "consecutive patients", 
      "radiological profile", 
      "anemic patients", 
      "mass index", 
      "laboratory findings", 
      "interventricular septum", 
      "unenhanced CT", 
      "study population", 
      "diagnostic criteria", 
      "aortic wall", 
      "diagnostic value", 
      "ring sign", 
      "anemia", 
      "patients", 
      "ROC analysis", 
      "latter sign", 
      "anemia diagnosis", 
      "diagnostic approach", 
      "MDCT", 
      "anemia detection", 
      "objective parameters", 
      "thorax", 
      "subjective image analysis", 
      "signs", 
      "specificity", 
      "group", 
      "levels", 
      "diagnosis", 
      "CT", 
      "sensitivity", 
      "septum", 
      "age", 
      "sex", 
      "radiologists", 
      "good correlation", 
      "objective analysis", 
      "aim", 
      "population", 
      "findings", 
      "index", 
      "analysis", 
      "HU", 
      "criteria", 
      "image analysis", 
      "correlation", 
      "values", 
      "presence", 
      "profile", 
      "threshold", 
      "wall", 
      "variables", 
      "detection", 
      "curves", 
      "area", 
      "approach", 
      "parameters", 
      "large areas"
    ], 
    "name": "Radiological profile of anemia on unenhanced MDCT of the thorax", 
    "pagination": "1863-1868", 
    "productId": [
      {
        "name": "dimensions_id", 
        "type": "PropertyValue", 
        "value": [
          "pub.1010750041"
        ]
      }, 
      {
        "name": "doi", 
        "type": "PropertyValue", 
        "value": [
          "10.1007/s00330-008-0950-9"
        ]
      }, 
      {
        "name": "pubmed_id", 
        "type": "PropertyValue", 
        "value": [
          "18386013"
        ]
      }
    ], 
    "sameAs": [
      "https://doi.org/10.1007/s00330-008-0950-9", 
      "https://app.dimensions.ai/details/publication/pub.1010750041"
    ], 
    "sdDataset": "articles", 
    "sdDatePublished": "2022-10-01T06:34", 
    "sdLicense": "https://scigraph.springernature.com/explorer/license/", 
    "sdPublisher": {
      "name": "Springer Nature - SN SciGraph project", 
      "type": "Organization"
    }, 
    "sdSource": "s3://com-springernature-scigraph/baseset/20221001/entities/gbq_results/article/article_463.jsonl", 
    "type": "ScholarlyArticle", 
    "url": "https://doi.org/10.1007/s00330-008-0950-9"
  }
]
 

Download the RDF metadata as:  json-ld nt turtle xml License info

HOW TO GET THIS DATA PROGRAMMATICALLY:

JSON-LD is a popular format for linked data which is fully compatible with JSON.

curl -H 'Accept: application/ld+json' 'https://scigraph.springernature.com/pub.10.1007/s00330-008-0950-9'

N-Triples is a line-based linked data format ideal for batch operations.

curl -H 'Accept: application/n-triples' 'https://scigraph.springernature.com/pub.10.1007/s00330-008-0950-9'

Turtle is a human-readable linked data format.

curl -H 'Accept: text/turtle' 'https://scigraph.springernature.com/pub.10.1007/s00330-008-0950-9'

RDF/XML is a standard XML format for linked data.

curl -H 'Accept: application/rdf+xml' 'https://scigraph.springernature.com/pub.10.1007/s00330-008-0950-9'


 

This table displays all metadata directly associated to this object as RDF triples.

252 TRIPLES      21 PREDICATES      108 URIs      97 LITERALS      24 BLANK NODES

Subject Predicate Object
1 sg:pub.10.1007/s00330-008-0950-9 schema:about N16012ebaf56d4d58bae2a6c1f6f3d7d5
2 N2e3f8d4ccf344ddaa19a77a65eb52cdf
3 N475dbcedfea14821b5eed012b0744629
4 N4a5c9d69d3774fd7951f63ec5fca8453
5 N4a61506f738d4959b3c7153b6c77f6b8
6 N54ba787ead4d49e7abdd8bc6d2aa5e3b
7 N66a9a62c023e409eab6088f217c288f8
8 N680311ea46194245942f408285fd801e
9 N897a72c0abb24d87aa0536edec291f73
10 N8eef8639ae30455a8d53764fb01e5697
11 Na82e69e40ace486abfc5a6c8a083ea23
12 Nb7a72df661d849f68dab8f88de0a92bd
13 Nb8a1c5795cdb4097acfb89fc0f7b2360
14 Nbf83b077f5dc4b69aa43b89a0a081c0c
15 Nd49120c430244f30bf9b9e511224bcac
16 Ne127a952d5004b7bb7013920773e1e4f
17 Nf85fe4ffa4ee4330b9593b3ad4212c38
18 anzsrc-for:11
19 anzsrc-for:1102
20 schema:author Nf122abcf9be04a73829993afb9bb7c86
21 schema:citation sg:pub.10.1007/s00330-006-0532-7
22 sg:pub.10.1007/s00330-006-0565-y
23 sg:pub.10.1007/s00330-007-0677-z
24 schema:datePublished 2008-04-02
25 schema:datePublishedReg 2008-04-02
26 schema:description Our aim was to investigate the diagnostic value of unenhanced MDCT in anemic patients. Fifty consecutive patients with proven anemia and 50 nonanemic matched group for age, sex and body mass index were evaluated. In either group, hemoglobin levels were assessed no more than 24 h from an unenhanced CT of the thorax. For each patient, the presence of a hyperattenuating aortic wall (aortic ring sign) and/or dense interventricular septum (subjective parameters) were identified by two radiologists who were blinded to the laboratory findings. Furthermore, the aortic CT attenuation values (objective parameter) were also obtained and correlated with the hemoglobin levels. The sensitivity and specificity in detecting anemia were calculated for each variable, and ROC analysis was generated for subjective and objective parameters. Subjective image analysis revealed that the aortic ring sign was more sensitive than the interventricular septum sign for anemia detection (84% vs. 72%), whereas this latter sign was more specific (100% vs. 92%). A good correlation (r = 0.60) was observed between the aortic CT attenuation values and the hemoglobin levels in the whole study population. Using a threshold of ≤35 HU for anemia diagnosis, the sensitivity and specificity of aortic CT attenuation value were 84% and 94%, respectively, with the largest area under the curve (0.89) among all diagnostic criteria. However, the best trade-off between sensitivity (80%) and specificity (100%) was obtained from combining both subjective and objective analysis. Interpreting anemia upon unnenhanced MDCT of the thorax is quite feasible. A diagnostic approach that considers both subjective and objective analysis offers the best trade-off between sensitivity and specificity.
27 schema:genre article
28 schema:isAccessibleForFree true
29 schema:isPartOf N1e57e522c2984f9493d660c95b9dbdb4
30 N354e9feac0624d83bf2744bc6425741d
31 sg:journal.1289120
32 schema:keywords CT
33 CT attenuation values
34 HU
35 MDCT
36 ROC analysis
37 age
38 aim
39 analysis
40 anemia
41 anemia detection
42 anemia diagnosis
43 anemic patients
44 aortic wall
45 approach
46 area
47 attenuation values
48 body mass index
49 consecutive patients
50 correlation
51 criteria
52 curves
53 detection
54 diagnosis
55 diagnostic approach
56 diagnostic criteria
57 diagnostic value
58 findings
59 good correlation
60 group
61 hemoglobin levels
62 image analysis
63 index
64 interventricular septum
65 laboratory findings
66 large areas
67 latter sign
68 levels
69 mass index
70 objective analysis
71 objective parameters
72 parameters
73 patients
74 population
75 presence
76 profile
77 radiological profile
78 radiologists
79 ring sign
80 sensitivity
81 septum
82 sex
83 signs
84 specificity
85 study population
86 subjective image analysis
87 thorax
88 threshold
89 unenhanced CT
90 unenhanced MDCT
91 values
92 variables
93 wall
94 whole study population
95 schema:name Radiological profile of anemia on unenhanced MDCT of the thorax
96 schema:pagination 1863-1868
97 schema:productId N461955d4e3de46e484255da8a595138c
98 N652c8484e5f043fd97f2a9a864c091c6
99 Nd6a20e58930d418ca82a82e5cb5cca91
100 schema:sameAs https://app.dimensions.ai/details/publication/pub.1010750041
101 https://doi.org/10.1007/s00330-008-0950-9
102 schema:sdDatePublished 2022-10-01T06:34
103 schema:sdLicense https://scigraph.springernature.com/explorer/license/
104 schema:sdPublisher Na89778d795044c288a7dba4dc6eb971e
105 schema:url https://doi.org/10.1007/s00330-008-0950-9
106 sgo:license sg:explorer/license/
107 sgo:sdDataset articles
108 rdf:type schema:ScholarlyArticle
109 N16012ebaf56d4d58bae2a6c1f6f3d7d5 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
110 schema:name Aged
111 rdf:type schema:DefinedTerm
112 N1e57e522c2984f9493d660c95b9dbdb4 schema:issueNumber 9
113 rdf:type schema:PublicationIssue
114 N2e3f8d4ccf344ddaa19a77a65eb52cdf schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
115 schema:name Reproducibility of Results
116 rdf:type schema:DefinedTerm
117 N354e9feac0624d83bf2744bc6425741d schema:volumeNumber 18
118 rdf:type schema:PublicationVolume
119 N461955d4e3de46e484255da8a595138c schema:name pubmed_id
120 schema:value 18386013
121 rdf:type schema:PropertyValue
122 N475dbcedfea14821b5eed012b0744629 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
123 schema:name Female
124 rdf:type schema:DefinedTerm
125 N4a5c9d69d3774fd7951f63ec5fca8453 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
126 schema:name Radiography, Thoracic
127 rdf:type schema:DefinedTerm
128 N4a61506f738d4959b3c7153b6c77f6b8 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
129 schema:name Aged, 80 and over
130 rdf:type schema:DefinedTerm
131 N539f78bb42004755ad57f26babf8d2b7 rdf:first sg:person.0607152020.54
132 rdf:rest Nf9c7d519c93e4107ae6e7f0bb2494ba2
133 N54ba787ead4d49e7abdd8bc6d2aa5e3b schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
134 schema:name Male
135 rdf:type schema:DefinedTerm
136 N652c8484e5f043fd97f2a9a864c091c6 schema:name dimensions_id
137 schema:value pub.1010750041
138 rdf:type schema:PropertyValue
139 N66a9a62c023e409eab6088f217c288f8 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
140 schema:name Heart Septum
141 rdf:type schema:DefinedTerm
142 N680311ea46194245942f408285fd801e schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
143 schema:name Young Adult
144 rdf:type schema:DefinedTerm
145 N8639c9fe63834e2f95ed0c9e95abb3d4 rdf:first sg:person.01300365437.22
146 rdf:rest N9fe62e31aa5a4fa39759c4eb0c48f9ce
147 N897a72c0abb24d87aa0536edec291f73 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
148 schema:name Tomography, X-Ray Computed
149 rdf:type schema:DefinedTerm
150 N8eef8639ae30455a8d53764fb01e5697 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
151 schema:name Adult
152 rdf:type schema:DefinedTerm
153 N9fe62e31aa5a4fa39759c4eb0c48f9ce rdf:first sg:person.01305400010.47
154 rdf:rest Nb5b9b4269a5a41b88462ea85a83ad905
155 Na7746ecc2b494ef89aec1ff159a57a0e rdf:first sg:person.0637123242.50
156 rdf:rest N8639c9fe63834e2f95ed0c9e95abb3d4
157 Na82e69e40ace486abfc5a6c8a083ea23 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
158 schema:name Single-Blind Method
159 rdf:type schema:DefinedTerm
160 Na89778d795044c288a7dba4dc6eb971e schema:name Springer Nature - SN SciGraph project
161 rdf:type schema:Organization
162 Nb5b9b4269a5a41b88462ea85a83ad905 rdf:first sg:person.0665540063.53
163 rdf:rest rdf:nil
164 Nb7a72df661d849f68dab8f88de0a92bd schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
165 schema:name Contrast Media
166 rdf:type schema:DefinedTerm
167 Nb8a1c5795cdb4097acfb89fc0f7b2360 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
168 schema:name Anemia
169 rdf:type schema:DefinedTerm
170 Nbf83b077f5dc4b69aa43b89a0a081c0c schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
171 schema:name Humans
172 rdf:type schema:DefinedTerm
173 Nd49120c430244f30bf9b9e511224bcac schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
174 schema:name Aortography
175 rdf:type schema:DefinedTerm
176 Nd6a20e58930d418ca82a82e5cb5cca91 schema:name doi
177 schema:value 10.1007/s00330-008-0950-9
178 rdf:type schema:PropertyValue
179 Ne127a952d5004b7bb7013920773e1e4f schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
180 schema:name Middle Aged
181 rdf:type schema:DefinedTerm
182 Nf122abcf9be04a73829993afb9bb7c86 rdf:first sg:person.01243757067.93
183 rdf:rest N539f78bb42004755ad57f26babf8d2b7
184 Nf85fe4ffa4ee4330b9593b3ad4212c38 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
185 schema:name Sensitivity and Specificity
186 rdf:type schema:DefinedTerm
187 Nf9c7d519c93e4107ae6e7f0bb2494ba2 rdf:first sg:person.01330423271.79
188 rdf:rest Na7746ecc2b494ef89aec1ff159a57a0e
189 anzsrc-for:11 schema:inDefinedTermSet anzsrc-for:
190 schema:name Medical and Health Sciences
191 rdf:type schema:DefinedTerm
192 anzsrc-for:1102 schema:inDefinedTermSet anzsrc-for:
193 schema:name Cardiorespiratory Medicine and Haematology
194 rdf:type schema:DefinedTerm
195 sg:journal.1289120 schema:issn 0938-7994
196 1432-1084
197 schema:name European Radiology
198 schema:publisher Springer Nature
199 rdf:type schema:Periodical
200 sg:person.01243757067.93 schema:affiliation grid-institutes:grid.8515.9
201 schema:familyName Kamel
202 schema:givenName Ehab M.
203 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01243757067.93
204 rdf:type schema:Person
205 sg:person.01300365437.22 schema:affiliation grid-institutes:grid.8515.9
206 schema:familyName Goncalves-Matoso
207 schema:givenName Vasco
208 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01300365437.22
209 rdf:type schema:Person
210 sg:person.01305400010.47 schema:affiliation grid-institutes:grid.8515.9
211 schema:familyName Schnyder
212 schema:givenName Pierre
213 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01305400010.47
214 rdf:type schema:Person
215 sg:person.01330423271.79 schema:affiliation grid-institutes:grid.8515.9
216 schema:familyName Duchosal
217 schema:givenName Michel A.
218 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01330423271.79
219 rdf:type schema:Person
220 sg:person.0607152020.54 schema:affiliation grid-institutes:grid.8515.9
221 schema:familyName Rizzo
222 schema:givenName Elena
223 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0607152020.54
224 rdf:type schema:Person
225 sg:person.0637123242.50 schema:affiliation grid-institutes:grid.8515.9
226 schema:familyName Duran
227 schema:givenName Rafael
228 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0637123242.50
229 rdf:type schema:Person
230 sg:person.0665540063.53 schema:affiliation grid-institutes:grid.9851.5
231 schema:familyName Qanadli
232 schema:givenName Salah D.
233 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0665540063.53
234 rdf:type schema:Person
235 sg:pub.10.1007/s00330-006-0532-7 schema:sameAs https://app.dimensions.ai/details/publication/pub.1005308343
236 https://doi.org/10.1007/s00330-006-0532-7
237 rdf:type schema:CreativeWork
238 sg:pub.10.1007/s00330-006-0565-y schema:sameAs https://app.dimensions.ai/details/publication/pub.1027412514
239 https://doi.org/10.1007/s00330-006-0565-y
240 rdf:type schema:CreativeWork
241 sg:pub.10.1007/s00330-007-0677-z schema:sameAs https://app.dimensions.ai/details/publication/pub.1050109028
242 https://doi.org/10.1007/s00330-007-0677-z
243 rdf:type schema:CreativeWork
244 grid-institutes:grid.8515.9 schema:alternateName Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011, Lausanne, Switzerland
245 Service of Hematology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011, Lausanne, Switzerland
246 schema:name Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011, Lausanne, Switzerland
247 Service of Hematology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011, Lausanne, Switzerland
248 rdf:type schema:Organization
249 grid-institutes:grid.9851.5 schema:alternateName Diagnostic and Interventional Radiology, University of Lausanne-CHUV, 1011, Lausanne, Switzerland
250 schema:name Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (CHUV), 1011, Lausanne, Switzerland
251 Diagnostic and Interventional Radiology, University of Lausanne-CHUV, 1011, Lausanne, Switzerland
252 rdf:type schema:Organization
 




Preview window. Press ESC to close (or click here)


...