Ontology type: schema:ScholarlyArticle
1997-11
AUTHORSJens J. Froelich, Martin Hoppe, Christoph Nahrstedt, Klemens H. Barth, H. Joachim Wagner, Klaus J. Klose
ABSTRACTPURPOSE: Luminal diameters measured in vivo by calibrated-catheter angiography and by intravascular ultrasound were correlated with those obtained from pressure-fixed histologic cross-sections to determine the accuracy of both methods. METHODS: Angiographic and endosonographic diameter measurements were performed in the center of stents placed in the iliac arteries of 10 miniature pigs and were compared with luminal and stent diameters in postmortem, pressure-fixed, histologic cross-sections from identical locations. RESULTS: Compared with histologic diameters, magnification-corrected angiographic measurements still magnified vascular luminal diameters by 0.7 +/- 0.71 mm (r = 0.41, Pearson; p < 0.003, Wilcoxon, matched pairs), whereas intravascular ultrasound measurements proved to be almost identical to the histologic lumina (r = 0.95, Pearson; p > 0. 5, Wilcoxon, matched pairs). Similarly, stent diameters correlated well between endosonographic and histologic measurements (r = 0.91; p = 0.002), and less well between angiographic and histologic diameters (r = 0.62; p = 0.002). CONCLUSION: Since calibrated angiography still overestimates vascular lumina, endosonography is the preferred technique for accurate in vivo measurements. More... »
PAGES452-456
http://scigraph.springernature.com/pub.10.1007/s002709900192
DOIhttp://dx.doi.org/10.1007/s002709900192
DIMENSIONShttps://app.dimensions.ai/details/publication/pub.1052540857
PUBMEDhttps://www.ncbi.nlm.nih.gov/pubmed/9354715
JSON-LD is the canonical representation for SciGraph data.
TIP: You can open this SciGraph record using an external JSON-LD service: JSON-LD Playground Google SDTT
[
{
"@context": "https://springernature.github.io/scigraph/jsonld/sgcontext.json",
"about": [
{
"id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/1102",
"inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/",
"name": "Cardiorespiratory Medicine and Haematology",
"type": "DefinedTerm"
},
{
"id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/11",
"inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/",
"name": "Medical and Health Sciences",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Angiography",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Animals",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Arteries",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Calibration",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Endosonography",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Iliac Artery",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Reference Values",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Stents",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Swine",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Swine, Miniature",
"type": "DefinedTerm"
}
],
"author": [
{
"affiliation": {
"alternateName": "Universit\u00e4tsklinikum Gie\u00dfen und Marburg",
"id": "https://www.grid.ac/institutes/grid.411067.5",
"name": [
"Medizinisches Zentrum f\u00fcr Radiologie, Abteilung f\u00fcr Strahlendiagnostik, Klinikum der Philipps-Universit\u00e4t, Baldingerstrasse, D-35043 Marburg, Germany, DE"
],
"type": "Organization"
},
"familyName": "Froelich",
"givenName": "Jens J.",
"id": "sg:person.0761131251.83",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0761131251.83"
],
"type": "Person"
},
{
"affiliation": {
"alternateName": "Universit\u00e4tsklinikum Gie\u00dfen und Marburg",
"id": "https://www.grid.ac/institutes/grid.411067.5",
"name": [
"Medizinisches Zentrum f\u00fcr Radiologie, Abteilung f\u00fcr Strahlendiagnostik, Klinikum der Philipps-Universit\u00e4t, Baldingerstrasse, D-35043 Marburg, Germany, DE"
],
"type": "Organization"
},
"familyName": "Hoppe",
"givenName": "Martin",
"id": "sg:person.0627601303.72",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0627601303.72"
],
"type": "Person"
},
{
"affiliation": {
"alternateName": "Universit\u00e4tsklinikum Gie\u00dfen und Marburg",
"id": "https://www.grid.ac/institutes/grid.411067.5",
"name": [
"Medizinisches Zentrum f\u00fcr Radiologie, Abteilung f\u00fcr Strahlendiagnostik, Klinikum der Philipps-Universit\u00e4t, Baldingerstrasse, D-35043 Marburg, Germany, DE"
],
"type": "Organization"
},
"familyName": "Nahrstedt",
"givenName": "Christoph",
"type": "Person"
},
{
"affiliation": {
"alternateName": "MedStar Georgetown University Hospital",
"id": "https://www.grid.ac/institutes/grid.411663.7",
"name": [
"Division of Vascular and Interventional Radiology, Georgetown University Hospital, 3800 Reservoir Road, N.W., Washington, DC 20007, USA, US"
],
"type": "Organization"
},
"familyName": "Barth",
"givenName": "Klemens H.",
"id": "sg:person.01232414122.64",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01232414122.64"
],
"type": "Person"
},
{
"affiliation": {
"alternateName": "Universit\u00e4tsklinikum Gie\u00dfen und Marburg",
"id": "https://www.grid.ac/institutes/grid.411067.5",
"name": [
"Medizinisches Zentrum f\u00fcr Radiologie, Abteilung f\u00fcr Strahlendiagnostik, Klinikum der Philipps-Universit\u00e4t, Baldingerstrasse, D-35043 Marburg, Germany, DE"
],
"type": "Organization"
},
"familyName": "Wagner",
"givenName": "H. Joachim",
"id": "sg:person.01340510674.53",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01340510674.53"
],
"type": "Person"
},
{
"affiliation": {
"alternateName": "Universit\u00e4tsklinikum Gie\u00dfen und Marburg",
"id": "https://www.grid.ac/institutes/grid.411067.5",
"name": [
"Medizinisches Zentrum f\u00fcr Radiologie, Abteilung f\u00fcr Strahlendiagnostik, Klinikum der Philipps-Universit\u00e4t, Baldingerstrasse, D-35043 Marburg, Germany, DE"
],
"type": "Organization"
},
"familyName": "Klose",
"givenName": "Klaus J.",
"id": "sg:person.0745120173.71",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0745120173.71"
],
"type": "Person"
}
],
"citation": [
{
"id": "https://doi.org/10.1001/jama.1978.03290190031023",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1000753003"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/bf01797851",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1018589807",
"https://doi.org/10.1007/bf01797851"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/bf01797851",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1018589807",
"https://doi.org/10.1007/bf01797851"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1161/01.cir.53.4.627",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1023275957"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1161/01.cir.81.5.1575",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1027972018"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1016/0735-1097(90)90472-2",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1030178452"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1016/s0735-1097(85)80056-5",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1032148167"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1016/0735-1097(90)92142-o",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1032590084"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1161/01.cir.84.3.1087",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1037174556"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1161/01.cir.63.5.1056",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1037195278"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/bf01797856",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1038307896",
"https://doi.org/10.1007/bf01797856"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/bf01797856",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1038307896",
"https://doi.org/10.1007/bf01797856"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1111/j.1540-8175.1990.tb00381.x",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1040488779"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1002/ccd.1810080605",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1044996095"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/bf01797849",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1048330743",
"https://doi.org/10.1007/bf01797849"
],
"type": "CreativeWork"
},
{
"id": "sg:pub.10.1007/bf01797849",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1048330743",
"https://doi.org/10.1007/bf01797849"
],
"type": "CreativeWork"
}
],
"datePublished": "1997-11",
"datePublishedReg": "1997-11-01",
"description": "PURPOSE: Luminal diameters measured in vivo by calibrated-catheter angiography and by intravascular ultrasound were correlated with those obtained from pressure-fixed histologic cross-sections to determine the accuracy of both methods.\nMETHODS: Angiographic and endosonographic diameter measurements were performed in the center of stents placed in the iliac arteries of 10 miniature pigs and were compared with luminal and stent diameters in postmortem, pressure-fixed, histologic cross-sections from identical locations.\nRESULTS: Compared with histologic diameters, magnification-corrected angiographic measurements still magnified vascular luminal diameters by 0.7 +/- 0.71 mm (r = 0.41, Pearson; p < 0.003, Wilcoxon, matched pairs), whereas intravascular ultrasound measurements proved to be almost identical to the histologic lumina (r = 0.95, Pearson; p > 0. 5, Wilcoxon, matched pairs). Similarly, stent diameters correlated well between endosonographic and histologic measurements (r = 0.91; p = 0.002), and less well between angiographic and histologic diameters (r = 0.62; p = 0.002).\nCONCLUSION: Since calibrated angiography still overestimates vascular lumina, endosonography is the preferred technique for accurate in vivo measurements.",
"genre": "research_article",
"id": "sg:pub.10.1007/s002709900192",
"inLanguage": [
"en"
],
"isAccessibleForFree": false,
"isPartOf": [
{
"id": "sg:journal.1091062",
"issn": [
"0174-1551",
"1432-086X"
],
"name": "CardioVascular and Interventional Radiology",
"type": "Periodical"
},
{
"issueNumber": "6",
"type": "PublicationIssue"
},
{
"type": "PublicationVolume",
"volumeNumber": "20"
}
],
"name": "The Precise Determination of Vascular Lumen and Stent Diameters: Correlation Among Calibrated Angiography, Intravascular Ultrasound, and Pressure-Fixed Specimens",
"pagination": "452-456",
"productId": [
{
"name": "readcube_id",
"type": "PropertyValue",
"value": [
"fa453ead3d02b70bd450241059bcdb9a200901c16d01c97e175839a5cd7af540"
]
},
{
"name": "pubmed_id",
"type": "PropertyValue",
"value": [
"9354715"
]
},
{
"name": "nlm_unique_id",
"type": "PropertyValue",
"value": [
"8003538"
]
},
{
"name": "doi",
"type": "PropertyValue",
"value": [
"10.1007/s002709900192"
]
},
{
"name": "dimensions_id",
"type": "PropertyValue",
"value": [
"pub.1052540857"
]
}
],
"sameAs": [
"https://doi.org/10.1007/s002709900192",
"https://app.dimensions.ai/details/publication/pub.1052540857"
],
"sdDataset": "articles",
"sdDatePublished": "2019-04-11T00:17",
"sdLicense": "https://scigraph.springernature.com/explorer/license/",
"sdPublisher": {
"name": "Springer Nature - SN SciGraph project",
"type": "Organization"
},
"sdSource": "s3://com-uberresearch-data-dimensions-target-20181106-alternative/cleanup/v134/2549eaecd7973599484d7c17b260dba0a4ecb94b/merge/v9/a6c9fde33151104705d4d7ff012ea9563521a3ce/jats-lookup/v90/0000000001_0000000264/records_8695_00000516.jsonl",
"type": "ScholarlyArticle",
"url": "http://link.springer.com/10.1007%2Fs002709900192"
}
]
Download the RDF metadata as: json-ld nt turtle xml License info
JSON-LD is a popular format for linked data which is fully compatible with JSON.
curl -H 'Accept: application/ld+json' 'https://scigraph.springernature.com/pub.10.1007/s002709900192'
N-Triples is a line-based linked data format ideal for batch operations.
curl -H 'Accept: application/n-triples' 'https://scigraph.springernature.com/pub.10.1007/s002709900192'
Turtle is a human-readable linked data format.
curl -H 'Accept: text/turtle' 'https://scigraph.springernature.com/pub.10.1007/s002709900192'
RDF/XML is a standard XML format for linked data.
curl -H 'Accept: application/rdf+xml' 'https://scigraph.springernature.com/pub.10.1007/s002709900192'
This table displays all metadata directly associated to this object as RDF triples.
188 TRIPLES
21 PREDICATES
52 URIs
31 LITERALS
19 BLANK NODES