ABSTRACT

PurposeGood reduction and appropriate fixation are critical for long bone fractures, however, neither has been addressed satisfactorily. Robotic and navigation techniques can help improve the reduction accuracy. However, their clinical applications are limited by high cost and complexity in operation. The aim of this study was to discuss the feasibility of a customized external fixator in treating long bone fractures.MethodsWe combined a computer-assisted reduction technique with 3D printing to develop a customized external fixator for treating three cases of tibial fractures. The reduction accuracy and fixation results were discussed in terms of operation time, X-ray examinations after operation, and limb function recovery.ResultsGood reduction results were obtained on all three tibial fractures with an average lateral displacement of 2.04 mm (±1.53) and an angulation of 2.54° (±1.33). The surgery was not experience-dependent, and no intra-operative X-ray examinations were conducted. The average operative time was 8.67 minutes (±0.58).ConclusionsA novel customized external fixator for the treatment of tibial fractures has the advantages of easy manipulation, accurate reduction, appropriate fixation, minimal invasion and experience-independence, and therefore has huge potential in clinical applications. More... »

PAGES

835-841

Identifiers

URI

http://scigraph.springernature.com/pub.10.1007/s00264-015-2943-z

DOI

http://dx.doi.org/10.1007/s00264-015-2943-z

DIMENSIONS

https://app.dimensions.ai/details/publication/pub.1032843376

PUBMED

https://www.ncbi.nlm.nih.gov/pubmed/26239534


Indexing Status Check whether this publication has been indexed by Scopus and Web Of Science using the SN Indexing Status Tool
Incoming Citations Browse incoming citations for this publication using opencitations.net

JSON-LD is the canonical representation for SciGraph data.

TIP: You can open this SciGraph record using an external JSON-LD service: JSON-LD Playground Google SDTT

[
  {
    "@context": "https://springernature.github.io/scigraph/jsonld/sgcontext.json", 
    "about": [
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/11", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "name": "Medical and Health Sciences", 
        "type": "DefinedTerm"
      }, 
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/1103", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "name": "Clinical Sciences", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Adult", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "External Fixators", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Feasibility Studies", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Fracture Fixation", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Humans", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Imaging, Three-Dimensional", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Male", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Printing, Three-Dimensional", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Surgery, Computer-Assisted", 
        "type": "DefinedTerm"
      }, 
      {
        "inDefinedTermSet": "https://www.nlm.nih.gov/mesh/", 
        "name": "Tibial Fractures", 
        "type": "DefinedTerm"
      }
    ], 
    "author": [
      {
        "affiliation": {
          "alternateName": "Xi\u2019an Hong Hui Hospital, No.555, Youyidong Rd, 710054, Xi\u2019an, Shaanxi, China", 
          "id": "http://www.grid.ac/institutes/grid.452452.0", 
          "name": [
            "Hong-Hui Hospital, College of Medicine, Xi\u2019an Jiaotong University, 710054, Xi\u2019an, Shaanxi, China", 
            "Xi\u2019an Hong Hui Hospital, No.555, Youyidong Rd, 710054, Xi\u2019an, Shaanxi, China"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Qiao", 
        "givenName": "Feng", 
        "id": "sg:person.0757061671.63", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0757061671.63"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi\u2019an Jiaotong University, 710054, Xi\u2019an, Shaanxi, China", 
          "id": "http://www.grid.ac/institutes/grid.43169.39", 
          "name": [
            "Department of Orthopaedics, Second Affiliated Hospital, Xi\u2019an Jiaotong University, 710004, Xi\u2019an, Shaanxi, China", 
            "State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi\u2019an Jiaotong University, 710054, Xi\u2019an, Shaanxi, China"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Li", 
        "givenName": "Dichen", 
        "id": "sg:person.01217336374.99", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01217336374.99"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, LS2 9JT, Leeds, UK", 
          "id": "http://www.grid.ac/institutes/grid.9909.9", 
          "name": [
            "State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi\u2019an Jiaotong University, 710054, Xi\u2019an, Shaanxi, China", 
            "Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, LS2 9JT, Leeds, UK"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Jin", 
        "givenName": "Zhongmin", 
        "id": "sg:person.0652331067.71", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0652331067.71"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Hong-Hui Hospital, College of Medicine, Xi\u2019an Jiaotong University, 710054, Xi\u2019an, Shaanxi, China", 
          "id": "http://www.grid.ac/institutes/grid.452452.0", 
          "name": [
            "Hong-Hui Hospital, College of Medicine, Xi\u2019an Jiaotong University, 710054, Xi\u2019an, Shaanxi, China"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Hao", 
        "givenName": "Dingjun", 
        "id": "sg:person.012777353465.36", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.012777353465.36"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Hong-Hui Hospital, College of Medicine, Xi\u2019an Jiaotong University, 710054, Xi\u2019an, Shaanxi, China", 
          "id": "http://www.grid.ac/institutes/grid.452452.0", 
          "name": [
            "Hong-Hui Hospital, College of Medicine, Xi\u2019an Jiaotong University, 710054, Xi\u2019an, Shaanxi, China"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Liao", 
        "givenName": "Yonghua", 
        "id": "sg:person.0725546223.61", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0725546223.61"
        ], 
        "type": "Person"
      }, 
      {
        "affiliation": {
          "alternateName": "Hong-Hui Hospital, College of Medicine, Xi\u2019an Jiaotong University, 710054, Xi\u2019an, Shaanxi, China", 
          "id": "http://www.grid.ac/institutes/grid.452452.0", 
          "name": [
            "Hong-Hui Hospital, College of Medicine, Xi\u2019an Jiaotong University, 710054, Xi\u2019an, Shaanxi, China"
          ], 
          "type": "Organization"
        }, 
        "familyName": "Gong", 
        "givenName": "Sihai", 
        "id": "sg:person.0773661423.05", 
        "sameAs": [
          "https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0773661423.05"
        ], 
        "type": "Person"
      }
    ], 
    "citation": [
      {
        "id": "sg:pub.10.1007/s00264-014-2607-4", 
        "sameAs": [
          "https://app.dimensions.ai/details/publication/pub.1019628997", 
          "https://doi.org/10.1007/s00264-014-2607-4"
        ], 
        "type": "CreativeWork"
      }, 
      {
        "id": "sg:pub.10.1007/s00264-015-2681-2", 
        "sameAs": [
          "https://app.dimensions.ai/details/publication/pub.1016340864", 
          "https://doi.org/10.1007/s00264-015-2681-2"
        ], 
        "type": "CreativeWork"
      }, 
      {
        "id": "sg:pub.10.1038/35088122", 
        "sameAs": [
          "https://app.dimensions.ai/details/publication/pub.1042346615", 
          "https://doi.org/10.1038/35088122"
        ], 
        "type": "CreativeWork"
      }, 
      {
        "id": "sg:pub.10.1007/s00264-014-2294-1", 
        "sameAs": [
          "https://app.dimensions.ai/details/publication/pub.1046193587", 
          "https://doi.org/10.1007/s00264-014-2294-1"
        ], 
        "type": "CreativeWork"
      }
    ], 
    "datePublished": "2015-08-04", 
    "datePublishedReg": "2015-08-04", 
    "description": "PurposeGood reduction and appropriate fixation are critical for long bone fractures, however, neither has been addressed satisfactorily. Robotic and navigation techniques can help improve the reduction accuracy. However, their clinical applications are limited by high cost and complexity in operation. The aim of this study was to discuss the feasibility of a customized external fixator in treating long bone fractures.MethodsWe combined a computer-assisted reduction technique with 3D printing to develop a customized external fixator for treating three cases of tibial fractures. The reduction accuracy and fixation results were discussed in terms of operation time, X-ray examinations after operation, and limb function recovery.ResultsGood reduction results were obtained on all three tibial fractures with an average lateral displacement of 2.04\u00a0mm (\u00b11.53) and an angulation of 2.54\u00b0 (\u00b11.33). The surgery was not experience-dependent, and no intra-operative X-ray examinations were conducted. The average operative time was 8.67\u00a0minutes (\u00b10.58).ConclusionsA novel customized external fixator for the treatment of tibial fractures has the advantages of easy manipulation, accurate reduction, appropriate fixation, minimal invasion and experience-independence, and therefore has huge potential in clinical applications.", 
    "genre": "article", 
    "id": "sg:pub.10.1007/s00264-015-2943-z", 
    "inLanguage": "en", 
    "isAccessibleForFree": false, 
    "isPartOf": [
      {
        "id": "sg:journal.1086603", 
        "issn": [
          "0341-2695", 
          "1432-5195"
        ], 
        "name": "International Orthopaedics", 
        "publisher": "Springer Nature", 
        "type": "Periodical"
      }, 
      {
        "issueNumber": "4", 
        "type": "PublicationIssue"
      }, 
      {
        "type": "PublicationVolume", 
        "volumeNumber": "40"
      }
    ], 
    "keywords": [
      "reduction accuracy", 
      "reduction techniques", 
      "lateral displacement", 
      "huge potential", 
      "fractures", 
      "navigation techniques", 
      "average lateral displacement", 
      "high cost", 
      "printing", 
      "appropriate fixation", 
      "operation", 
      "reduction results", 
      "easy manipulation", 
      "applications", 
      "accuracy", 
      "technique", 
      "long bone fractures", 
      "external fixator", 
      "displacement", 
      "operation time", 
      "novel combination", 
      "bone fractures", 
      "feasibility", 
      "limb function recovery", 
      "reduction", 
      "results", 
      "cost", 
      "advantages", 
      "fixator", 
      "clinical applications", 
      "time", 
      "accurate reduction", 
      "fixation results", 
      "recovery", 
      "combination", 
      "potential", 
      "terms", 
      "novel", 
      "complexity", 
      "fixation", 
      "tibial fractures", 
      "minimal invasion", 
      "cases", 
      "study", 
      "manipulation", 
      "angulation", 
      "treatment", 
      "minutes", 
      "aim", 
      "ray examination", 
      "examination", 
      "function recovery", 
      "surgery", 
      "operative time", 
      "average operative time", 
      "MethodsWe", 
      "invasion", 
      "PurposeGood reduction", 
      "computer-assisted reduction technique", 
      "customized external fixator", 
      "ResultsGood reduction results", 
      "ConclusionsA novel", 
      "patient-specific external fixator"
    ], 
    "name": "A novel combination of computer-assisted reduction technique and three dimensional printed patient-specific external fixator for treatment of tibial fractures", 
    "pagination": "835-841", 
    "productId": [
      {
        "name": "dimensions_id", 
        "type": "PropertyValue", 
        "value": [
          "pub.1032843376"
        ]
      }, 
      {
        "name": "doi", 
        "type": "PropertyValue", 
        "value": [
          "10.1007/s00264-015-2943-z"
        ]
      }, 
      {
        "name": "pubmed_id", 
        "type": "PropertyValue", 
        "value": [
          "26239534"
        ]
      }
    ], 
    "sameAs": [
      "https://doi.org/10.1007/s00264-015-2943-z", 
      "https://app.dimensions.ai/details/publication/pub.1032843376"
    ], 
    "sdDataset": "articles", 
    "sdDatePublished": "2022-01-01T18:36", 
    "sdLicense": "https://scigraph.springernature.com/explorer/license/", 
    "sdPublisher": {
      "name": "Springer Nature - SN SciGraph project", 
      "type": "Organization"
    }, 
    "sdSource": "s3://com-springernature-scigraph/baseset/20220101/entities/gbq_results/article/article_666.jsonl", 
    "type": "ScholarlyArticle", 
    "url": "https://doi.org/10.1007/s00264-015-2943-z"
  }
]
 

Download the RDF metadata as:  json-ld nt turtle xml License info

HOW TO GET THIS DATA PROGRAMMATICALLY:

JSON-LD is a popular format for linked data which is fully compatible with JSON.

curl -H 'Accept: application/ld+json' 'https://scigraph.springernature.com/pub.10.1007/s00264-015-2943-z'

N-Triples is a line-based linked data format ideal for batch operations.

curl -H 'Accept: application/n-triples' 'https://scigraph.springernature.com/pub.10.1007/s00264-015-2943-z'

Turtle is a human-readable linked data format.

curl -H 'Accept: text/turtle' 'https://scigraph.springernature.com/pub.10.1007/s00264-015-2943-z'

RDF/XML is a standard XML format for linked data.

curl -H 'Accept: application/rdf+xml' 'https://scigraph.springernature.com/pub.10.1007/s00264-015-2943-z'


 

This table displays all metadata directly associated to this object as RDF triples.

226 TRIPLES      22 PREDICATES      103 URIs      91 LITERALS      17 BLANK NODES

Subject Predicate Object
1 sg:pub.10.1007/s00264-015-2943-z schema:about N296f48bbe3724fbabeb6c888a983b6dd
2 N3875339e0b4c447a9c2371c56d75cd38
3 N46dd2c48850a4091af6d65fd0fc78ae5
4 N54438276d0fe43509284a10e21861ce6
5 Na76c445bd12b4d13a49f927582847475
6 Nd4ff4712404149d5b37a71f13e86186e
7 Ne4cd5884bb93457f8557430b67eb99b5
8 Nef236090a6474ebe9aa40bd68ceae4c3
9 Nf319f9b4d53b4f3780968426061037f6
10 Nf510be39323447bc9a18474bd3b5536a
11 anzsrc-for:11
12 anzsrc-for:1103
13 schema:author Nec5ec92249b7412aa57e4474d76098da
14 schema:citation sg:pub.10.1007/s00264-014-2294-1
15 sg:pub.10.1007/s00264-014-2607-4
16 sg:pub.10.1007/s00264-015-2681-2
17 sg:pub.10.1038/35088122
18 schema:datePublished 2015-08-04
19 schema:datePublishedReg 2015-08-04
20 schema:description PurposeGood reduction and appropriate fixation are critical for long bone fractures, however, neither has been addressed satisfactorily. Robotic and navigation techniques can help improve the reduction accuracy. However, their clinical applications are limited by high cost and complexity in operation. The aim of this study was to discuss the feasibility of a customized external fixator in treating long bone fractures.MethodsWe combined a computer-assisted reduction technique with 3D printing to develop a customized external fixator for treating three cases of tibial fractures. The reduction accuracy and fixation results were discussed in terms of operation time, X-ray examinations after operation, and limb function recovery.ResultsGood reduction results were obtained on all three tibial fractures with an average lateral displacement of 2.04 mm (±1.53) and an angulation of 2.54° (±1.33). The surgery was not experience-dependent, and no intra-operative X-ray examinations were conducted. The average operative time was 8.67 minutes (±0.58).ConclusionsA novel customized external fixator for the treatment of tibial fractures has the advantages of easy manipulation, accurate reduction, appropriate fixation, minimal invasion and experience-independence, and therefore has huge potential in clinical applications.
21 schema:genre article
22 schema:inLanguage en
23 schema:isAccessibleForFree false
24 schema:isPartOf N02a55f8de8714941b9b0d4f2fab40373
25 N178f9c49cdc84454bb688d229cd3e30b
26 sg:journal.1086603
27 schema:keywords ConclusionsA novel
28 MethodsWe
29 PurposeGood reduction
30 ResultsGood reduction results
31 accuracy
32 accurate reduction
33 advantages
34 aim
35 angulation
36 applications
37 appropriate fixation
38 average lateral displacement
39 average operative time
40 bone fractures
41 cases
42 clinical applications
43 combination
44 complexity
45 computer-assisted reduction technique
46 cost
47 customized external fixator
48 displacement
49 easy manipulation
50 examination
51 external fixator
52 feasibility
53 fixation
54 fixation results
55 fixator
56 fractures
57 function recovery
58 high cost
59 huge potential
60 invasion
61 lateral displacement
62 limb function recovery
63 long bone fractures
64 manipulation
65 minimal invasion
66 minutes
67 navigation techniques
68 novel
69 novel combination
70 operation
71 operation time
72 operative time
73 patient-specific external fixator
74 potential
75 printing
76 ray examination
77 recovery
78 reduction
79 reduction accuracy
80 reduction results
81 reduction techniques
82 results
83 study
84 surgery
85 technique
86 terms
87 tibial fractures
88 time
89 treatment
90 schema:name A novel combination of computer-assisted reduction technique and three dimensional printed patient-specific external fixator for treatment of tibial fractures
91 schema:pagination 835-841
92 schema:productId Na8914cd9f21447238a32bf495760836c
93 Nb08afc7761b2449da1e221763448d35d
94 Nffc87ea3782449e3ac7b3d25aab95ece
95 schema:sameAs https://app.dimensions.ai/details/publication/pub.1032843376
96 https://doi.org/10.1007/s00264-015-2943-z
97 schema:sdDatePublished 2022-01-01T18:36
98 schema:sdLicense https://scigraph.springernature.com/explorer/license/
99 schema:sdPublisher N8ec724ee435d4bd99702462a2722104a
100 schema:url https://doi.org/10.1007/s00264-015-2943-z
101 sgo:license sg:explorer/license/
102 sgo:sdDataset articles
103 rdf:type schema:ScholarlyArticle
104 N02a55f8de8714941b9b0d4f2fab40373 schema:issueNumber 4
105 rdf:type schema:PublicationIssue
106 N178f9c49cdc84454bb688d229cd3e30b schema:volumeNumber 40
107 rdf:type schema:PublicationVolume
108 N1bbaec20024c47b0a129d91459eb3fbe rdf:first sg:person.0773661423.05
109 rdf:rest rdf:nil
110 N2284d978e31e40c18021590bd76da4e3 rdf:first sg:person.01217336374.99
111 rdf:rest Ndac324b44d5b4f9a87f18f93cb7d41e4
112 N296f48bbe3724fbabeb6c888a983b6dd schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
113 schema:name Adult
114 rdf:type schema:DefinedTerm
115 N3875339e0b4c447a9c2371c56d75cd38 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
116 schema:name External Fixators
117 rdf:type schema:DefinedTerm
118 N46dd2c48850a4091af6d65fd0fc78ae5 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
119 schema:name Fracture Fixation
120 rdf:type schema:DefinedTerm
121 N54438276d0fe43509284a10e21861ce6 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
122 schema:name Imaging, Three-Dimensional
123 rdf:type schema:DefinedTerm
124 N6ac45dbfeedd402c9e413e22f2f79761 rdf:first sg:person.0725546223.61
125 rdf:rest N1bbaec20024c47b0a129d91459eb3fbe
126 N80da5989f82b41ee9357df3344861582 rdf:first sg:person.012777353465.36
127 rdf:rest N6ac45dbfeedd402c9e413e22f2f79761
128 N8ec724ee435d4bd99702462a2722104a schema:name Springer Nature - SN SciGraph project
129 rdf:type schema:Organization
130 Na76c445bd12b4d13a49f927582847475 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
131 schema:name Humans
132 rdf:type schema:DefinedTerm
133 Na8914cd9f21447238a32bf495760836c schema:name pubmed_id
134 schema:value 26239534
135 rdf:type schema:PropertyValue
136 Nb08afc7761b2449da1e221763448d35d schema:name dimensions_id
137 schema:value pub.1032843376
138 rdf:type schema:PropertyValue
139 Nd4ff4712404149d5b37a71f13e86186e schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
140 schema:name Printing, Three-Dimensional
141 rdf:type schema:DefinedTerm
142 Ndac324b44d5b4f9a87f18f93cb7d41e4 rdf:first sg:person.0652331067.71
143 rdf:rest N80da5989f82b41ee9357df3344861582
144 Ne4cd5884bb93457f8557430b67eb99b5 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
145 schema:name Tibial Fractures
146 rdf:type schema:DefinedTerm
147 Nec5ec92249b7412aa57e4474d76098da rdf:first sg:person.0757061671.63
148 rdf:rest N2284d978e31e40c18021590bd76da4e3
149 Nef236090a6474ebe9aa40bd68ceae4c3 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
150 schema:name Male
151 rdf:type schema:DefinedTerm
152 Nf319f9b4d53b4f3780968426061037f6 schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
153 schema:name Feasibility Studies
154 rdf:type schema:DefinedTerm
155 Nf510be39323447bc9a18474bd3b5536a schema:inDefinedTermSet https://www.nlm.nih.gov/mesh/
156 schema:name Surgery, Computer-Assisted
157 rdf:type schema:DefinedTerm
158 Nffc87ea3782449e3ac7b3d25aab95ece schema:name doi
159 schema:value 10.1007/s00264-015-2943-z
160 rdf:type schema:PropertyValue
161 anzsrc-for:11 schema:inDefinedTermSet anzsrc-for:
162 schema:name Medical and Health Sciences
163 rdf:type schema:DefinedTerm
164 anzsrc-for:1103 schema:inDefinedTermSet anzsrc-for:
165 schema:name Clinical Sciences
166 rdf:type schema:DefinedTerm
167 sg:journal.1086603 schema:issn 0341-2695
168 1432-5195
169 schema:name International Orthopaedics
170 schema:publisher Springer Nature
171 rdf:type schema:Periodical
172 sg:person.01217336374.99 schema:affiliation grid-institutes:grid.43169.39
173 schema:familyName Li
174 schema:givenName Dichen
175 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01217336374.99
176 rdf:type schema:Person
177 sg:person.012777353465.36 schema:affiliation grid-institutes:grid.452452.0
178 schema:familyName Hao
179 schema:givenName Dingjun
180 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.012777353465.36
181 rdf:type schema:Person
182 sg:person.0652331067.71 schema:affiliation grid-institutes:grid.9909.9
183 schema:familyName Jin
184 schema:givenName Zhongmin
185 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0652331067.71
186 rdf:type schema:Person
187 sg:person.0725546223.61 schema:affiliation grid-institutes:grid.452452.0
188 schema:familyName Liao
189 schema:givenName Yonghua
190 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0725546223.61
191 rdf:type schema:Person
192 sg:person.0757061671.63 schema:affiliation grid-institutes:grid.452452.0
193 schema:familyName Qiao
194 schema:givenName Feng
195 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0757061671.63
196 rdf:type schema:Person
197 sg:person.0773661423.05 schema:affiliation grid-institutes:grid.452452.0
198 schema:familyName Gong
199 schema:givenName Sihai
200 schema:sameAs https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.0773661423.05
201 rdf:type schema:Person
202 sg:pub.10.1007/s00264-014-2294-1 schema:sameAs https://app.dimensions.ai/details/publication/pub.1046193587
203 https://doi.org/10.1007/s00264-014-2294-1
204 rdf:type schema:CreativeWork
205 sg:pub.10.1007/s00264-014-2607-4 schema:sameAs https://app.dimensions.ai/details/publication/pub.1019628997
206 https://doi.org/10.1007/s00264-014-2607-4
207 rdf:type schema:CreativeWork
208 sg:pub.10.1007/s00264-015-2681-2 schema:sameAs https://app.dimensions.ai/details/publication/pub.1016340864
209 https://doi.org/10.1007/s00264-015-2681-2
210 rdf:type schema:CreativeWork
211 sg:pub.10.1038/35088122 schema:sameAs https://app.dimensions.ai/details/publication/pub.1042346615
212 https://doi.org/10.1038/35088122
213 rdf:type schema:CreativeWork
214 grid-institutes:grid.43169.39 schema:alternateName State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi’an Jiaotong University, 710054, Xi’an, Shaanxi, China
215 schema:name Department of Orthopaedics, Second Affiliated Hospital, Xi’an Jiaotong University, 710004, Xi’an, Shaanxi, China
216 State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi’an Jiaotong University, 710054, Xi’an, Shaanxi, China
217 rdf:type schema:Organization
218 grid-institutes:grid.452452.0 schema:alternateName Hong-Hui Hospital, College of Medicine, Xi’an Jiaotong University, 710054, Xi’an, Shaanxi, China
219 Xi’an Hong Hui Hospital, No.555, Youyidong Rd, 710054, Xi’an, Shaanxi, China
220 schema:name Hong-Hui Hospital, College of Medicine, Xi’an Jiaotong University, 710054, Xi’an, Shaanxi, China
221 Xi’an Hong Hui Hospital, No.555, Youyidong Rd, 710054, Xi’an, Shaanxi, China
222 rdf:type schema:Organization
223 grid-institutes:grid.9909.9 schema:alternateName Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, LS2 9JT, Leeds, UK
224 schema:name Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, LS2 9JT, Leeds, UK
225 State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi’an Jiaotong University, 710054, Xi’an, Shaanxi, China
226 rdf:type schema:Organization
 




Preview window. Press ESC to close (or click here)


...