Ontology type: schema:ScholarlyArticle
2005-06
AUTHORSB. J. Healy, A. Gibbs, R. L. Murry, J. E. Prunster, K. N. Nitschke
ABSTRACTOutput factors at the surface for treatment cones and lead cut-outs have been measured for a Pantak Therapax SXT 150 superficial therapy unit with x-ray beam qualities from 1 to 13 mm A1 HVL. A variety of phantom materials and two ionisation chambers were tested for their suitability in output factor and percentage depth dose measurement. Solid water proved a useful water-equivalent phantom material with discrepancies between measurements in water and solid water less than 2.3% for percentage depth dose and less than 0.6% for output factors. Larger measurement discrepancies were found for Plastic Water and Perspex. A PTW Markus chamber was found to compare well with a NE 2532/3 low energy chamber in percentage depth dose measurement, but discrepancies arose between the chambers in output factor measurements, up to 5% for small field sizes. Measurements indicated that the Markus chamber had an energy dependent response in the kilovoltage range, which could account for the discrepancy in output factor measurement. More... »
PAGES115
http://scigraph.springernature.com/pub.10.1007/bf03178702
DOIhttp://dx.doi.org/10.1007/bf03178702
DIMENSIONShttps://app.dimensions.ai/details/publication/pub.1004592200
PUBMEDhttps://www.ncbi.nlm.nih.gov/pubmed/16060318
JSON-LD is the canonical representation for SciGraph data.
TIP: You can open this SciGraph record using an external JSON-LD service: JSON-LD Playground Google SDTT
[
{
"@context": "https://springernature.github.io/scigraph/jsonld/sgcontext.json",
"about": [
{
"id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/0299",
"inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/",
"name": "Other Physical Sciences",
"type": "DefinedTerm"
},
{
"id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/02",
"inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/",
"name": "Physical Sciences",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Australia",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Equipment Failure Analysis",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Guidelines as Topic",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Quality Assurance, Health Care",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Radiation Dosage",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Radiometry",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "Reference Standards",
"type": "DefinedTerm"
},
{
"inDefinedTermSet": "https://www.nlm.nih.gov/mesh/",
"name": "X-Ray Therapy",
"type": "DefinedTerm"
}
],
"author": [
{
"affiliation": {
"alternateName": "Princess Alexandra Hospital",
"id": "https://www.grid.ac/institutes/grid.412744.0",
"name": [
"Southern Zone Radiation Oncology Service-Mater Centre, Princess Alexandra Hospital, Raymond Tce., 4101, South Brisbane, Queensland, Australia"
],
"type": "Organization"
},
"familyName": "Healy",
"givenName": "B. J.",
"id": "sg:person.01152226472.51",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01152226472.51"
],
"type": "Person"
},
{
"affiliation": {
"alternateName": "Princess Alexandra Hospital",
"id": "https://www.grid.ac/institutes/grid.412744.0",
"name": [
"Southern Zone Radiation Oncology Service-Mater Centre, Princess Alexandra Hospital, Raymond Tce., 4101, South Brisbane, Queensland, Australia"
],
"type": "Organization"
},
"familyName": "Gibbs",
"givenName": "A.",
"type": "Person"
},
{
"affiliation": {
"alternateName": "Princess Alexandra Hospital",
"id": "https://www.grid.ac/institutes/grid.412744.0",
"name": [
"Southern Zone Radiation Oncology Service-Mater Centre, Princess Alexandra Hospital, Raymond Tce., 4101, South Brisbane, Queensland, Australia"
],
"type": "Organization"
},
"familyName": "Murry",
"givenName": "R. L.",
"id": "sg:person.01217073232.97",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01217073232.97"
],
"type": "Person"
},
{
"affiliation": {
"alternateName": "Princess Alexandra Hospital",
"id": "https://www.grid.ac/institutes/grid.412744.0",
"name": [
"Southern Zone Radiation Oncology Service-Mater Centre, Princess Alexandra Hospital, Raymond Tce., 4101, South Brisbane, Queensland, Australia"
],
"type": "Organization"
},
"familyName": "Prunster",
"givenName": "J. E.",
"type": "Person"
},
{
"affiliation": {
"alternateName": "Princess Alexandra Hospital",
"id": "https://www.grid.ac/institutes/grid.412744.0",
"name": [
"Southern Zone Radiation Oncology Service-Mater Centre, Princess Alexandra Hospital, Raymond Tce., 4101, South Brisbane, Queensland, Australia"
],
"type": "Organization"
},
"familyName": "Nitschke",
"givenName": "K. N.",
"id": "sg:person.01202157474.96",
"sameAs": [
"https://app.dimensions.ai/discover/publication?and_facet_researcher=ur.01202157474.96"
],
"type": "Person"
}
],
"citation": [
{
"id": "https://doi.org/10.1118/1.597899",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1008510234"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1118/1.595063",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1022544072"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1118/1.597232",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1032440790"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1118/1.598309",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1040559963"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1118/1.597613",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1045254752"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1118/1.1374247",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1049969827"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1088/0031-9155/27/8/005",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1059020909"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1088/0031-9155/36/8/006",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1059022179"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1088/0031-9155/41/12/002",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1059022925"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1088/0031-9155/42/12/019",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1059023123"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1088/0031-9155/46/7/318",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1059024347"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1088/0031-9155/46/8/306",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1059024359"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1097/00004032-200111000-00017",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1060181939"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1097/00004032-200111000-00017",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1060181939"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1097/00004032-200111000-00017",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1060181939"
],
"type": "CreativeWork"
},
{
"id": "https://doi.org/10.1259/0007-1285-22-261-540",
"sameAs": [
"https://app.dimensions.ai/details/publication/pub.1064543140"
],
"type": "CreativeWork"
},
{
"id": "https://app.dimensions.ai/details/publication/pub.1083319274",
"type": "CreativeWork"
}
],
"datePublished": "2005-06",
"datePublishedReg": "2005-06-01",
"description": "Output factors at the surface for treatment cones and lead cut-outs have been measured for a Pantak Therapax SXT 150 superficial therapy unit with x-ray beam qualities from 1 to 13 mm A1 HVL. A variety of phantom materials and two ionisation chambers were tested for their suitability in output factor and percentage depth dose measurement. Solid water proved a useful water-equivalent phantom material with discrepancies between measurements in water and solid water less than 2.3% for percentage depth dose and less than 0.6% for output factors. Larger measurement discrepancies were found for Plastic Water and Perspex. A PTW Markus chamber was found to compare well with a NE 2532/3 low energy chamber in percentage depth dose measurement, but discrepancies arose between the chambers in output factor measurements, up to 5% for small field sizes. Measurements indicated that the Markus chamber had an energy dependent response in the kilovoltage range, which could account for the discrepancy in output factor measurement.",
"genre": "research_article",
"id": "sg:pub.10.1007/bf03178702",
"inLanguage": [
"en"
],
"isAccessibleForFree": false,
"isPartOf": [
{
"id": "sg:journal.1093172",
"issn": [
"0158-9938",
"1879-5447"
],
"name": "Australasian Physical & Engineering Sciences in Medicine",
"type": "Periodical"
},
{
"issueNumber": "2",
"type": "PublicationIssue"
},
{
"type": "PublicationVolume",
"volumeNumber": "28"
}
],
"name": "Output factor measurements for a kilovoltage x-ray therapy unit",
"pagination": "115",
"productId": [
{
"name": "readcube_id",
"type": "PropertyValue",
"value": [
"15e1e91bc1aaf32116e41206627fea94e18871670b2fc62354c873e5fa50c1c6"
]
},
{
"name": "pubmed_id",
"type": "PropertyValue",
"value": [
"16060318"
]
},
{
"name": "nlm_unique_id",
"type": "PropertyValue",
"value": [
"8208130"
]
},
{
"name": "doi",
"type": "PropertyValue",
"value": [
"10.1007/bf03178702"
]
},
{
"name": "dimensions_id",
"type": "PropertyValue",
"value": [
"pub.1004592200"
]
}
],
"sameAs": [
"https://doi.org/10.1007/bf03178702",
"https://app.dimensions.ai/details/publication/pub.1004592200"
],
"sdDataset": "articles",
"sdDatePublished": "2019-04-11T10:00",
"sdLicense": "https://scigraph.springernature.com/explorer/license/",
"sdPublisher": {
"name": "Springer Nature - SN SciGraph project",
"type": "Organization"
},
"sdSource": "s3://com-uberresearch-data-dimensions-target-20181106-alternative/cleanup/v134/2549eaecd7973599484d7c17b260dba0a4ecb94b/merge/v9/a6c9fde33151104705d4d7ff012ea9563521a3ce/jats-lookup/v90/0000000347_0000000347/records_89816_00000000.jsonl",
"type": "ScholarlyArticle",
"url": "http://link.springer.com/10.1007%2FBF03178702"
}
]
Download the RDF metadata as: json-ld nt turtle xml License info
JSON-LD is a popular format for linked data which is fully compatible with JSON.
curl -H 'Accept: application/ld+json' 'https://scigraph.springernature.com/pub.10.1007/bf03178702'
N-Triples is a line-based linked data format ideal for batch operations.
curl -H 'Accept: application/n-triples' 'https://scigraph.springernature.com/pub.10.1007/bf03178702'
Turtle is a human-readable linked data format.
curl -H 'Accept: text/turtle' 'https://scigraph.springernature.com/pub.10.1007/bf03178702'
RDF/XML is a standard XML format for linked data.
curl -H 'Accept: application/rdf+xml' 'https://scigraph.springernature.com/pub.10.1007/bf03178702'
This table displays all metadata directly associated to this object as RDF triples.
171 TRIPLES
21 PREDICATES
52 URIs
29 LITERALS
17 BLANK NODES