The mechanism of mass spectrometer working in the atmosphere or low vacuum will be researched in this paper.The difference of ion moving between in the vacuum and in the atmosphere(or low vacuum) is the resistance that the pressure is more higher,the resistance is more greater. In the vacuum, the pattern of ion's moving can be described by Mathieu Function,because the resistance is close to zero. But in the atmosphere or low vacuum, the pattern of ion's moving can't be described by Mathieu Function,because the resistance is not zero.So the mathieu must be modified to establish a new and suitable theoretical model. The pattern of ion's moving in the atmosphere or low vacuum that can cause resistance is the main content of this paper. First,a model of ion's moving will be established by modifing the Mathieu Funciton. Second,the pattern of ion's moving in the airflow field and electric field will be simulated by the software COMSOL. A method of controlling the ions in the atmosphere or low vacuum will be found. At last, by changing the pressure,the previous simulation will be test in the MS experiment platform. . Theoretically, this research reduces the requirements for the vacuum of the traditional mass spectrometer. So the cost, power consumption, volume and weight of mass spectrometer will be reduced. It will be used widely in the field of site testing such as food safety,environmental monitoring etc. More... »

URL

https://kd.nsfc.gov.cn/finalDetails?id=7e0e2580ff4b718aef3caef8033bc7e7

Related SciGraph Publications

  • 2017-06-28. A novel ion detector aiming at the homogeneous of drift gas in INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY
  • JSON-LD is the canonical representation for SciGraph data.

    TIP: You can open this SciGraph record using an external JSON-LD service: JSON-LD Playground Google SDTT

    [
      {
        "@context": "https://springernature.github.io/scigraph/jsonld/sgcontext.json", 
        "about": [
          {
            "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/34", 
            "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
            "type": "DefinedTerm"
          }
        ], 
        "amount": {
          "currency": "CNY", 
          "type": "MonetaryAmount", 
          "value": 210000.0
        }, 
        "description": "The mechanism of mass spectrometer working in the atmosphere or low vacuum will be researched in this paper.The difference of ion moving between in the vacuum and in the atmosphere(or low vacuum) is the resistance that the pressure is more higher,the resistance is more greater. In the vacuum, the pattern of ion's moving can be described by Mathieu Function,because the resistance is close to zero. But in the atmosphere or low vacuum, the pattern of ion's moving can't be described by Mathieu Function,because the resistance is not zero.So the mathieu must be modified to establish a new and suitable theoretical model. The pattern of ion's moving in the atmosphere or low vacuum that can cause resistance is the main content of this paper. First,a model of ion's moving will be established by modifing the Mathieu Funciton. Second,the pattern of ion's moving in the airflow field and electric field will be simulated by the software COMSOL. A method of controlling the ions in the atmosphere or low vacuum will be found. At last, by changing the pressure,the previous simulation will be test in the MS experiment platform. .     Theoretically, this research reduces the requirements for the vacuum of the traditional mass spectrometer. So the cost, power consumption, volume and weight of mass spectrometer will be reduced. It will be used widely in the field of site testing such as food safety,environmental monitoring etc.", 
        "endDate": "2018-12-31", 
        "funder": {
          "id": "http://www.grid.ac/institutes/grid.419696.5", 
          "type": "Organization"
        }, 
        "id": "sg:grant.8150834", 
        "identifier": [
          {
            "name": "dimensions_id", 
            "type": "PropertyValue", 
            "value": [
              "grant.8150834"
            ]
          }, 
          {
            "name": "nsfc_id", 
            "type": "PropertyValue", 
            "value": [
              "21505028"
            ]
          }
        ], 
        "keywords": [
          "low vacuum", 
          "mass spectrometer", 
          "traditional mass spectrometers", 
          "difference of ion", 
          "suitable theoretical model", 
          "electric field", 
          "mass spectrometry", 
          "vacuum", 
          "Mathieu functions", 
          "spectrometer", 
          "previous simulations", 
          "ions", 
          "mechanism study", 
          "atmosphere", 
          "theoretical model", 
          "environmental monitoring", 
          "atmospheric environment", 
          "field", 
          "spectrometry", 
          "site testing", 
          "food safety", 
          "software COMSOL", 
          "simulations", 
          "power consumption", 
          "COMSOL", 
          "experiment platform", 
          "pressure", 
          "Mathieu", 
          "resistance", 
          "moving", 
          "function", 
          "model", 
          "mechanism", 
          "method", 
          "content", 
          "platform", 
          "weight", 
          "environment", 
          "volume", 
          "monitoring", 
          "patterns", 
          "paper", 
          "study", 
          "funciton", 
          "requirements", 
          "test", 
          "cost", 
          "airflow field", 
          "differences", 
          "consumption", 
          "testing", 
          "research", 
          "main content", 
          "safety"
        ], 
        "name": "Mechanism Study of Mass Spectrometry in Low Vacuum or Atmospheric Environment", 
        "recipient": [
          {
            "id": "http://www.grid.ac/institutes/grid.19373.3f", 
            "type": "Organization"
          }, 
          {
            "affiliation": {
              "id": "http://www.grid.ac/institutes/None", 
              "name": "Harbin Institute of Technology", 
              "type": "Organization"
            }, 
            "familyName": "Zhao", 
            "givenName": "Zhanfeng", 
            "id": "sg:person.013354165733.99", 
            "type": "Person"
          }, 
          {
            "member": "sg:person.013354165733.99", 
            "roleName": "PI", 
            "type": "Role"
          }
        ], 
        "sameAs": [
          "https://app.dimensions.ai/details/grant/grant.8150834"
        ], 
        "sdDataset": "grants", 
        "sdDatePublished": "2022-12-01T06:57", 
        "sdLicense": "https://scigraph.springernature.com/explorer/license/", 
        "sdPublisher": {
          "name": "Springer Nature - SN SciGraph project", 
          "type": "Organization"
        }, 
        "sdSource": "s3://com-springernature-scigraph/baseset/20221201/entities/gbq_results/grant/grant_5.jsonl", 
        "startDate": "2016-01-01", 
        "type": "MonetaryGrant", 
        "url": "https://kd.nsfc.gov.cn/finalDetails?id=7e0e2580ff4b718aef3caef8033bc7e7"
      }
    ]
     

    Download the RDF metadata as:  json-ld nt turtle xml License info

    HOW TO GET THIS DATA PROGRAMMATICALLY:

    JSON-LD is a popular format for linked data which is fully compatible with JSON.

    curl -H 'Accept: application/ld+json' 'https://scigraph.springernature.com/grant.8150834'

    N-Triples is a line-based linked data format ideal for batch operations.

    curl -H 'Accept: application/n-triples' 'https://scigraph.springernature.com/grant.8150834'

    Turtle is a human-readable linked data format.

    curl -H 'Accept: text/turtle' 'https://scigraph.springernature.com/grant.8150834'

    RDF/XML is a standard XML format for linked data.

    curl -H 'Accept: application/rdf+xml' 'https://scigraph.springernature.com/grant.8150834'


     

    This table displays all metadata directly associated to this object as RDF triples.

    98 TRIPLES      18 PREDICATES      75 URIs      67 LITERALS      5 BLANK NODES

    Subject Predicate Object
    1 sg:grant.8150834 schema:about anzsrc-for:34
    2 schema:amount N0987e38870cf4b4a8568b19b677fd02a
    3 schema:description The mechanism of mass spectrometer working in the atmosphere or low vacuum will be researched in this paper.The difference of ion moving between in the vacuum and in the atmosphere(or low vacuum) is the resistance that the pressure is more higher,the resistance is more greater. In the vacuum, the pattern of ion's moving can be described by Mathieu Function,because the resistance is close to zero. But in the atmosphere or low vacuum, the pattern of ion's moving can't be described by Mathieu Function,because the resistance is not zero.So the mathieu must be modified to establish a new and suitable theoretical model. The pattern of ion's moving in the atmosphere or low vacuum that can cause resistance is the main content of this paper. First,a model of ion's moving will be established by modifing the Mathieu Funciton. Second,the pattern of ion's moving in the airflow field and electric field will be simulated by the software COMSOL. A method of controlling the ions in the atmosphere or low vacuum will be found. At last, by changing the pressure,the previous simulation will be test in the MS experiment platform. . Theoretically, this research reduces the requirements for the vacuum of the traditional mass spectrometer. So the cost, power consumption, volume and weight of mass spectrometer will be reduced. It will be used widely in the field of site testing such as food safety,environmental monitoring etc.
    4 schema:endDate 2018-12-31
    5 schema:funder grid-institutes:grid.419696.5
    6 schema:identifier N5608e7bb80284bcda52fbb15296f14db
    7 Na4d9020827ff4035937231802b3775fb
    8 schema:keywords COMSOL
    9 Mathieu
    10 Mathieu functions
    11 airflow field
    12 atmosphere
    13 atmospheric environment
    14 consumption
    15 content
    16 cost
    17 difference of ion
    18 differences
    19 electric field
    20 environment
    21 environmental monitoring
    22 experiment platform
    23 field
    24 food safety
    25 funciton
    26 function
    27 ions
    28 low vacuum
    29 main content
    30 mass spectrometer
    31 mass spectrometry
    32 mechanism
    33 mechanism study
    34 method
    35 model
    36 monitoring
    37 moving
    38 paper
    39 patterns
    40 platform
    41 power consumption
    42 pressure
    43 previous simulations
    44 requirements
    45 research
    46 resistance
    47 safety
    48 simulations
    49 site testing
    50 software COMSOL
    51 spectrometer
    52 spectrometry
    53 study
    54 suitable theoretical model
    55 test
    56 testing
    57 theoretical model
    58 traditional mass spectrometers
    59 vacuum
    60 volume
    61 weight
    62 schema:name Mechanism Study of Mass Spectrometry in Low Vacuum or Atmospheric Environment
    63 schema:recipient N904a7bb664f540b3a1caabc2b0a84bd0
    64 sg:person.013354165733.99
    65 grid-institutes:grid.19373.3f
    66 schema:sameAs https://app.dimensions.ai/details/grant/grant.8150834
    67 schema:sdDatePublished 2022-12-01T06:57
    68 schema:sdLicense https://scigraph.springernature.com/explorer/license/
    69 schema:sdPublisher Ned1055d4cb0141b695db15770dc9c6de
    70 schema:startDate 2016-01-01
    71 schema:url https://kd.nsfc.gov.cn/finalDetails?id=7e0e2580ff4b718aef3caef8033bc7e7
    72 sgo:license sg:explorer/license/
    73 sgo:sdDataset grants
    74 rdf:type schema:MonetaryGrant
    75 N0987e38870cf4b4a8568b19b677fd02a schema:currency CNY
    76 schema:value 210000.0
    77 rdf:type schema:MonetaryAmount
    78 N5608e7bb80284bcda52fbb15296f14db schema:name nsfc_id
    79 schema:value 21505028
    80 rdf:type schema:PropertyValue
    81 N904a7bb664f540b3a1caabc2b0a84bd0 schema:member sg:person.013354165733.99
    82 schema:roleName PI
    83 rdf:type schema:Role
    84 Na4d9020827ff4035937231802b3775fb schema:name dimensions_id
    85 schema:value grant.8150834
    86 rdf:type schema:PropertyValue
    87 Ned1055d4cb0141b695db15770dc9c6de schema:name Springer Nature - SN SciGraph project
    88 rdf:type schema:Organization
    89 anzsrc-for:34 schema:inDefinedTermSet anzsrc-for:
    90 rdf:type schema:DefinedTerm
    91 sg:person.013354165733.99 schema:affiliation grid-institutes:None
    92 schema:familyName Zhao
    93 schema:givenName Zhanfeng
    94 rdf:type schema:Person
    95 grid-institutes:None schema:name Harbin Institute of Technology
    96 rdf:type schema:Organization
    97 grid-institutes:grid.19373.3f schema:Organization
    98 grid-institutes:grid.419696.5 schema:Organization
     




    Preview window. Press ESC to close (or click here)


    ...