Chlorine in aqueous solutions is used for a number of purposes, such as disinfection and bleaching, and also as a powerful oxidizing agent in various manufacturing processes. It is known that chlorine is highly toxic, and additionally it can further react with other substances, such as phenols, in environment to produce chlorophenols, which are suspected to be carcinogens. Thus, the development of the new methods and devices for the reliable and continuous measurement of residual chlorine at trace levels had been conducted in the present work.Residual chlorine in water is generally present in the fibrin of hypochlorous acid (HOCl), or its conjugated base, the hypochlorite ion (ClO-). It was confirmed in this study that gold electrode exhibited very large reductive currents as well as good stability compared with platinum and glassy carbon electrodes in the pH range of 4-8. Based on the electrochemical sensors with gold electrode, the present study developed a portable miniaturized FIA system for on-site monitoring of residual chlorine in environmental samples. As for the purpose of on-site determination, miniaturization of the potentiostat along with a reduction in the complexity of the chip, low power consumption and a high dynamic range was developed in the current work. The potentiostat was built using an embedded controller microprocessor, an A/D converter a D/A converter, and operational amplifiers. It is available operated by a battery for a video camcorder (Sony NP-F550, 7.2 V 1500 mA/H). The size of the potentiostat is 150×100×40 mm and weight is only 350 g. The electrochemical measurements were controlled by a notebook computer and a laboratory-written software package via an RS-232C interface. It was confirmed that the amperometric response increased in proportion to the chlorine concentration up to 5μg/ml, and the detection limit for chlorine was 0.05 μg/ml. Besides a drastic reduction the size of the analytical system, such miniaturization achieved the advantages of increased speed, minimal mobile-phase consumption, and high sensitivity. The proposed method was successfully applied to the determination of residual chlorine in samples of pool water and tap water. The results were well agreed with those obtained by the N,N-diethyl-p-phenylenediamine (DPD) photometric method.The electrochemical behavior of trace chlorine was also studied in the presence of DPD at glassy carbon electrode by square wave voltammetry. In the lower pH value, a new reduction wave (+0.4 V vs Ag/AgCl) was observed, which is closely followed by the reduction of DPD (+0.5 V vs Ag/AgCl). The new peak at ca. +0.4 V was suggested to be generated by chlorinated product of DPD which is in proportion to the concentration of chlorine. But this peak was seriously overlapped by the background of DPD when the concentration of chlorine is low. In this study, signals-ratio method combined with wavelet transform was proposed for the resolution of a weak voltanunteric signal overlapped by other coexisted components. With the proposed method, the overlapped voltammetric peaks can be well separated and thereby the chlorine at trace level could be determined in a linear range of 0 to 100 μM with a detection limit of 0.5 μM. The advantages of proposed method are sensitive and free of some oxidant interthrences which could be a problem in DPD colorimetric method. The mechanism and the application in determination of real samples are now in progress. More... »

URL

https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-15550067

Related SciGraph Publications

JSON-LD is the canonical representation for SciGraph data.

TIP: You can open this SciGraph record using an external JSON-LD service: JSON-LD Playground Google SDTT

[
  {
    "@context": "https://springernature.github.io/scigraph/jsonld/sgcontext.json", 
    "about": [
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/2203", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "type": "DefinedTerm"
      }, 
      {
        "id": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/2203", 
        "inDefinedTermSet": "http://purl.org/au-research/vocabulary/anzsrc-for/2008/", 
        "type": "DefinedTerm"
      }
    ], 
    "amount": {
      "currency": "JPY", 
      "type": "MonetaryAmount", 
      "value": "3100000"
    }, 
    "description": "Chlorine in aqueous solutions is used for a number of purposes, such as disinfection and bleaching, and also as a powerful oxidizing agent in various manufacturing processes. It is known that chlorine is highly toxic, and additionally it can further react with other substances, such as phenols, in environment to produce chlorophenols, which are suspected to be carcinogens. Thus, the development of the new methods and devices for the reliable and continuous measurement of residual chlorine at trace levels had been conducted in the present work.Residual chlorine in water is generally present in the fibrin of hypochlorous acid (HOCl), or its conjugated base, the hypochlorite ion (ClO-). It was confirmed in this study that gold electrode exhibited very large reductive currents as well as good stability compared with platinum and glassy carbon electrodes in the pH range of 4-8. Based on the electrochemical sensors with gold electrode, the present study developed a portable miniaturized FIA system for on-site monitoring of residual chlorine in environmental samples. As for the purpose of on-site determination, miniaturization of the potentiostat along with a reduction in the complexity of the chip, low power consumption and a high dynamic range was developed in the current work. The potentiostat was built using an embedded controller microprocessor, an A/D converter a D/A converter, and operational amplifiers. It is available operated by a battery for a video camcorder (Sony NP-F550, 7.2 V 1500 mA/H). The size of the potentiostat is 150\u00d7100\u00d740 mm and weight is only 350 g. The electrochemical measurements were controlled by a notebook computer and a laboratory-written software package via an RS-232C interface. It was confirmed that the amperometric response increased in proportion to the chlorine concentration up to 5\u03bcg/ml, and the detection limit for chlorine was 0.05 \u03bcg/ml. Besides a drastic reduction the size of the analytical system, such miniaturization achieved the advantages of increased speed, minimal mobile-phase consumption, and high sensitivity. The proposed method was successfully applied to the determination of residual chlorine in samples of pool water and tap water. The results were well agreed with those obtained by the N,N-diethyl-p-phenylenediamine (DPD) photometric method.The electrochemical behavior of trace chlorine was also studied in the presence of DPD at glassy carbon electrode by square wave voltammetry. In the lower pH value, a new reduction wave (+0.4 V vs Ag/AgCl) was observed, which is closely followed by the reduction of DPD (+0.5 V vs Ag/AgCl). The new peak at ca. +0.4 V was suggested to be generated by chlorinated product of DPD which is in proportion to the concentration of chlorine. But this peak was seriously overlapped by the background of DPD when the concentration of chlorine is low. In this study, signals-ratio method combined with wavelet transform was proposed for the resolution of a weak voltanunteric signal overlapped by other coexisted components. With the proposed method, the overlapped voltammetric peaks can be well separated and thereby the chlorine at trace level could be determined in a linear range of 0 to 100 \u03bcM with a detection limit of 0.5 \u03bcM. The advantages of proposed method are sensitive and free of some oxidant interthrences which could be a problem in DPD colorimetric method. The mechanism and the application in determination of real samples are now in progress.", 
    "endDate": "2004-12-31T00:00:00Z", 
    "funder": {
      "id": "https://www.grid.ac/institutes/grid.54432.34", 
      "type": "Organization"
    }, 
    "id": "sg:grant.5842661", 
    "identifier": [
      {
        "name": "dimensions_id", 
        "type": "PropertyValue", 
        "value": [
          "5842661"
        ]
      }, 
      {
        "name": "kaken_id", 
        "type": "PropertyValue", 
        "value": [
          "15550067"
        ]
      }
    ], 
    "inLanguage": [
      "en"
    ], 
    "keywords": [
      "DPD colorimetric method", 
      "portable miniaturized FIA system", 
      "RS-232C interface", 
      "study", 
      "water", 
      "G.", 
      "5\u03bcg/", 
      "aqueous solution", 
      "hypochlorous acid", 
      "new method", 
      "\u03bcm", 
      "drastic reduction", 
      "high sensitivity", 
      "hypochlorite ion", 
      "new reduction wave", 
      "converter", 
      "trace chlorine", 
      "linear range", 
      "development", 
      "various manufacturing processes", 
      "chlorine", 
      "advantages", 
      "site monitoring", 
      "device", 
      "size", 
      "chlorophenols", 
      "detection limit", 
      "complexity", 
      "reduction", 
      "laboratory", 
      "electrochemical behavior", 
      "phenol", 
      "speed", 
      "site determination", 
      "high dynamic range", 
      "fibrin", 
      "residual chlorine", 
      "application", 
      "ClO-", 
      "diethyl", 
      "proposed method", 
      "good stability", 
      "pool water", 
      "amperometric response", 
      "controller microprocessor", 
      "carcinogens", 
      "analytical system", 
      "bleaching", 
      "signals-ratio method", 
      "platinum", 
      "minimal mobile-phase consumption", 
      "environmental samples", 
      "BACKGROUND", 
      "pH range", 
      "conjugated base", 
      "peak", 
      "results", 
      "disinfection", 
      "chlorinated products", 
      "\u03bcM.", 
      "resolution", 
      "video camcorder", 
      "environment", 
      "purpose", 
      "chip", 
      "wavelet transform", 
      "miniaturized analytical systems", 
      "voltammetric peaks", 
      "notebook computers", 
      "electrochemical measurements", 
      "METHODS", 
      "number", 
      "tap water", 
      "progress", 
      "samples", 
      "current work", 
      "electrochemical sensor", 
      "presence", 
      "determination", 
      "continuous measurement", 
      "proportion", 
      "Ag/AgCl", 
      "Sony NP-F550", 
      "components", 
      "phenylenediamine", 
      "operational amplifier", 
      "trace levels", 
      "weight", 
      "battery", 
      "Ca", 
      "photometric method", 
      "square wave voltammetry", 
      "new peak", 
      "present work", 
      "low pH values", 
      "\u03bcg/mL", 
      "potentiostat", 
      "RESIDUAL CHLORINE WITH ELECTROCHEMICAL SENSORS", 
      "mm", 
      "large reductive currents", 
      "present study", 
      "chlorine concentration", 
      "real samples", 
      "problem", 
      "powerful oxidizing agent", 
      "glassy carbon electrode", 
      "other substances", 
      "such miniaturization", 
      "concentration", 
      "low power consumption", 
      "miniaturization", 
      "MA/H", 
      "software package", 
      "weak voltanunteric signal", 
      "DPD", 
      "mechanism", 
      "gold electrode", 
      "oxidant interthrences"
    ], 
    "name": "DEVELOPMENT OF MINIATURIZED ANALYTICAL SYSTEM FOR RESIDUAL CHLORINE WITH ELECTROCHEMICAL SENSORS", 
    "recipient": [
      {
        "id": "https://www.grid.ac/institutes/grid.263518.b", 
        "type": "Organization"
      }
    ], 
    "sameAs": [
      "https://app.dimensions.ai/details/grant/grant.5842661"
    ], 
    "sdDataset": "grants", 
    "sdDatePublished": "2019-03-07T11:39", 
    "sdLicense": "https://scigraph.springernature.com/explorer/license/", 
    "sdPublisher": {
      "name": "Springer Nature - SN SciGraph project", 
      "type": "Organization"
    }, 
    "sdSource": "s3://com.uberresearch.data.processor/core_data/20181219_192338/projects/base/kaken_projects_13.xml.gz", 
    "startDate": "2003-01-01T00:00:00Z", 
    "type": "MonetaryGrant", 
    "url": "https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-15550067"
  }
]
 

Download the RDF metadata as:  json-ld nt turtle xml License info

HOW TO GET THIS DATA PROGRAMMATICALLY:

JSON-LD is a popular format for linked data which is fully compatible with JSON.

curl -H 'Accept: application/ld+json' 'https://scigraph.springernature.com/grant.5842661'

N-Triples is a line-based linked data format ideal for batch operations.

curl -H 'Accept: application/n-triples' 'https://scigraph.springernature.com/grant.5842661'

Turtle is a human-readable linked data format.

curl -H 'Accept: text/turtle' 'https://scigraph.springernature.com/grant.5842661'

RDF/XML is a standard XML format for linked data.

curl -H 'Accept: application/rdf+xml' 'https://scigraph.springernature.com/grant.5842661'


 

This table displays all metadata directly associated to this object as RDF triples.

152 TRIPLES      19 PREDICATES      138 URIs      131 LITERALS      4 BLANK NODES

Subject Predicate Object
1 sg:grant.5842661 schema:about anzsrc-for:2203
2 schema:amount Nfa2cedb9e4fe4c359e6c362e347940d7
3 schema:description Chlorine in aqueous solutions is used for a number of purposes, such as disinfection and bleaching, and also as a powerful oxidizing agent in various manufacturing processes. It is known that chlorine is highly toxic, and additionally it can further react with other substances, such as phenols, in environment to produce chlorophenols, which are suspected to be carcinogens. Thus, the development of the new methods and devices for the reliable and continuous measurement of residual chlorine at trace levels had been conducted in the present work.Residual chlorine in water is generally present in the fibrin of hypochlorous acid (HOCl), or its conjugated base, the hypochlorite ion (ClO-). It was confirmed in this study that gold electrode exhibited very large reductive currents as well as good stability compared with platinum and glassy carbon electrodes in the pH range of 4-8. Based on the electrochemical sensors with gold electrode, the present study developed a portable miniaturized FIA system for on-site monitoring of residual chlorine in environmental samples. As for the purpose of on-site determination, miniaturization of the potentiostat along with a reduction in the complexity of the chip, low power consumption and a high dynamic range was developed in the current work. The potentiostat was built using an embedded controller microprocessor, an A/D converter a D/A converter, and operational amplifiers. It is available operated by a battery for a video camcorder (Sony NP-F550, 7.2 V 1500 mA/H). The size of the potentiostat is 150×100×40 mm and weight is only 350 g. The electrochemical measurements were controlled by a notebook computer and a laboratory-written software package via an RS-232C interface. It was confirmed that the amperometric response increased in proportion to the chlorine concentration up to 5μg/ml, and the detection limit for chlorine was 0.05 μg/ml. Besides a drastic reduction the size of the analytical system, such miniaturization achieved the advantages of increased speed, minimal mobile-phase consumption, and high sensitivity. The proposed method was successfully applied to the determination of residual chlorine in samples of pool water and tap water. The results were well agreed with those obtained by the N,N-diethyl-p-phenylenediamine (DPD) photometric method.The electrochemical behavior of trace chlorine was also studied in the presence of DPD at glassy carbon electrode by square wave voltammetry. In the lower pH value, a new reduction wave (+0.4 V vs Ag/AgCl) was observed, which is closely followed by the reduction of DPD (+0.5 V vs Ag/AgCl). The new peak at ca. +0.4 V was suggested to be generated by chlorinated product of DPD which is in proportion to the concentration of chlorine. But this peak was seriously overlapped by the background of DPD when the concentration of chlorine is low. In this study, signals-ratio method combined with wavelet transform was proposed for the resolution of a weak voltanunteric signal overlapped by other coexisted components. With the proposed method, the overlapped voltammetric peaks can be well separated and thereby the chlorine at trace level could be determined in a linear range of 0 to 100 μM with a detection limit of 0.5 μM. The advantages of proposed method are sensitive and free of some oxidant interthrences which could be a problem in DPD colorimetric method. The mechanism and the application in determination of real samples are now in progress.
4 schema:endDate 2004-12-31T00:00:00Z
5 schema:funder https://www.grid.ac/institutes/grid.54432.34
6 schema:identifier N3185a4238086424094bf1ddce2f2575a
7 Needaab72491f4caba6826f6385dd9df7
8 schema:inLanguage en
9 schema:keywords 5μg/
10 Ag/AgCl
11 BACKGROUND
12 Ca
13 ClO-
14 DPD
15 DPD colorimetric method
16 G.
17 MA/H
18 METHODS
19 RESIDUAL CHLORINE WITH ELECTROCHEMICAL SENSORS
20 RS-232C interface
21 Sony NP-F550
22 advantages
23 amperometric response
24 analytical system
25 application
26 aqueous solution
27 battery
28 bleaching
29 carcinogens
30 chip
31 chlorinated products
32 chlorine
33 chlorine concentration
34 chlorophenols
35 complexity
36 components
37 concentration
38 conjugated base
39 continuous measurement
40 controller microprocessor
41 converter
42 current work
43 detection limit
44 determination
45 development
46 device
47 diethyl
48 disinfection
49 drastic reduction
50 electrochemical behavior
51 electrochemical measurements
52 electrochemical sensor
53 environment
54 environmental samples
55 fibrin
56 glassy carbon electrode
57 gold electrode
58 good stability
59 high dynamic range
60 high sensitivity
61 hypochlorite ion
62 hypochlorous acid
63 laboratory
64 large reductive currents
65 linear range
66 low pH values
67 low power consumption
68 mechanism
69 miniaturization
70 miniaturized analytical systems
71 minimal mobile-phase consumption
72 mm
73 new method
74 new peak
75 new reduction wave
76 notebook computers
77 number
78 operational amplifier
79 other substances
80 oxidant interthrences
81 pH range
82 peak
83 phenol
84 phenylenediamine
85 photometric method
86 platinum
87 pool water
88 portable miniaturized FIA system
89 potentiostat
90 powerful oxidizing agent
91 presence
92 present study
93 present work
94 problem
95 progress
96 proportion
97 proposed method
98 purpose
99 real samples
100 reduction
101 residual chlorine
102 resolution
103 results
104 samples
105 signals-ratio method
106 site determination
107 site monitoring
108 size
109 software package
110 speed
111 square wave voltammetry
112 study
113 such miniaturization
114 tap water
115 trace chlorine
116 trace levels
117 various manufacturing processes
118 video camcorder
119 voltammetric peaks
120 water
121 wavelet transform
122 weak voltanunteric signal
123 weight
124 μM.
125 μg/mL
126 μm
127 schema:name DEVELOPMENT OF MINIATURIZED ANALYTICAL SYSTEM FOR RESIDUAL CHLORINE WITH ELECTROCHEMICAL SENSORS
128 schema:recipient https://www.grid.ac/institutes/grid.263518.b
129 schema:sameAs https://app.dimensions.ai/details/grant/grant.5842661
130 schema:sdDatePublished 2019-03-07T11:39
131 schema:sdLicense https://scigraph.springernature.com/explorer/license/
132 schema:sdPublisher N206cc0dc08cf42cc9a1cbbfc50543f34
133 schema:startDate 2003-01-01T00:00:00Z
134 schema:url https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-15550067
135 sgo:license sg:explorer/license/
136 sgo:sdDataset grants
137 rdf:type schema:MonetaryGrant
138 N206cc0dc08cf42cc9a1cbbfc50543f34 schema:name Springer Nature - SN SciGraph project
139 rdf:type schema:Organization
140 N3185a4238086424094bf1ddce2f2575a schema:name dimensions_id
141 schema:value 5842661
142 rdf:type schema:PropertyValue
143 Needaab72491f4caba6826f6385dd9df7 schema:name kaken_id
144 schema:value 15550067
145 rdf:type schema:PropertyValue
146 Nfa2cedb9e4fe4c359e6c362e347940d7 schema:currency JPY
147 schema:value 3100000
148 rdf:type schema:MonetaryAmount
149 anzsrc-for:2203 schema:inDefinedTermSet anzsrc-for:
150 rdf:type schema:DefinedTerm
151 https://www.grid.ac/institutes/grid.263518.b schema:Organization
152 https://www.grid.ac/institutes/grid.54432.34 schema:Organization
 




Preview window. Press ESC to close (or click here)


...